Cargando…

Test-Retest Reliability of Short-Interval Intracortical Inhibition Assessed by Threshold-Tracking and Automated Conventional Techniques

Two novel short-interval intracortical inhibition (SICI) protocols, assessing SICI across a range of interstimulus intervals (ISIs) using either parallel threshold-tracking transcranial magnetic stimulation (TT-TMS) or automated conventional TMS (cTMS), were recently introduced. However, the test-re...

Descripción completa

Detalles Bibliográficos
Autores principales: Nielsen, Christina S.-Z., Samusyte, Gintaute, Pugdahl, Kirsten, Blicher, Jakob U., Fuglsang-Frederiksen, Anders, Cengiz, Bülent, Tankisi, Hatice
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Society for Neuroscience 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8528507/
https://www.ncbi.nlm.nih.gov/pubmed/34561238
http://dx.doi.org/10.1523/ENEURO.0103-21.2021
_version_ 1784586262777167872
author Nielsen, Christina S.-Z.
Samusyte, Gintaute
Pugdahl, Kirsten
Blicher, Jakob U.
Fuglsang-Frederiksen, Anders
Cengiz, Bülent
Tankisi, Hatice
author_facet Nielsen, Christina S.-Z.
Samusyte, Gintaute
Pugdahl, Kirsten
Blicher, Jakob U.
Fuglsang-Frederiksen, Anders
Cengiz, Bülent
Tankisi, Hatice
author_sort Nielsen, Christina S.-Z.
collection PubMed
description Two novel short-interval intracortical inhibition (SICI) protocols, assessing SICI across a range of interstimulus intervals (ISIs) using either parallel threshold-tracking transcranial magnetic stimulation (TT-TMS) or automated conventional TMS (cTMS), were recently introduced. However, the test-retest reliability of these protocols has not been investigated, which is important if they are to be introduced in the clinic. SICI was recorded in 18 healthy subjects using TT-TMS (T-SICI) and cTMS (A-SICI). All subjects were examined at four identical sessions, i.e., morning and afternoon sessions on 2 d, 5–7 d apart. Both SICI protocols were performed twice at each session by the same observer. In one of the sessions, another observer performed additional examinations. Neither intraobserver nor interobserver measures of SICI differed significantly between examinations, except for T-SICI at ISI 3 ms (p = 0.00035) and A-SICI at ISI 2.5 ms (p = 0.0103). Intraday reliability was poor-to-good for A-SICI and moderate-to-good for T-SICI. Interday and interobserver reliabilities of T-SICI and A-SICI were moderate-to-good. Although between-subject variation constituted most of the total variation, SICI repeatability in an individual subject was poor. The two SICI protocols showed no considerable systematic bias across sessions and had a comparable test-retest reliability profile. Findings from the present study suggest that both SICI protocols may be reliably and reproducibly employed in research studies, but should be used with caution for individual decision-making in clinical settings. Studies exploring reliability in patient cohorts are warranted to investigate the clinical utility of these two SICI protocols.
format Online
Article
Text
id pubmed-8528507
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Society for Neuroscience
record_format MEDLINE/PubMed
spelling pubmed-85285072021-10-21 Test-Retest Reliability of Short-Interval Intracortical Inhibition Assessed by Threshold-Tracking and Automated Conventional Techniques Nielsen, Christina S.-Z. Samusyte, Gintaute Pugdahl, Kirsten Blicher, Jakob U. Fuglsang-Frederiksen, Anders Cengiz, Bülent Tankisi, Hatice eNeuro Research Article: Methods/New Tools Two novel short-interval intracortical inhibition (SICI) protocols, assessing SICI across a range of interstimulus intervals (ISIs) using either parallel threshold-tracking transcranial magnetic stimulation (TT-TMS) or automated conventional TMS (cTMS), were recently introduced. However, the test-retest reliability of these protocols has not been investigated, which is important if they are to be introduced in the clinic. SICI was recorded in 18 healthy subjects using TT-TMS (T-SICI) and cTMS (A-SICI). All subjects were examined at four identical sessions, i.e., morning and afternoon sessions on 2 d, 5–7 d apart. Both SICI protocols were performed twice at each session by the same observer. In one of the sessions, another observer performed additional examinations. Neither intraobserver nor interobserver measures of SICI differed significantly between examinations, except for T-SICI at ISI 3 ms (p = 0.00035) and A-SICI at ISI 2.5 ms (p = 0.0103). Intraday reliability was poor-to-good for A-SICI and moderate-to-good for T-SICI. Interday and interobserver reliabilities of T-SICI and A-SICI were moderate-to-good. Although between-subject variation constituted most of the total variation, SICI repeatability in an individual subject was poor. The two SICI protocols showed no considerable systematic bias across sessions and had a comparable test-retest reliability profile. Findings from the present study suggest that both SICI protocols may be reliably and reproducibly employed in research studies, but should be used with caution for individual decision-making in clinical settings. Studies exploring reliability in patient cohorts are warranted to investigate the clinical utility of these two SICI protocols. Society for Neuroscience 2021-10-19 /pmc/articles/PMC8528507/ /pubmed/34561238 http://dx.doi.org/10.1523/ENEURO.0103-21.2021 Text en Copyright © 2021 Nielsen et al. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution 4.0 International license (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution and reproduction in any medium provided that the original work is properly attributed.
spellingShingle Research Article: Methods/New Tools
Nielsen, Christina S.-Z.
Samusyte, Gintaute
Pugdahl, Kirsten
Blicher, Jakob U.
Fuglsang-Frederiksen, Anders
Cengiz, Bülent
Tankisi, Hatice
Test-Retest Reliability of Short-Interval Intracortical Inhibition Assessed by Threshold-Tracking and Automated Conventional Techniques
title Test-Retest Reliability of Short-Interval Intracortical Inhibition Assessed by Threshold-Tracking and Automated Conventional Techniques
title_full Test-Retest Reliability of Short-Interval Intracortical Inhibition Assessed by Threshold-Tracking and Automated Conventional Techniques
title_fullStr Test-Retest Reliability of Short-Interval Intracortical Inhibition Assessed by Threshold-Tracking and Automated Conventional Techniques
title_full_unstemmed Test-Retest Reliability of Short-Interval Intracortical Inhibition Assessed by Threshold-Tracking and Automated Conventional Techniques
title_short Test-Retest Reliability of Short-Interval Intracortical Inhibition Assessed by Threshold-Tracking and Automated Conventional Techniques
title_sort test-retest reliability of short-interval intracortical inhibition assessed by threshold-tracking and automated conventional techniques
topic Research Article: Methods/New Tools
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8528507/
https://www.ncbi.nlm.nih.gov/pubmed/34561238
http://dx.doi.org/10.1523/ENEURO.0103-21.2021
work_keys_str_mv AT nielsenchristinasz testretestreliabilityofshortintervalintracorticalinhibitionassessedbythresholdtrackingandautomatedconventionaltechniques
AT samusytegintaute testretestreliabilityofshortintervalintracorticalinhibitionassessedbythresholdtrackingandautomatedconventionaltechniques
AT pugdahlkirsten testretestreliabilityofshortintervalintracorticalinhibitionassessedbythresholdtrackingandautomatedconventionaltechniques
AT blicherjakobu testretestreliabilityofshortintervalintracorticalinhibitionassessedbythresholdtrackingandautomatedconventionaltechniques
AT fuglsangfrederiksenanders testretestreliabilityofshortintervalintracorticalinhibitionassessedbythresholdtrackingandautomatedconventionaltechniques
AT cengizbulent testretestreliabilityofshortintervalintracorticalinhibitionassessedbythresholdtrackingandautomatedconventionaltechniques
AT tankisihatice testretestreliabilityofshortintervalintracorticalinhibitionassessedbythresholdtrackingandautomatedconventionaltechniques