Full-Thickness Rotator Cuff Tears Can Be Safely Treated With a Resorbable Bioinductive Bovine Collagen Implant: One-Year Results of a Prospective, Multicenter Registry

PURPOSE: The purpose of this study was to prospectively collect safety and efficacy data in a large group of patients undergoing arthroscopic repair of full-thickness rotator cuff tears augmented with a resorbable bioinductive bovine collagen implant designed to promote healing. METHODS: Seventeen c...

Descripción completa

Detalles Bibliográficos
Autores principales: McIntyre, Louis F., McMillan, Sean, Trenhaile, Scott W., Bishai, Shariff K., Bushnell, Brandon D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8527318/
https://www.ncbi.nlm.nih.gov/pubmed/34712984
http://dx.doi.org/10.1016/j.asmr.2021.07.009
_version_ 1784586051801579520
author McIntyre, Louis F.
McMillan, Sean
Trenhaile, Scott W.
Bishai, Shariff K.
Bushnell, Brandon D.
author_facet McIntyre, Louis F.
McMillan, Sean
Trenhaile, Scott W.
Bishai, Shariff K.
Bushnell, Brandon D.
author_sort McIntyre, Louis F.
collection PubMed
description PURPOSE: The purpose of this study was to prospectively collect safety and efficacy data in a large group of patients undergoing arthroscopic repair of full-thickness rotator cuff tears augmented with a resorbable bioinductive bovine collagen implant designed to promote healing. METHODS: Seventeen centers across the United States enrolled patients in an institutional review board-approved registry to collect outcomes data on the implant. Patients undergoing surgical management of full-thickness rotator cuff tears augmented with the implant were enrolled. Inclusion criteria were age of ≥21 years, willingness to participate and the ability to read and speak English. Exclusion criteria included hypersensitivity to bovine-derived products. Patients were assessed before and after surgery at up to 1 year with outcomes including the single-assessment numeric evaluation (SANE), Veterans RAND 12-Item (VR-12) mental components and physical components (VR-12 PCS), American Shoulder and Elbow Surgeons (ASES), and Western Ontario Rotator Cuff (WORC) outcome measures. Ad hoc analyses were performed to compare these outcomes at all time points depending on tear size (small/medium vs large/massive). Serious complications were collected. RESULTS: Of 210 patients enrolled, 192 had 1-year follow-up data available. The patients experienced statistically significant improvement between baseline and 1 year for mean SANE, VR-12 PCS, ASES, and WORC scores (40.0-82.0, 33.5-47.3, 46.2-87.8, and 36.2-81.0, respectively; P < .001 for all results). Ad-hoc analysis demonstrated that similar results were obtained at 1 year regardless of tear size. Twenty patients (10.4%) experienced serious complications (10.4%), including revision surgery (n = 18), proximal humerus fracture/partial subscapularis tear resulting from multiple falls (n = 1), and adhesive capsulitis (n = 1). CONCLUSIONS: The safety and efficacy of a bioinductive implant in the surgical management of full-thickness rotator cuff tears at 1 year was shown in this study. Implant efficacy appears to be comparable regardless of the underlying tear size. LEVEL OF EVIDENCE: Level IV, therapeutic case series.
format Online
Article
Text
id pubmed-8527318
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-85273182021-10-27 Full-Thickness Rotator Cuff Tears Can Be Safely Treated With a Resorbable Bioinductive Bovine Collagen Implant: One-Year Results of a Prospective, Multicenter Registry McIntyre, Louis F. McMillan, Sean Trenhaile, Scott W. Bishai, Shariff K. Bushnell, Brandon D. Arthrosc Sports Med Rehabil Original Article PURPOSE: The purpose of this study was to prospectively collect safety and efficacy data in a large group of patients undergoing arthroscopic repair of full-thickness rotator cuff tears augmented with a resorbable bioinductive bovine collagen implant designed to promote healing. METHODS: Seventeen centers across the United States enrolled patients in an institutional review board-approved registry to collect outcomes data on the implant. Patients undergoing surgical management of full-thickness rotator cuff tears augmented with the implant were enrolled. Inclusion criteria were age of ≥21 years, willingness to participate and the ability to read and speak English. Exclusion criteria included hypersensitivity to bovine-derived products. Patients were assessed before and after surgery at up to 1 year with outcomes including the single-assessment numeric evaluation (SANE), Veterans RAND 12-Item (VR-12) mental components and physical components (VR-12 PCS), American Shoulder and Elbow Surgeons (ASES), and Western Ontario Rotator Cuff (WORC) outcome measures. Ad hoc analyses were performed to compare these outcomes at all time points depending on tear size (small/medium vs large/massive). Serious complications were collected. RESULTS: Of 210 patients enrolled, 192 had 1-year follow-up data available. The patients experienced statistically significant improvement between baseline and 1 year for mean SANE, VR-12 PCS, ASES, and WORC scores (40.0-82.0, 33.5-47.3, 46.2-87.8, and 36.2-81.0, respectively; P < .001 for all results). Ad-hoc analysis demonstrated that similar results were obtained at 1 year regardless of tear size. Twenty patients (10.4%) experienced serious complications (10.4%), including revision surgery (n = 18), proximal humerus fracture/partial subscapularis tear resulting from multiple falls (n = 1), and adhesive capsulitis (n = 1). CONCLUSIONS: The safety and efficacy of a bioinductive implant in the surgical management of full-thickness rotator cuff tears at 1 year was shown in this study. Implant efficacy appears to be comparable regardless of the underlying tear size. LEVEL OF EVIDENCE: Level IV, therapeutic case series. Elsevier 2021-08-20 /pmc/articles/PMC8527318/ /pubmed/34712984 http://dx.doi.org/10.1016/j.asmr.2021.07.009 Text en © 2021 The Authors https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Original Article
McIntyre, Louis F.
McMillan, Sean
Trenhaile, Scott W.
Bishai, Shariff K.
Bushnell, Brandon D.
Full-Thickness Rotator Cuff Tears Can Be Safely Treated With a Resorbable Bioinductive Bovine Collagen Implant: One-Year Results of a Prospective, Multicenter Registry
title Full-Thickness Rotator Cuff Tears Can Be Safely Treated With a Resorbable Bioinductive Bovine Collagen Implant: One-Year Results of a Prospective, Multicenter Registry
title_full Full-Thickness Rotator Cuff Tears Can Be Safely Treated With a Resorbable Bioinductive Bovine Collagen Implant: One-Year Results of a Prospective, Multicenter Registry
title_fullStr Full-Thickness Rotator Cuff Tears Can Be Safely Treated With a Resorbable Bioinductive Bovine Collagen Implant: One-Year Results of a Prospective, Multicenter Registry
title_full_unstemmed Full-Thickness Rotator Cuff Tears Can Be Safely Treated With a Resorbable Bioinductive Bovine Collagen Implant: One-Year Results of a Prospective, Multicenter Registry
title_short Full-Thickness Rotator Cuff Tears Can Be Safely Treated With a Resorbable Bioinductive Bovine Collagen Implant: One-Year Results of a Prospective, Multicenter Registry
title_sort full-thickness rotator cuff tears can be safely treated with a resorbable bioinductive bovine collagen implant: one-year results of a prospective, multicenter registry
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8527318/
https://www.ncbi.nlm.nih.gov/pubmed/34712984
http://dx.doi.org/10.1016/j.asmr.2021.07.009
work_keys_str_mv AT mcintyrelouisf fullthicknessrotatorcufftearscanbesafelytreatedwitharesorbablebioinductivebovinecollagenimplantoneyearresultsofaprospectivemulticenterregistry
AT mcmillansean fullthicknessrotatorcufftearscanbesafelytreatedwitharesorbablebioinductivebovinecollagenimplantoneyearresultsofaprospectivemulticenterregistry
AT trenhailescottw fullthicknessrotatorcufftearscanbesafelytreatedwitharesorbablebioinductivebovinecollagenimplantoneyearresultsofaprospectivemulticenterregistry
AT bishaishariffk fullthicknessrotatorcufftearscanbesafelytreatedwitharesorbablebioinductivebovinecollagenimplantoneyearresultsofaprospectivemulticenterregistry
AT bushnellbrandond fullthicknessrotatorcufftearscanbesafelytreatedwitharesorbablebioinductivebovinecollagenimplantoneyearresultsofaprospectivemulticenterregistry