Cargando…
Sensory Percepts Elicited by Chronic Macro-Sieve Electrode Stimulation of the Rat Sciatic Nerve
Objective: Intuitive control of conventional prostheses is hampered by their inability to provide the real-time tactile and proprioceptive feedback of natural sensory pathways. The macro-sieve electrode (MSE) is a candidate interface to amputees’ truncated peripheral nerves for introducing sensory f...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8530229/ https://www.ncbi.nlm.nih.gov/pubmed/34690689 http://dx.doi.org/10.3389/fnins.2021.758427 |
_version_ | 1784586630484459520 |
---|---|
author | Chandra, Nikhil S. McCarron, Weston M. Yan, Ying Ruiz, Luis C. Sallinger, Eric G. Birenbaum, Nathan K. Burton, Harold Green, Leonard Moran, Daniel W. Ray, Wilson Z. MacEwan, Matthew R. |
author_facet | Chandra, Nikhil S. McCarron, Weston M. Yan, Ying Ruiz, Luis C. Sallinger, Eric G. Birenbaum, Nathan K. Burton, Harold Green, Leonard Moran, Daniel W. Ray, Wilson Z. MacEwan, Matthew R. |
author_sort | Chandra, Nikhil S. |
collection | PubMed |
description | Objective: Intuitive control of conventional prostheses is hampered by their inability to provide the real-time tactile and proprioceptive feedback of natural sensory pathways. The macro-sieve electrode (MSE) is a candidate interface to amputees’ truncated peripheral nerves for introducing sensory feedback from external sensors to facilitate prosthetic control. Its unique geometry enables selective control of the complete nerve cross-section by current steering. Unlike previously studied interfaces that target intact nerve, the MSE’s implantation requires transection and subsequent regeneration of the target nerve. Therefore, a key determinant of the MSE’s suitability for this task is whether it can elicit sensory percepts at low current levels in the face of altered morphology and caliber distribution inherent to axon regeneration. The present in vivo study describes a combined rat sciatic nerve and behavioral model developed to answer this question. Approach: Rats learned a go/no-go detection task using auditory stimuli and then underwent surgery to implant the MSE in the sciatic nerve. After healing, they were trained with monopolar electrical stimuli with one multi-channel and eight single-channel stimulus configurations. Psychometric curves derived by the method of constant stimuli (MCS) were used to calculate 50% detection thresholds and associated psychometric slopes. Thresholds and slopes were calculated at two time points 3 weeks apart. Main Results: For the multi-channel stimulus configuration, the average current required for stimulus detection was 19.37 μA (3.87 nC) per channel. Single-channel thresholds for leads located near the nerve’s center were, on average, half those of leads located near the periphery (54.92 μA vs. 110.71 μA, or 10.98 nC vs. 22.14 nC). Longitudinally, 3 of 5 leads’ thresholds decreased or remained stable over the 3-week span. The remaining two leads’ thresholds increased by 70–74%, possibly due to scarring or device failure. Significance: This work represents an important first step in establishing the MSE’s viability as a sensory feedback interface. It further lays the groundwork for future experiments that will extend this model to the study of other devices, stimulus parameters, and task paradigms. |
format | Online Article Text |
id | pubmed-8530229 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-85302292021-10-22 Sensory Percepts Elicited by Chronic Macro-Sieve Electrode Stimulation of the Rat Sciatic Nerve Chandra, Nikhil S. McCarron, Weston M. Yan, Ying Ruiz, Luis C. Sallinger, Eric G. Birenbaum, Nathan K. Burton, Harold Green, Leonard Moran, Daniel W. Ray, Wilson Z. MacEwan, Matthew R. Front Neurosci Neuroscience Objective: Intuitive control of conventional prostheses is hampered by their inability to provide the real-time tactile and proprioceptive feedback of natural sensory pathways. The macro-sieve electrode (MSE) is a candidate interface to amputees’ truncated peripheral nerves for introducing sensory feedback from external sensors to facilitate prosthetic control. Its unique geometry enables selective control of the complete nerve cross-section by current steering. Unlike previously studied interfaces that target intact nerve, the MSE’s implantation requires transection and subsequent regeneration of the target nerve. Therefore, a key determinant of the MSE’s suitability for this task is whether it can elicit sensory percepts at low current levels in the face of altered morphology and caliber distribution inherent to axon regeneration. The present in vivo study describes a combined rat sciatic nerve and behavioral model developed to answer this question. Approach: Rats learned a go/no-go detection task using auditory stimuli and then underwent surgery to implant the MSE in the sciatic nerve. After healing, they were trained with monopolar electrical stimuli with one multi-channel and eight single-channel stimulus configurations. Psychometric curves derived by the method of constant stimuli (MCS) were used to calculate 50% detection thresholds and associated psychometric slopes. Thresholds and slopes were calculated at two time points 3 weeks apart. Main Results: For the multi-channel stimulus configuration, the average current required for stimulus detection was 19.37 μA (3.87 nC) per channel. Single-channel thresholds for leads located near the nerve’s center were, on average, half those of leads located near the periphery (54.92 μA vs. 110.71 μA, or 10.98 nC vs. 22.14 nC). Longitudinally, 3 of 5 leads’ thresholds decreased or remained stable over the 3-week span. The remaining two leads’ thresholds increased by 70–74%, possibly due to scarring or device failure. Significance: This work represents an important first step in establishing the MSE’s viability as a sensory feedback interface. It further lays the groundwork for future experiments that will extend this model to the study of other devices, stimulus parameters, and task paradigms. Frontiers Media S.A. 2021-10-07 /pmc/articles/PMC8530229/ /pubmed/34690689 http://dx.doi.org/10.3389/fnins.2021.758427 Text en Copyright © 2021 Chandra, McCarron, Yan, Ruiz, Sallinger, Birenbaum, Burton, Green, Moran, Ray and MacEwan. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Neuroscience Chandra, Nikhil S. McCarron, Weston M. Yan, Ying Ruiz, Luis C. Sallinger, Eric G. Birenbaum, Nathan K. Burton, Harold Green, Leonard Moran, Daniel W. Ray, Wilson Z. MacEwan, Matthew R. Sensory Percepts Elicited by Chronic Macro-Sieve Electrode Stimulation of the Rat Sciatic Nerve |
title | Sensory Percepts Elicited by Chronic Macro-Sieve Electrode Stimulation of the Rat Sciatic Nerve |
title_full | Sensory Percepts Elicited by Chronic Macro-Sieve Electrode Stimulation of the Rat Sciatic Nerve |
title_fullStr | Sensory Percepts Elicited by Chronic Macro-Sieve Electrode Stimulation of the Rat Sciatic Nerve |
title_full_unstemmed | Sensory Percepts Elicited by Chronic Macro-Sieve Electrode Stimulation of the Rat Sciatic Nerve |
title_short | Sensory Percepts Elicited by Chronic Macro-Sieve Electrode Stimulation of the Rat Sciatic Nerve |
title_sort | sensory percepts elicited by chronic macro-sieve electrode stimulation of the rat sciatic nerve |
topic | Neuroscience |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8530229/ https://www.ncbi.nlm.nih.gov/pubmed/34690689 http://dx.doi.org/10.3389/fnins.2021.758427 |
work_keys_str_mv | AT chandranikhils sensoryperceptselicitedbychronicmacrosieveelectrodestimulationoftheratsciaticnerve AT mccarronwestonm sensoryperceptselicitedbychronicmacrosieveelectrodestimulationoftheratsciaticnerve AT yanying sensoryperceptselicitedbychronicmacrosieveelectrodestimulationoftheratsciaticnerve AT ruizluisc sensoryperceptselicitedbychronicmacrosieveelectrodestimulationoftheratsciaticnerve AT sallingerericg sensoryperceptselicitedbychronicmacrosieveelectrodestimulationoftheratsciaticnerve AT birenbaumnathank sensoryperceptselicitedbychronicmacrosieveelectrodestimulationoftheratsciaticnerve AT burtonharold sensoryperceptselicitedbychronicmacrosieveelectrodestimulationoftheratsciaticnerve AT greenleonard sensoryperceptselicitedbychronicmacrosieveelectrodestimulationoftheratsciaticnerve AT morandanielw sensoryperceptselicitedbychronicmacrosieveelectrodestimulationoftheratsciaticnerve AT raywilsonz sensoryperceptselicitedbychronicmacrosieveelectrodestimulationoftheratsciaticnerve AT macewanmatthewr sensoryperceptselicitedbychronicmacrosieveelectrodestimulationoftheratsciaticnerve |