Cargando…

Robust Evaluation of Ultraviolet-C Sensitivity for SARS-CoV-2 and Surrogate Coronaviruses

UV light, more specifically UV-C light at a wavelength of 254 nm, is often used to disinfect surfaces, air, and liquids. In early 2020, at the cusp of the COVID-19 pandemic, UV light was identified as an efficient means of eliminating coronaviruses; however, the variability in published sensitivity...

Descripción completa

Detalles Bibliográficos
Autores principales: Boegel, S. J., Gabriel, M., Sasges, M., Petri, B., D’Agostino, M. R., Zhang, A., Ang, J. C., Miller, M. S., Meunier, S. M., Aucoin, M. G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Society for Microbiology 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8528122/
https://www.ncbi.nlm.nih.gov/pubmed/34668746
http://dx.doi.org/10.1128/Spectrum.00537-21
_version_ 1784586196573224960
author Boegel, S. J.
Gabriel, M.
Sasges, M.
Petri, B.
D’Agostino, M. R.
Zhang, A.
Ang, J. C.
Miller, M. S.
Meunier, S. M.
Aucoin, M. G.
author_facet Boegel, S. J.
Gabriel, M.
Sasges, M.
Petri, B.
D’Agostino, M. R.
Zhang, A.
Ang, J. C.
Miller, M. S.
Meunier, S. M.
Aucoin, M. G.
author_sort Boegel, S. J.
collection PubMed
description UV light, more specifically UV-C light at a wavelength of 254 nm, is often used to disinfect surfaces, air, and liquids. In early 2020, at the cusp of the COVID-19 pandemic, UV light was identified as an efficient means of eliminating coronaviruses; however, the variability in published sensitivity data is evidence of the need for experimental rigor to accurately quantify the effectiveness of this technique. In the current study, reliable and reproducible UV techniques have been adopted, including accurate measurement of light intensity, consideration of fluid UV absorbance, and confirmation of uniform dose delivery, including dose verification using an established biological target (T1UV bacteriophage) and a resistant recombinant virus (baculovirus). The experimental results establish the UV sensitivity of SARS-CoV-2, HCoV-229E, HCoV-OC43, and mouse hepatitis virus (MHV) and highlight the potential for surrogate viruses for disinfection studies. All four coronaviruses were found to be easily inactivated by 254 nm irradiation, with UV sensitivities of 1.7, 1.8, 1.7, and 1.2 mJ/cm(2)/log(10) reduction for SARS-CoV-2, HCoV-229E, HCoV-OC43, and MHV, respectively. Similar UV sensitivities for these species demonstrate the capacity for HCoV-OC43, HCoV-229E, and MHV to be considered surrogates for SARS-CoV-2 in UV-inactivation studies, greatly reducing hazards and simplifying procedures for future experimental studies. IMPORTANCE Disinfection of SARS-CoV-2 is of particular importance due to the global COVID-19 pandemic. UV-C irradiation is a compelling disinfection technique because it can be applied to surfaces, air, and water and is commonly used in drinking water and wastewater treatment facilities. UV inactivation depends on the dose received by an organism, regardless of the intensity of the light source or the optical properties of the medium in which it is suspended. The 254 nm irradiation sensitivity was accurately determined using benchmark methodology and a collimated beam apparatus for four coronaviruses (SARS-CoV-2, HCoV-229E, HCoV-OC43, and MHV), a surrogate indicator organism (T1UV), and a resistant recombinant virus (baculovirus vector). Considering the light distribution across the sample surface, the attenuation of light intensity with fluid depth, the optical absorbance of the fluid, and the sample uniformity due to mixing enable accurate measurement of the fundamental inactivation kinetics and UV sensitivity.
format Online
Article
Text
id pubmed-8528122
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher American Society for Microbiology
record_format MEDLINE/PubMed
spelling pubmed-85281222021-11-08 Robust Evaluation of Ultraviolet-C Sensitivity for SARS-CoV-2 and Surrogate Coronaviruses Boegel, S. J. Gabriel, M. Sasges, M. Petri, B. D’Agostino, M. R. Zhang, A. Ang, J. C. Miller, M. S. Meunier, S. M. Aucoin, M. G. Microbiol Spectr Research Article UV light, more specifically UV-C light at a wavelength of 254 nm, is often used to disinfect surfaces, air, and liquids. In early 2020, at the cusp of the COVID-19 pandemic, UV light was identified as an efficient means of eliminating coronaviruses; however, the variability in published sensitivity data is evidence of the need for experimental rigor to accurately quantify the effectiveness of this technique. In the current study, reliable and reproducible UV techniques have been adopted, including accurate measurement of light intensity, consideration of fluid UV absorbance, and confirmation of uniform dose delivery, including dose verification using an established biological target (T1UV bacteriophage) and a resistant recombinant virus (baculovirus). The experimental results establish the UV sensitivity of SARS-CoV-2, HCoV-229E, HCoV-OC43, and mouse hepatitis virus (MHV) and highlight the potential for surrogate viruses for disinfection studies. All four coronaviruses were found to be easily inactivated by 254 nm irradiation, with UV sensitivities of 1.7, 1.8, 1.7, and 1.2 mJ/cm(2)/log(10) reduction for SARS-CoV-2, HCoV-229E, HCoV-OC43, and MHV, respectively. Similar UV sensitivities for these species demonstrate the capacity for HCoV-OC43, HCoV-229E, and MHV to be considered surrogates for SARS-CoV-2 in UV-inactivation studies, greatly reducing hazards and simplifying procedures for future experimental studies. IMPORTANCE Disinfection of SARS-CoV-2 is of particular importance due to the global COVID-19 pandemic. UV-C irradiation is a compelling disinfection technique because it can be applied to surfaces, air, and water and is commonly used in drinking water and wastewater treatment facilities. UV inactivation depends on the dose received by an organism, regardless of the intensity of the light source or the optical properties of the medium in which it is suspended. The 254 nm irradiation sensitivity was accurately determined using benchmark methodology and a collimated beam apparatus for four coronaviruses (SARS-CoV-2, HCoV-229E, HCoV-OC43, and MHV), a surrogate indicator organism (T1UV), and a resistant recombinant virus (baculovirus vector). Considering the light distribution across the sample surface, the attenuation of light intensity with fluid depth, the optical absorbance of the fluid, and the sample uniformity due to mixing enable accurate measurement of the fundamental inactivation kinetics and UV sensitivity. American Society for Microbiology 2021-10-20 /pmc/articles/PMC8528122/ /pubmed/34668746 http://dx.doi.org/10.1128/Spectrum.00537-21 Text en Copyright © 2021 Boegel et al. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution 4.0 International license (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Research Article
Boegel, S. J.
Gabriel, M.
Sasges, M.
Petri, B.
D’Agostino, M. R.
Zhang, A.
Ang, J. C.
Miller, M. S.
Meunier, S. M.
Aucoin, M. G.
Robust Evaluation of Ultraviolet-C Sensitivity for SARS-CoV-2 and Surrogate Coronaviruses
title Robust Evaluation of Ultraviolet-C Sensitivity for SARS-CoV-2 and Surrogate Coronaviruses
title_full Robust Evaluation of Ultraviolet-C Sensitivity for SARS-CoV-2 and Surrogate Coronaviruses
title_fullStr Robust Evaluation of Ultraviolet-C Sensitivity for SARS-CoV-2 and Surrogate Coronaviruses
title_full_unstemmed Robust Evaluation of Ultraviolet-C Sensitivity for SARS-CoV-2 and Surrogate Coronaviruses
title_short Robust Evaluation of Ultraviolet-C Sensitivity for SARS-CoV-2 and Surrogate Coronaviruses
title_sort robust evaluation of ultraviolet-c sensitivity for sars-cov-2 and surrogate coronaviruses
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8528122/
https://www.ncbi.nlm.nih.gov/pubmed/34668746
http://dx.doi.org/10.1128/Spectrum.00537-21
work_keys_str_mv AT boegelsj robustevaluationofultravioletcsensitivityforsarscov2andsurrogatecoronaviruses
AT gabrielm robustevaluationofultravioletcsensitivityforsarscov2andsurrogatecoronaviruses
AT sasgesm robustevaluationofultravioletcsensitivityforsarscov2andsurrogatecoronaviruses
AT petrib robustevaluationofultravioletcsensitivityforsarscov2andsurrogatecoronaviruses
AT dagostinomr robustevaluationofultravioletcsensitivityforsarscov2andsurrogatecoronaviruses
AT zhanga robustevaluationofultravioletcsensitivityforsarscov2andsurrogatecoronaviruses
AT angjc robustevaluationofultravioletcsensitivityforsarscov2andsurrogatecoronaviruses
AT millerms robustevaluationofultravioletcsensitivityforsarscov2andsurrogatecoronaviruses
AT meuniersm robustevaluationofultravioletcsensitivityforsarscov2andsurrogatecoronaviruses
AT aucoinmg robustevaluationofultravioletcsensitivityforsarscov2andsurrogatecoronaviruses