Cargando…
Polymethyl methacrylate cure time in simulated in vivo total knee arthroplasty versus in vitro conditions
BACKGROUND: The present means of confirming the cure of intra-operative polymethyl methacrylate (PMMA) cement are to wait for the remainder cement to harden. To our knowledge, there is no available technique to determine the precise moment of cure for in-vivo cement beneath the tibial tray. This stu...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8527682/ https://www.ncbi.nlm.nih.gov/pubmed/34670592 http://dx.doi.org/10.1186/s13018-021-02790-y |
_version_ | 1784586118584336384 |
---|---|
author | Funk, Daniel A. Nguyen, Quang-Viet Swank, Michael |
author_facet | Funk, Daniel A. Nguyen, Quang-Viet Swank, Michael |
author_sort | Funk, Daniel A. |
collection | PubMed |
description | BACKGROUND: The present means of confirming the cure of intra-operative polymethyl methacrylate (PMMA) cement are to wait for the remainder cement to harden. To our knowledge, there is no available technique to determine the precise moment of cure for in-vivo cement beneath the tibial tray. This study uses a novel means to determine cement curing time in two environments. One environment represents the operating theater, and the other environment attempts to model cement conditions under the tibial tray during surgery. MATERIALS AND METHODS: We determined the temperature-versus-time plot of cement curing using the following two temperature sensors: one in a simulated implanted tibial tray and another in the remainder cement. We performed 55 tests using dental methyl methacrylate cement mixed in the same ratio as the orthopedic cement. To simulate in vivo conditions, a simulated stainless-steel tibial tray was implanted on a cancellous bone substitute (Sawbones, Vashon Island, WA, USA) using standard cement technique and subsequently placed in a 90°F (32.2 °C) circulating water bath. We positioned a temperature sensor in the cement mantel and positioned a second sensor in a portion of the remaining cement. The temperature from both sensors was measured simultaneously, beginning at 5 min after mixing and continuing for 20 min. The first derivative of the temperature provided the precise curing time for each condition. We analyzed the results of 55 repeated experiments with an independent samples t-test. RESULTS: With the described technique, we were able to accurately determine the moment of cure of the cement beneath the simulated tray. There was a mean difference between cure time of 5 min and 26 s (p value < 0.001) between the two conditions. CONCLUSIONS: We validated that our technique was successful in determining the precise time to cure in two different environments. LEVEL OF EVIDENCE: This was not a clinical trial and did not involve patients as such the level of evidence was Grade A: Consistent 1 and 2. |
format | Online Article Text |
id | pubmed-8527682 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-85276822021-10-25 Polymethyl methacrylate cure time in simulated in vivo total knee arthroplasty versus in vitro conditions Funk, Daniel A. Nguyen, Quang-Viet Swank, Michael J Orthop Surg Res Research Article BACKGROUND: The present means of confirming the cure of intra-operative polymethyl methacrylate (PMMA) cement are to wait for the remainder cement to harden. To our knowledge, there is no available technique to determine the precise moment of cure for in-vivo cement beneath the tibial tray. This study uses a novel means to determine cement curing time in two environments. One environment represents the operating theater, and the other environment attempts to model cement conditions under the tibial tray during surgery. MATERIALS AND METHODS: We determined the temperature-versus-time plot of cement curing using the following two temperature sensors: one in a simulated implanted tibial tray and another in the remainder cement. We performed 55 tests using dental methyl methacrylate cement mixed in the same ratio as the orthopedic cement. To simulate in vivo conditions, a simulated stainless-steel tibial tray was implanted on a cancellous bone substitute (Sawbones, Vashon Island, WA, USA) using standard cement technique and subsequently placed in a 90°F (32.2 °C) circulating water bath. We positioned a temperature sensor in the cement mantel and positioned a second sensor in a portion of the remaining cement. The temperature from both sensors was measured simultaneously, beginning at 5 min after mixing and continuing for 20 min. The first derivative of the temperature provided the precise curing time for each condition. We analyzed the results of 55 repeated experiments with an independent samples t-test. RESULTS: With the described technique, we were able to accurately determine the moment of cure of the cement beneath the simulated tray. There was a mean difference between cure time of 5 min and 26 s (p value < 0.001) between the two conditions. CONCLUSIONS: We validated that our technique was successful in determining the precise time to cure in two different environments. LEVEL OF EVIDENCE: This was not a clinical trial and did not involve patients as such the level of evidence was Grade A: Consistent 1 and 2. BioMed Central 2021-10-20 /pmc/articles/PMC8527682/ /pubmed/34670592 http://dx.doi.org/10.1186/s13018-021-02790-y Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Funk, Daniel A. Nguyen, Quang-Viet Swank, Michael Polymethyl methacrylate cure time in simulated in vivo total knee arthroplasty versus in vitro conditions |
title | Polymethyl methacrylate cure time in simulated in vivo total knee arthroplasty versus in vitro conditions |
title_full | Polymethyl methacrylate cure time in simulated in vivo total knee arthroplasty versus in vitro conditions |
title_fullStr | Polymethyl methacrylate cure time in simulated in vivo total knee arthroplasty versus in vitro conditions |
title_full_unstemmed | Polymethyl methacrylate cure time in simulated in vivo total knee arthroplasty versus in vitro conditions |
title_short | Polymethyl methacrylate cure time in simulated in vivo total knee arthroplasty versus in vitro conditions |
title_sort | polymethyl methacrylate cure time in simulated in vivo total knee arthroplasty versus in vitro conditions |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8527682/ https://www.ncbi.nlm.nih.gov/pubmed/34670592 http://dx.doi.org/10.1186/s13018-021-02790-y |
work_keys_str_mv | AT funkdaniela polymethylmethacrylatecuretimeinsimulatedinvivototalkneearthroplastyversusinvitroconditions AT nguyenquangviet polymethylmethacrylatecuretimeinsimulatedinvivototalkneearthroplastyversusinvitroconditions AT swankmichael polymethylmethacrylatecuretimeinsimulatedinvivototalkneearthroplastyversusinvitroconditions |