Cargando…

Differentiating PSP from MSA using MR planimetric measurements: a systematic review and meta-analysis

Differential diagnosis of parkinsonian syndromes is considered one of the most challenging in neurology. Quantitative MR planimetric measurements were reported to discriminate between progressive supranuclear palsy (PSP) and non-PSP-parkinsonism. Several studies have used midbrain to pons ratio (M/P...

Descripción completa

Detalles Bibliográficos
Autores principales: Heim, Beatrice, Krismer, Florian, Seppi, Klaus
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Vienna 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8528799/
https://www.ncbi.nlm.nih.gov/pubmed/34105000
http://dx.doi.org/10.1007/s00702-021-02362-8
Descripción
Sumario:Differential diagnosis of parkinsonian syndromes is considered one of the most challenging in neurology. Quantitative MR planimetric measurements were reported to discriminate between progressive supranuclear palsy (PSP) and non-PSP-parkinsonism. Several studies have used midbrain to pons ratio (M/P) and the Magnetic Resonance Parkinsonism Index (MRPI) in distinguishing PSP patients from those with Parkinson's disease. The current meta-analysis aimed to compare the performance of these measures in discriminating PSP from multiple system atrophy (MSA). A systematic MEDLINE review identified 59 out of 2984 studies allowing a calculation of sensitivity and specificity using the MRPI or M/P. Meta-analyses of results were carried out using random effects modelling. To assess study quality and risk of bias, the QUADAS-2 tool was used. Eight studies were suitable for analysis. The meta‐analysis showed a pooled sensitivity and specificity for the MRPI of PSP versus MSA of 79.2% (95% CI 72.7–84.4%) and 91.2% (95% CI 79.5–96.5%), and 84.1% (95% CI 77.2–89.2%) and 89.2% (95% CI 81.8–93.8%), respectively, for the M/P. The QUADAS-2 toolbox revealed a high risk of bias regarding the methodological quality of patient selection and index test, as all patients were seen in a specialized outpatient department without avoiding case control design and no predefined threshold was given regarding MRPI or M/P cut-offs. Planimetric brainstem measurements, in special the MRPI and M/P, yield high diagnostic accuracy for the discrimination of PSP from MSA. However, there is an urgent need for well-designed, prospective validation studies to ameliorate the concerns regarding the risk of bias. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00702-021-02362-8.