Cargando…

Novel Ion Trap Scan Modes to Develop Criteria for On-Site Detection of Sulfonamide Antibiotics

[Image: see text] Advances in ambient ionization techniques have facilitated the direct analysis of complex mixtures without sample preparation. Significant attention has been given to innovating ionization methods so that multiple options are now available, allowing for ready selection of the best...

Descripción completa

Detalles Bibliográficos
Autores principales: Szalwinski, Lucas J., Hu, Yanyang, Morato, Nicolás M., Cooks, R. Graham, Salentijn, Gert IJ.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2021
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8529578/
https://www.ncbi.nlm.nih.gov/pubmed/34617742
http://dx.doi.org/10.1021/acs.analchem.1c02790
Descripción
Sumario:[Image: see text] Advances in ambient ionization techniques have facilitated the direct analysis of complex mixtures without sample preparation. Significant attention has been given to innovating ionization methods so that multiple options are now available, allowing for ready selection of the best methods for particular analyte classes. These ambient techniques are commonly implemented on benchtop systems, but their potential application with miniature mass spectrometers for in situ measurements is even more powerful. These applications require that attention be paid to tailoring the mass spectrometric methodology for the on-site operation. In this study, combinations of scan modes are employed to efficiently determine what tandem mass spectrometry (MS/MS) operations are most useful for detecting sulfonamides using a miniature ion trap after ionization. First, mixtures of representative sulfonamide antibiotics were interrogated using a 2D MS/MS scan on a benchtop ion trap in order to determine which class-specific fragments (ionic or neutral) are shared between the sulfonamides and thus have diagnostic value. Then, three less-used combination scans were recorded: (i) a simultaneous precursor ion scan was used to detect both analytes and an internal standard in a single ion injection event to optimize quantitative performance; (ii) a simultaneous precursor/neutral loss scan was used to improve detection limits; and finally, (iii) the simultaneous precursor/neutral loss scan was implemented in a miniature mass spectrometer and representative sulfonamides were detected at concentrations as low as 100 ng/mL by nano-electrospray and 0.5 ng absolute by paper spray ionization, although improvements in the stability of the home-built instrumentation are needed to further optimize performance.