Cargando…

Validation of Fitbit Charge 2 Sleep and Heart Rate Estimates Against Polysomnographic Measures in Shift Workers: Naturalistic Study

BACKGROUND: Multisensor fitness trackers offer the ability to longitudinally estimate sleep quality in a home environment with the potential to outperform traditional actigraphy. To benefit from these new tools for objectively assessing sleep for clinical and research purposes, multisensor wearable...

Descripción completa

Detalles Bibliográficos
Autores principales: Stucky, Benjamin, Clark, Ian, Azza, Yasmine, Karlen, Walter, Achermann, Peter, Kleim, Birgit, Landolt, Hans-Peter
Formato: Online Artículo Texto
Lenguaje:English
Publicado: JMIR Publications 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8527385/
https://www.ncbi.nlm.nih.gov/pubmed/34609317
http://dx.doi.org/10.2196/26476
_version_ 1784586065333452800
author Stucky, Benjamin
Clark, Ian
Azza, Yasmine
Karlen, Walter
Achermann, Peter
Kleim, Birgit
Landolt, Hans-Peter
author_facet Stucky, Benjamin
Clark, Ian
Azza, Yasmine
Karlen, Walter
Achermann, Peter
Kleim, Birgit
Landolt, Hans-Peter
author_sort Stucky, Benjamin
collection PubMed
description BACKGROUND: Multisensor fitness trackers offer the ability to longitudinally estimate sleep quality in a home environment with the potential to outperform traditional actigraphy. To benefit from these new tools for objectively assessing sleep for clinical and research purposes, multisensor wearable devices require careful validation against the gold standard of sleep polysomnography (PSG). Naturalistic studies favor validation. OBJECTIVE: This study aims to validate the Fitbit Charge 2 against portable home PSG in a shift-work population composed of 59 first responder police officers and paramedics undergoing shift work. METHODS: A reliable comparison between the two measurements was ensured through the data-driven alignment of a PSG and Fitbit time series that was recorded at night. Epoch-by-epoch analyses and Bland-Altman plots were used to assess sensitivity, specificity, accuracy, the Matthews correlation coefficient, bias, and limits of agreement. RESULTS: Sleep onset and offset, total sleep time, and the durations of rapid eye movement (REM) sleep and non–rapid-eye movement sleep stages N1+N2 and N3 displayed unbiased estimates with nonnegligible limits of agreement. In contrast, the proprietary Fitbit algorithm overestimated REM sleep latency by 29.4 minutes and wakefulness after sleep onset (WASO) by 37.1 minutes. Epoch-by-epoch analyses indicated better specificity than sensitivity, with higher accuracies for WASO (0.82) and REM sleep (0.86) than those for N1+N2 (0.55) and N3 (0.78) sleep. Fitbit heart rate (HR) displayed a small underestimation of 0.9 beats per minute (bpm) and a limited capability to capture sudden HR changes because of the lower time resolution compared to that of PSG. The underestimation was smaller in N2, N3, and REM sleep (0.6-0.7 bpm) than in N1 sleep (1.2 bpm) and wakefulness (1.9 bpm), indicating a state-specific bias. Finally, Fitbit suggested a distribution of all sleep episode durations that was different from that derived from PSG and showed nonbiological discontinuities, indicating the potential limitations of the staging algorithm. CONCLUSIONS: We conclude that by following careful data processing processes, the Fitbit Charge 2 can provide reasonably accurate mean values of sleep and HR estimates in shift workers under naturalistic conditions. Nevertheless, the generally wide limits of agreement hamper the precision of quantifying individual sleep episodes. The value of this consumer-grade multisensor wearable in terms of tackling clinical and research questions could be enhanced with open-source algorithms, raw data access, and the ability to blind participants to their own sleep data.
format Online
Article
Text
id pubmed-8527385
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher JMIR Publications
record_format MEDLINE/PubMed
spelling pubmed-85273852021-11-09 Validation of Fitbit Charge 2 Sleep and Heart Rate Estimates Against Polysomnographic Measures in Shift Workers: Naturalistic Study Stucky, Benjamin Clark, Ian Azza, Yasmine Karlen, Walter Achermann, Peter Kleim, Birgit Landolt, Hans-Peter J Med Internet Res Original Paper BACKGROUND: Multisensor fitness trackers offer the ability to longitudinally estimate sleep quality in a home environment with the potential to outperform traditional actigraphy. To benefit from these new tools for objectively assessing sleep for clinical and research purposes, multisensor wearable devices require careful validation against the gold standard of sleep polysomnography (PSG). Naturalistic studies favor validation. OBJECTIVE: This study aims to validate the Fitbit Charge 2 against portable home PSG in a shift-work population composed of 59 first responder police officers and paramedics undergoing shift work. METHODS: A reliable comparison between the two measurements was ensured through the data-driven alignment of a PSG and Fitbit time series that was recorded at night. Epoch-by-epoch analyses and Bland-Altman plots were used to assess sensitivity, specificity, accuracy, the Matthews correlation coefficient, bias, and limits of agreement. RESULTS: Sleep onset and offset, total sleep time, and the durations of rapid eye movement (REM) sleep and non–rapid-eye movement sleep stages N1+N2 and N3 displayed unbiased estimates with nonnegligible limits of agreement. In contrast, the proprietary Fitbit algorithm overestimated REM sleep latency by 29.4 minutes and wakefulness after sleep onset (WASO) by 37.1 minutes. Epoch-by-epoch analyses indicated better specificity than sensitivity, with higher accuracies for WASO (0.82) and REM sleep (0.86) than those for N1+N2 (0.55) and N3 (0.78) sleep. Fitbit heart rate (HR) displayed a small underestimation of 0.9 beats per minute (bpm) and a limited capability to capture sudden HR changes because of the lower time resolution compared to that of PSG. The underestimation was smaller in N2, N3, and REM sleep (0.6-0.7 bpm) than in N1 sleep (1.2 bpm) and wakefulness (1.9 bpm), indicating a state-specific bias. Finally, Fitbit suggested a distribution of all sleep episode durations that was different from that derived from PSG and showed nonbiological discontinuities, indicating the potential limitations of the staging algorithm. CONCLUSIONS: We conclude that by following careful data processing processes, the Fitbit Charge 2 can provide reasonably accurate mean values of sleep and HR estimates in shift workers under naturalistic conditions. Nevertheless, the generally wide limits of agreement hamper the precision of quantifying individual sleep episodes. The value of this consumer-grade multisensor wearable in terms of tackling clinical and research questions could be enhanced with open-source algorithms, raw data access, and the ability to blind participants to their own sleep data. JMIR Publications 2021-10-05 /pmc/articles/PMC8527385/ /pubmed/34609317 http://dx.doi.org/10.2196/26476 Text en ©Benjamin Stucky, Ian Clark, Yasmine Azza, Walter Karlen, Peter Achermann, Birgit Kleim, Hans-Peter Landolt. Originally published in the Journal of Medical Internet Research (https://www.jmir.org), 05.10.2021. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in the Journal of Medical Internet Research, is properly cited. The complete bibliographic information, a link to the original publication on https://www.jmir.org/, as well as this copyright and license information must be included.
spellingShingle Original Paper
Stucky, Benjamin
Clark, Ian
Azza, Yasmine
Karlen, Walter
Achermann, Peter
Kleim, Birgit
Landolt, Hans-Peter
Validation of Fitbit Charge 2 Sleep and Heart Rate Estimates Against Polysomnographic Measures in Shift Workers: Naturalistic Study
title Validation of Fitbit Charge 2 Sleep and Heart Rate Estimates Against Polysomnographic Measures in Shift Workers: Naturalistic Study
title_full Validation of Fitbit Charge 2 Sleep and Heart Rate Estimates Against Polysomnographic Measures in Shift Workers: Naturalistic Study
title_fullStr Validation of Fitbit Charge 2 Sleep and Heart Rate Estimates Against Polysomnographic Measures in Shift Workers: Naturalistic Study
title_full_unstemmed Validation of Fitbit Charge 2 Sleep and Heart Rate Estimates Against Polysomnographic Measures in Shift Workers: Naturalistic Study
title_short Validation of Fitbit Charge 2 Sleep and Heart Rate Estimates Against Polysomnographic Measures in Shift Workers: Naturalistic Study
title_sort validation of fitbit charge 2 sleep and heart rate estimates against polysomnographic measures in shift workers: naturalistic study
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8527385/
https://www.ncbi.nlm.nih.gov/pubmed/34609317
http://dx.doi.org/10.2196/26476
work_keys_str_mv AT stuckybenjamin validationoffitbitcharge2sleepandheartrateestimatesagainstpolysomnographicmeasuresinshiftworkersnaturalisticstudy
AT clarkian validationoffitbitcharge2sleepandheartrateestimatesagainstpolysomnographicmeasuresinshiftworkersnaturalisticstudy
AT azzayasmine validationoffitbitcharge2sleepandheartrateestimatesagainstpolysomnographicmeasuresinshiftworkersnaturalisticstudy
AT karlenwalter validationoffitbitcharge2sleepandheartrateestimatesagainstpolysomnographicmeasuresinshiftworkersnaturalisticstudy
AT achermannpeter validationoffitbitcharge2sleepandheartrateestimatesagainstpolysomnographicmeasuresinshiftworkersnaturalisticstudy
AT kleimbirgit validationoffitbitcharge2sleepandheartrateestimatesagainstpolysomnographicmeasuresinshiftworkersnaturalisticstudy
AT landolthanspeter validationoffitbitcharge2sleepandheartrateestimatesagainstpolysomnographicmeasuresinshiftworkersnaturalisticstudy