Cargando…

Validation of a Portable Whole-Slide Imaging System for Frozen Section Diagnosis

BACKGROUND: Frozen section (FS) diagnosis is one of the promising applications of digital pathology (DP). However, the implementation of an appropriate and economically viable DP solution for FS in routine practice is challenging. The objective of this study was to establish the non-inferiority of w...

Descripción completa

Detalles Bibliográficos
Autores principales: Kaushal, Rajiv Kumar, Rajaganesan, Sathyanarayanan, Rao, Vidya, Sali, Akash, More, Balaji, Desai, Sangeeta B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8529342/
https://www.ncbi.nlm.nih.gov/pubmed/34760330
http://dx.doi.org/10.4103/jpi.jpi_95_20
_version_ 1784586451447447552
author Kaushal, Rajiv Kumar
Rajaganesan, Sathyanarayanan
Rao, Vidya
Sali, Akash
More, Balaji
Desai, Sangeeta B.
author_facet Kaushal, Rajiv Kumar
Rajaganesan, Sathyanarayanan
Rao, Vidya
Sali, Akash
More, Balaji
Desai, Sangeeta B.
author_sort Kaushal, Rajiv Kumar
collection PubMed
description BACKGROUND: Frozen section (FS) diagnosis is one of the promising applications of digital pathology (DP). However, the implementation of an appropriate and economically viable DP solution for FS in routine practice is challenging. The objective of this study was to establish the non-inferiority of whole-slide imaging (WSI) versus optical microscopy (OM) for FS diagnosis using a low cost and portable DP system. MATERIALS AND METHODS: A validation study to investigate the technical performance and diagnostic accuracy of WSI versus OM for FS diagnosis was performed using 60 FS cases[120 slides i.e, 60 hematoxylin and eosin (H & E) and 60 toluidine blue (TOLB)]. The diagnostic concordance, inter- and intra-observer agreement for FS diagnosis by WSI versus OM were recorded. RESULTS: The first time successful scanning rate was 89.1% (107/120). Mean scanning time per slide for H and E and TOLB slide was 1:47 min (range; 0:22–3: 21 min) and 1:46 min (range; 0:21–3: 20 min), respectively. Mean storage space per slide for H and E and TOLB slide was 0.83 GB (range: 0.12–1.73 GB) and 0.71 GB (range: 0.11–1.66 GB), respectively. Considering major discrepancies, the overall diagnostic concordance for OM and WSI, when compared with the reference standard, was 95.42% and 95.83%, respectively. There was almost perfect intra as well as inter-observer agreement (k ≥ 0.8) among 4 pathologists between WSI and OM for FS diagnosis. Mean turnaround time (TAT) of 14:58 min was observed using WSI for FS diagnosis, which was within the College of American Pathologists recommended range for FS reporting. The image quality was average to best quality in most of the cases. CONCLUSION: WSI was noninferior to OM for FS diagnosis across various specimen types. This portable WSI system can be safely adopted for routine FS diagnosis and provides an economically viable alternative to high-end scanners.
format Online
Article
Text
id pubmed-8529342
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-85293422021-11-09 Validation of a Portable Whole-Slide Imaging System for Frozen Section Diagnosis Kaushal, Rajiv Kumar Rajaganesan, Sathyanarayanan Rao, Vidya Sali, Akash More, Balaji Desai, Sangeeta B. J Pathol Inform Original Article BACKGROUND: Frozen section (FS) diagnosis is one of the promising applications of digital pathology (DP). However, the implementation of an appropriate and economically viable DP solution for FS in routine practice is challenging. The objective of this study was to establish the non-inferiority of whole-slide imaging (WSI) versus optical microscopy (OM) for FS diagnosis using a low cost and portable DP system. MATERIALS AND METHODS: A validation study to investigate the technical performance and diagnostic accuracy of WSI versus OM for FS diagnosis was performed using 60 FS cases[120 slides i.e, 60 hematoxylin and eosin (H & E) and 60 toluidine blue (TOLB)]. The diagnostic concordance, inter- and intra-observer agreement for FS diagnosis by WSI versus OM were recorded. RESULTS: The first time successful scanning rate was 89.1% (107/120). Mean scanning time per slide for H and E and TOLB slide was 1:47 min (range; 0:22–3: 21 min) and 1:46 min (range; 0:21–3: 20 min), respectively. Mean storage space per slide for H and E and TOLB slide was 0.83 GB (range: 0.12–1.73 GB) and 0.71 GB (range: 0.11–1.66 GB), respectively. Considering major discrepancies, the overall diagnostic concordance for OM and WSI, when compared with the reference standard, was 95.42% and 95.83%, respectively. There was almost perfect intra as well as inter-observer agreement (k ≥ 0.8) among 4 pathologists between WSI and OM for FS diagnosis. Mean turnaround time (TAT) of 14:58 min was observed using WSI for FS diagnosis, which was within the College of American Pathologists recommended range for FS reporting. The image quality was average to best quality in most of the cases. CONCLUSION: WSI was noninferior to OM for FS diagnosis across various specimen types. This portable WSI system can be safely adopted for routine FS diagnosis and provides an economically viable alternative to high-end scanners. Wolters Kluwer - Medknow 2021-09-16 /pmc/articles/PMC8529342/ /pubmed/34760330 http://dx.doi.org/10.4103/jpi.jpi_95_20 Text en Copyright: © 2021 Journal of Pathology Informatics https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Kaushal, Rajiv Kumar
Rajaganesan, Sathyanarayanan
Rao, Vidya
Sali, Akash
More, Balaji
Desai, Sangeeta B.
Validation of a Portable Whole-Slide Imaging System for Frozen Section Diagnosis
title Validation of a Portable Whole-Slide Imaging System for Frozen Section Diagnosis
title_full Validation of a Portable Whole-Slide Imaging System for Frozen Section Diagnosis
title_fullStr Validation of a Portable Whole-Slide Imaging System for Frozen Section Diagnosis
title_full_unstemmed Validation of a Portable Whole-Slide Imaging System for Frozen Section Diagnosis
title_short Validation of a Portable Whole-Slide Imaging System for Frozen Section Diagnosis
title_sort validation of a portable whole-slide imaging system for frozen section diagnosis
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8529342/
https://www.ncbi.nlm.nih.gov/pubmed/34760330
http://dx.doi.org/10.4103/jpi.jpi_95_20
work_keys_str_mv AT kaushalrajivkumar validationofaportablewholeslideimagingsystemforfrozensectiondiagnosis
AT rajaganesansathyanarayanan validationofaportablewholeslideimagingsystemforfrozensectiondiagnosis
AT raovidya validationofaportablewholeslideimagingsystemforfrozensectiondiagnosis
AT saliakash validationofaportablewholeslideimagingsystemforfrozensectiondiagnosis
AT morebalaji validationofaportablewholeslideimagingsystemforfrozensectiondiagnosis
AT desaisangeetab validationofaportablewholeslideimagingsystemforfrozensectiondiagnosis