Cargando…
The technology of artificial pneumoperitoneum CT and its application in diagnosis of abdominal adhesion
To retrospectively analyze the use of artificial pneumoperitoneum in CT scans, to explore its operation methods and technical points, and to lay the foundation for the widespread application of artificial pneumoperitoneum in CT. A total of 331 patients who underwent artificial pneumoperitoneum with...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8531012/ https://www.ncbi.nlm.nih.gov/pubmed/34675300 http://dx.doi.org/10.1038/s41598-021-00408-1 |
_version_ | 1784586763620057088 |
---|---|
author | Wang, Gui-sheng Zhang, Zhi-yi Qi, Xue-ting Liu, Jin Liu, Ting Zhao, Jing-wei Chen, Xiao-xia Chen, Yi |
author_facet | Wang, Gui-sheng Zhang, Zhi-yi Qi, Xue-ting Liu, Jin Liu, Ting Zhao, Jing-wei Chen, Xiao-xia Chen, Yi |
author_sort | Wang, Gui-sheng |
collection | PubMed |
description | To retrospectively analyze the use of artificial pneumoperitoneum in CT scans, to explore its operation methods and technical points, and to lay the foundation for the widespread application of artificial pneumoperitoneum in CT. A total of 331 patients who underwent artificial pneumoperitoneum with CT angiography from January 1, 2013, to November 1, 2019, were recruited. All patients underwent standardized artificial pneumoperitoneum in the horizontal, left and right lateral, and prone positions during CT thin-layer scans of the abdomen and 3D reconstruction. Taking the surgical results as the gold standard, and using kappa test to verify the consistency of surgical results and imaging results. In all 331 patients, 43 patients had a normal peritoneal space, and 288 patients had an abnormal peritoneal space. And only 22 patients developed complications of subcutaneous emphysema, accounting for 6.6% of all 331 patients. In terms of the postoperative results, 28 were normal, and 303 were abnormal. The sensitivity, specificity and accuracy of CT diagnosis of abdominal adhesions using artificial pneumoperitoneum were 100%, 95.04%, and 95.46%, respectively. According to the Kappa consistency test, the imaging diagnosis from the CT scan with artificial pneumoperitoneum had a high consistency with the surgical results (kappa = 0.796, P < 0.05). The technique of artificial pneumoperitoneum CT is safe, reliable, highly practical, and proficient for obtaining good imaging results. It provides a good imaging basis for the diagnosis of intra-abdominal diseases, especially intra-abdominal adhesions. |
format | Online Article Text |
id | pubmed-8531012 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-85310122021-10-22 The technology of artificial pneumoperitoneum CT and its application in diagnosis of abdominal adhesion Wang, Gui-sheng Zhang, Zhi-yi Qi, Xue-ting Liu, Jin Liu, Ting Zhao, Jing-wei Chen, Xiao-xia Chen, Yi Sci Rep Article To retrospectively analyze the use of artificial pneumoperitoneum in CT scans, to explore its operation methods and technical points, and to lay the foundation for the widespread application of artificial pneumoperitoneum in CT. A total of 331 patients who underwent artificial pneumoperitoneum with CT angiography from January 1, 2013, to November 1, 2019, were recruited. All patients underwent standardized artificial pneumoperitoneum in the horizontal, left and right lateral, and prone positions during CT thin-layer scans of the abdomen and 3D reconstruction. Taking the surgical results as the gold standard, and using kappa test to verify the consistency of surgical results and imaging results. In all 331 patients, 43 patients had a normal peritoneal space, and 288 patients had an abnormal peritoneal space. And only 22 patients developed complications of subcutaneous emphysema, accounting for 6.6% of all 331 patients. In terms of the postoperative results, 28 were normal, and 303 were abnormal. The sensitivity, specificity and accuracy of CT diagnosis of abdominal adhesions using artificial pneumoperitoneum were 100%, 95.04%, and 95.46%, respectively. According to the Kappa consistency test, the imaging diagnosis from the CT scan with artificial pneumoperitoneum had a high consistency with the surgical results (kappa = 0.796, P < 0.05). The technique of artificial pneumoperitoneum CT is safe, reliable, highly practical, and proficient for obtaining good imaging results. It provides a good imaging basis for the diagnosis of intra-abdominal diseases, especially intra-abdominal adhesions. Nature Publishing Group UK 2021-10-21 /pmc/articles/PMC8531012/ /pubmed/34675300 http://dx.doi.org/10.1038/s41598-021-00408-1 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Wang, Gui-sheng Zhang, Zhi-yi Qi, Xue-ting Liu, Jin Liu, Ting Zhao, Jing-wei Chen, Xiao-xia Chen, Yi The technology of artificial pneumoperitoneum CT and its application in diagnosis of abdominal adhesion |
title | The technology of artificial pneumoperitoneum CT and its application in diagnosis of abdominal adhesion |
title_full | The technology of artificial pneumoperitoneum CT and its application in diagnosis of abdominal adhesion |
title_fullStr | The technology of artificial pneumoperitoneum CT and its application in diagnosis of abdominal adhesion |
title_full_unstemmed | The technology of artificial pneumoperitoneum CT and its application in diagnosis of abdominal adhesion |
title_short | The technology of artificial pneumoperitoneum CT and its application in diagnosis of abdominal adhesion |
title_sort | technology of artificial pneumoperitoneum ct and its application in diagnosis of abdominal adhesion |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8531012/ https://www.ncbi.nlm.nih.gov/pubmed/34675300 http://dx.doi.org/10.1038/s41598-021-00408-1 |
work_keys_str_mv | AT wangguisheng thetechnologyofartificialpneumoperitoneumctanditsapplicationindiagnosisofabdominaladhesion AT zhangzhiyi thetechnologyofartificialpneumoperitoneumctanditsapplicationindiagnosisofabdominaladhesion AT qixueting thetechnologyofartificialpneumoperitoneumctanditsapplicationindiagnosisofabdominaladhesion AT liujin thetechnologyofartificialpneumoperitoneumctanditsapplicationindiagnosisofabdominaladhesion AT liuting thetechnologyofartificialpneumoperitoneumctanditsapplicationindiagnosisofabdominaladhesion AT zhaojingwei thetechnologyofartificialpneumoperitoneumctanditsapplicationindiagnosisofabdominaladhesion AT chenxiaoxia thetechnologyofartificialpneumoperitoneumctanditsapplicationindiagnosisofabdominaladhesion AT chenyi thetechnologyofartificialpneumoperitoneumctanditsapplicationindiagnosisofabdominaladhesion AT wangguisheng technologyofartificialpneumoperitoneumctanditsapplicationindiagnosisofabdominaladhesion AT zhangzhiyi technologyofartificialpneumoperitoneumctanditsapplicationindiagnosisofabdominaladhesion AT qixueting technologyofartificialpneumoperitoneumctanditsapplicationindiagnosisofabdominaladhesion AT liujin technologyofartificialpneumoperitoneumctanditsapplicationindiagnosisofabdominaladhesion AT liuting technologyofartificialpneumoperitoneumctanditsapplicationindiagnosisofabdominaladhesion AT zhaojingwei technologyofartificialpneumoperitoneumctanditsapplicationindiagnosisofabdominaladhesion AT chenxiaoxia technologyofartificialpneumoperitoneumctanditsapplicationindiagnosisofabdominaladhesion AT chenyi technologyofartificialpneumoperitoneumctanditsapplicationindiagnosisofabdominaladhesion |