Accuracy of BIS monitoring using a novel interface device connecting conventional needle-electrodes and BIS sensors during frontal neurosurgical procedures
BACKGROUND: Bispectral index (BIS) monitoring is a widely used non-invasive method to monitor the depth of anesthesia. However, in the event of surgeries requiring a frontal approach, placement of the electrode may be impossible at the designated area to achieve a proper BIS measurement. METHODS: We...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8530286/ https://www.ncbi.nlm.nih.gov/pubmed/34673803 http://dx.doi.org/10.1371/journal.pone.0258647 |
_version_ | 1784586638419034112 |
---|---|
author | Harada, Hideki Muta, Seiya Kakuma, Tatsuyuki Ukeda, Misa Ota, So Hirata, Maiko Fujioka, Hiroshi Nakashima, Osamu Dietel, Barbara Tauchi, Miyuki |
author_facet | Harada, Hideki Muta, Seiya Kakuma, Tatsuyuki Ukeda, Misa Ota, So Hirata, Maiko Fujioka, Hiroshi Nakashima, Osamu Dietel, Barbara Tauchi, Miyuki |
author_sort | Harada, Hideki |
collection | PubMed |
description | BACKGROUND: Bispectral index (BIS) monitoring is a widely used non-invasive method to monitor the depth of anesthesia. However, in the event of surgeries requiring a frontal approach, placement of the electrode may be impossible at the designated area to achieve a proper BIS measurement. METHODS: We developed an investigational interface device to connect needle-electrodes to BIS sensors. The safety and clinical performance were investigated in patients who underwent surgery. Direct BIS values from a disposable BIS electrode and indirect values via the interface device were simultaneously recorded from the same areas of electrode placement in a single patient. The agreement between the direct and indirect BIS values was statistically analyzed. RESULTS: The interface device with a silver electrode demonstrated sufficient electric conduction to transmit electroencephalogram signals. The overall BIS curves were similar to those of direct BIS monitoring. Direct and indirect BIS values from 18 patients were statistically analyzed using a linear mixed model and a significant concordance was confirmed (indirect BIS = 7.0405 + 0.8286 * direct BIS, p<0.0001). Most observed data (2582/2787 data points, 92.64%) had BIS unit differences of 10 or less. CONCLUSIONS: The interface device provides an opportunity for intraoperative BIS monitoring of patients, whose clinical situation does not permit the placement of conventional adhesive sensors at the standard location. |
format | Online Article Text |
id | pubmed-8530286 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-85302862021-10-22 Accuracy of BIS monitoring using a novel interface device connecting conventional needle-electrodes and BIS sensors during frontal neurosurgical procedures Harada, Hideki Muta, Seiya Kakuma, Tatsuyuki Ukeda, Misa Ota, So Hirata, Maiko Fujioka, Hiroshi Nakashima, Osamu Dietel, Barbara Tauchi, Miyuki PLoS One Research Article BACKGROUND: Bispectral index (BIS) monitoring is a widely used non-invasive method to monitor the depth of anesthesia. However, in the event of surgeries requiring a frontal approach, placement of the electrode may be impossible at the designated area to achieve a proper BIS measurement. METHODS: We developed an investigational interface device to connect needle-electrodes to BIS sensors. The safety and clinical performance were investigated in patients who underwent surgery. Direct BIS values from a disposable BIS electrode and indirect values via the interface device were simultaneously recorded from the same areas of electrode placement in a single patient. The agreement between the direct and indirect BIS values was statistically analyzed. RESULTS: The interface device with a silver electrode demonstrated sufficient electric conduction to transmit electroencephalogram signals. The overall BIS curves were similar to those of direct BIS monitoring. Direct and indirect BIS values from 18 patients were statistically analyzed using a linear mixed model and a significant concordance was confirmed (indirect BIS = 7.0405 + 0.8286 * direct BIS, p<0.0001). Most observed data (2582/2787 data points, 92.64%) had BIS unit differences of 10 or less. CONCLUSIONS: The interface device provides an opportunity for intraoperative BIS monitoring of patients, whose clinical situation does not permit the placement of conventional adhesive sensors at the standard location. Public Library of Science 2021-10-21 /pmc/articles/PMC8530286/ /pubmed/34673803 http://dx.doi.org/10.1371/journal.pone.0258647 Text en © 2021 Harada et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Harada, Hideki Muta, Seiya Kakuma, Tatsuyuki Ukeda, Misa Ota, So Hirata, Maiko Fujioka, Hiroshi Nakashima, Osamu Dietel, Barbara Tauchi, Miyuki Accuracy of BIS monitoring using a novel interface device connecting conventional needle-electrodes and BIS sensors during frontal neurosurgical procedures |
title | Accuracy of BIS monitoring using a novel interface device connecting conventional needle-electrodes and BIS sensors during frontal neurosurgical procedures |
title_full | Accuracy of BIS monitoring using a novel interface device connecting conventional needle-electrodes and BIS sensors during frontal neurosurgical procedures |
title_fullStr | Accuracy of BIS monitoring using a novel interface device connecting conventional needle-electrodes and BIS sensors during frontal neurosurgical procedures |
title_full_unstemmed | Accuracy of BIS monitoring using a novel interface device connecting conventional needle-electrodes and BIS sensors during frontal neurosurgical procedures |
title_short | Accuracy of BIS monitoring using a novel interface device connecting conventional needle-electrodes and BIS sensors during frontal neurosurgical procedures |
title_sort | accuracy of bis monitoring using a novel interface device connecting conventional needle-electrodes and bis sensors during frontal neurosurgical procedures |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8530286/ https://www.ncbi.nlm.nih.gov/pubmed/34673803 http://dx.doi.org/10.1371/journal.pone.0258647 |
work_keys_str_mv | AT haradahideki accuracyofbismonitoringusinganovelinterfacedeviceconnectingconventionalneedleelectrodesandbissensorsduringfrontalneurosurgicalprocedures AT mutaseiya accuracyofbismonitoringusinganovelinterfacedeviceconnectingconventionalneedleelectrodesandbissensorsduringfrontalneurosurgicalprocedures AT kakumatatsuyuki accuracyofbismonitoringusinganovelinterfacedeviceconnectingconventionalneedleelectrodesandbissensorsduringfrontalneurosurgicalprocedures AT ukedamisa accuracyofbismonitoringusinganovelinterfacedeviceconnectingconventionalneedleelectrodesandbissensorsduringfrontalneurosurgicalprocedures AT otaso accuracyofbismonitoringusinganovelinterfacedeviceconnectingconventionalneedleelectrodesandbissensorsduringfrontalneurosurgicalprocedures AT hiratamaiko accuracyofbismonitoringusinganovelinterfacedeviceconnectingconventionalneedleelectrodesandbissensorsduringfrontalneurosurgicalprocedures AT fujiokahiroshi accuracyofbismonitoringusinganovelinterfacedeviceconnectingconventionalneedleelectrodesandbissensorsduringfrontalneurosurgicalprocedures AT nakashimaosamu accuracyofbismonitoringusinganovelinterfacedeviceconnectingconventionalneedleelectrodesandbissensorsduringfrontalneurosurgicalprocedures AT dietelbarbara accuracyofbismonitoringusinganovelinterfacedeviceconnectingconventionalneedleelectrodesandbissensorsduringfrontalneurosurgicalprocedures AT tauchimiyuki accuracyofbismonitoringusinganovelinterfacedeviceconnectingconventionalneedleelectrodesandbissensorsduringfrontalneurosurgicalprocedures |