Cargando…

Which Comes First in Sports Vision Training: The Software or the Hardware Update? Utility of Electrophysiological Measures in Monitoring Specialized Visual Training in Youth Athletes

In the present study we combined popular methods of sports vision training (SVT) with traditional oculomotor protocols of Optometric Vision Therapy (OVT) and electrophysiological indexes of EEG and VEP activity to monitor training progress and changes in performance of youth ice hockey players witho...

Descripción completa

Detalles Bibliográficos
Autores principales: Poltavski, Dmitri, Biberdorf, David, Praus Poltavski, Carolina
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8527177/
https://www.ncbi.nlm.nih.gov/pubmed/34690722
http://dx.doi.org/10.3389/fnhum.2021.732303
_version_ 1784586025160409088
author Poltavski, Dmitri
Biberdorf, David
Praus Poltavski, Carolina
author_facet Poltavski, Dmitri
Biberdorf, David
Praus Poltavski, Carolina
author_sort Poltavski, Dmitri
collection PubMed
description In the present study we combined popular methods of sports vision training (SVT) with traditional oculomotor protocols of Optometric Vision Therapy (OVT) and electrophysiological indexes of EEG and VEP activity to monitor training progress and changes in performance of youth ice hockey players without the history of concussion. We hypothesized that administration of OVT protocols before SVT training may result in larger performance improvements compared to the reverse order due to the initial strengthening of visual hardware capable of handling greater demands during training of visuomotor integration and information processing skills (visual software). In a cross-over design 53 youth ice hockey players (ages 13–18) were randomly assigned to one of the two training groups. Group one (hardware-software group) completed 5 weeks of oculomotor training first followed by 5 weeks of software training. For group 2 (software-hardware) the order of procedures were reversed. After 10 weeks of training both groups significantly improved their performance on all but one measure of the Nike/Senaptec Sensory station measures. Additionally, the software-hardware training order resulted in significantly lower frontal theta-to-gamma amplitude ratios on the Nike/Senaptec test of Near-Far Quickness as well as in faster P100 latencies. Both training orders also resulted in significant decreases in post-treatment P100 amplitude to transient VEP stimuli as well as decreased theta-gamma ratios for perception span, Go/No-Go and Hand Reaction time. The observed changes in the electrophysiological indexes in the present study are thought to reflect greater efficiency in visual information processing and cognitive resource allocation following 10 weeks of visual training. There is also some evidence of the greater effectiveness of the software-hardware training order possibly due to the improved preparedness of the oculomotor system in the youth athletes for administration of targeted protocols of the Optometric Vision Therapy.
format Online
Article
Text
id pubmed-8527177
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-85271772021-10-21 Which Comes First in Sports Vision Training: The Software or the Hardware Update? Utility of Electrophysiological Measures in Monitoring Specialized Visual Training in Youth Athletes Poltavski, Dmitri Biberdorf, David Praus Poltavski, Carolina Front Hum Neurosci Human Neuroscience In the present study we combined popular methods of sports vision training (SVT) with traditional oculomotor protocols of Optometric Vision Therapy (OVT) and electrophysiological indexes of EEG and VEP activity to monitor training progress and changes in performance of youth ice hockey players without the history of concussion. We hypothesized that administration of OVT protocols before SVT training may result in larger performance improvements compared to the reverse order due to the initial strengthening of visual hardware capable of handling greater demands during training of visuomotor integration and information processing skills (visual software). In a cross-over design 53 youth ice hockey players (ages 13–18) were randomly assigned to one of the two training groups. Group one (hardware-software group) completed 5 weeks of oculomotor training first followed by 5 weeks of software training. For group 2 (software-hardware) the order of procedures were reversed. After 10 weeks of training both groups significantly improved their performance on all but one measure of the Nike/Senaptec Sensory station measures. Additionally, the software-hardware training order resulted in significantly lower frontal theta-to-gamma amplitude ratios on the Nike/Senaptec test of Near-Far Quickness as well as in faster P100 latencies. Both training orders also resulted in significant decreases in post-treatment P100 amplitude to transient VEP stimuli as well as decreased theta-gamma ratios for perception span, Go/No-Go and Hand Reaction time. The observed changes in the electrophysiological indexes in the present study are thought to reflect greater efficiency in visual information processing and cognitive resource allocation following 10 weeks of visual training. There is also some evidence of the greater effectiveness of the software-hardware training order possibly due to the improved preparedness of the oculomotor system in the youth athletes for administration of targeted protocols of the Optometric Vision Therapy. Frontiers Media S.A. 2021-10-06 /pmc/articles/PMC8527177/ /pubmed/34690722 http://dx.doi.org/10.3389/fnhum.2021.732303 Text en Copyright © 2021 Poltavski, Biberdorf and Praus Poltavski. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Human Neuroscience
Poltavski, Dmitri
Biberdorf, David
Praus Poltavski, Carolina
Which Comes First in Sports Vision Training: The Software or the Hardware Update? Utility of Electrophysiological Measures in Monitoring Specialized Visual Training in Youth Athletes
title Which Comes First in Sports Vision Training: The Software or the Hardware Update? Utility of Electrophysiological Measures in Monitoring Specialized Visual Training in Youth Athletes
title_full Which Comes First in Sports Vision Training: The Software or the Hardware Update? Utility of Electrophysiological Measures in Monitoring Specialized Visual Training in Youth Athletes
title_fullStr Which Comes First in Sports Vision Training: The Software or the Hardware Update? Utility of Electrophysiological Measures in Monitoring Specialized Visual Training in Youth Athletes
title_full_unstemmed Which Comes First in Sports Vision Training: The Software or the Hardware Update? Utility of Electrophysiological Measures in Monitoring Specialized Visual Training in Youth Athletes
title_short Which Comes First in Sports Vision Training: The Software or the Hardware Update? Utility of Electrophysiological Measures in Monitoring Specialized Visual Training in Youth Athletes
title_sort which comes first in sports vision training: the software or the hardware update? utility of electrophysiological measures in monitoring specialized visual training in youth athletes
topic Human Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8527177/
https://www.ncbi.nlm.nih.gov/pubmed/34690722
http://dx.doi.org/10.3389/fnhum.2021.732303
work_keys_str_mv AT poltavskidmitri whichcomesfirstinsportsvisiontrainingthesoftwareorthehardwareupdateutilityofelectrophysiologicalmeasuresinmonitoringspecializedvisualtraininginyouthathletes
AT biberdorfdavid whichcomesfirstinsportsvisiontrainingthesoftwareorthehardwareupdateutilityofelectrophysiologicalmeasuresinmonitoringspecializedvisualtraininginyouthathletes
AT prauspoltavskicarolina whichcomesfirstinsportsvisiontrainingthesoftwareorthehardwareupdateutilityofelectrophysiologicalmeasuresinmonitoringspecializedvisualtraininginyouthathletes