Cargando…

Value of D-Dimer as a Diagnostic Marker of Infection Associated with Orthopedic Implants

BACKGROUND: Recently, the D-dimer biomarker has gained the researchers' attention for predicting infections. We aimed to determine the relationship between this marker and other inflammatory markers involved in orthopedic implant-associated infections. MATERIALS AND METHODS: In this study, all...

Descripción completa

Detalles Bibliográficos
Autores principales: Ebrahimpour, Adel, Okhovatpour, Mohammad Ali, Tabrizi, Ali, Bakhshmandi, Mahsa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8531734/
https://www.ncbi.nlm.nih.gov/pubmed/34760810
http://dx.doi.org/10.4103/abr.abr_277_20
_version_ 1784586926352760832
author Ebrahimpour, Adel
Okhovatpour, Mohammad Ali
Tabrizi, Ali
Bakhshmandi, Mahsa
author_facet Ebrahimpour, Adel
Okhovatpour, Mohammad Ali
Tabrizi, Ali
Bakhshmandi, Mahsa
author_sort Ebrahimpour, Adel
collection PubMed
description BACKGROUND: Recently, the D-dimer biomarker has gained the researchers' attention for predicting infections. We aimed to determine the relationship between this marker and other inflammatory markers involved in orthopedic implant-associated infections. MATERIALS AND METHODS: In this study, all patients diagnosed with an orthopedic implant-associated infection were investigated in 3 years. The serum level of D-dimer, erythrocyte sedimentation rate (ESR), and C-reactive protein (CRP) was measured. Infection was diagnosed based on the clinical and culture results of biopsy samples. RESULTS: The cultured microorganisms, detected in 26 patients with infections, included Staphylococcus aureus (n = 13, 50%), Staphylococcus epidermidis (n = 2, 7.7%), Klebsiella aerogenes (n = 8, 30.8%), and Pseudomonas aeruginosa (n = 3, 11. 5%). Based on laboratory findings, there was a significant difference in the CRP level and ESR (P = 0.001). Although the level of D-dimer was higher in infected patients, compared to the controls (992.6 ± 667.2 vs. 690.1 ± 250.2 ng/mL), the difference was not statistically significant. There was no significant correlation between the elevated D-dimer level and CRP level, whereas ESR had a positive correlation with the elevated D-dimer level (r = 0.6, P = 0.03). The sensitivity, specificity, and positive predictive value (PPV) of D-dimer in the prediction of infection were 65%, 57%, and 45%, respectively. Furthermore, the sensitivity, specificity, and PPV of CRP were 100%, 92.3%, and 95%, respectively, whereas the corresponding values for ESR were 85%, 69.2%, and 62%, respectively. CONCLUSION: Measurement of the serum D-dimer level is not efficient for the diagnosis of orthopedic implant-associated infections due to its low predictive value. Furthermore, there was no significant correlation between the serum D-dimer level and CRP.
format Online
Article
Text
id pubmed-8531734
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-85317342021-11-09 Value of D-Dimer as a Diagnostic Marker of Infection Associated with Orthopedic Implants Ebrahimpour, Adel Okhovatpour, Mohammad Ali Tabrizi, Ali Bakhshmandi, Mahsa Adv Biomed Res Original Article BACKGROUND: Recently, the D-dimer biomarker has gained the researchers' attention for predicting infections. We aimed to determine the relationship between this marker and other inflammatory markers involved in orthopedic implant-associated infections. MATERIALS AND METHODS: In this study, all patients diagnosed with an orthopedic implant-associated infection were investigated in 3 years. The serum level of D-dimer, erythrocyte sedimentation rate (ESR), and C-reactive protein (CRP) was measured. Infection was diagnosed based on the clinical and culture results of biopsy samples. RESULTS: The cultured microorganisms, detected in 26 patients with infections, included Staphylococcus aureus (n = 13, 50%), Staphylococcus epidermidis (n = 2, 7.7%), Klebsiella aerogenes (n = 8, 30.8%), and Pseudomonas aeruginosa (n = 3, 11. 5%). Based on laboratory findings, there was a significant difference in the CRP level and ESR (P = 0.001). Although the level of D-dimer was higher in infected patients, compared to the controls (992.6 ± 667.2 vs. 690.1 ± 250.2 ng/mL), the difference was not statistically significant. There was no significant correlation between the elevated D-dimer level and CRP level, whereas ESR had a positive correlation with the elevated D-dimer level (r = 0.6, P = 0.03). The sensitivity, specificity, and positive predictive value (PPV) of D-dimer in the prediction of infection were 65%, 57%, and 45%, respectively. Furthermore, the sensitivity, specificity, and PPV of CRP were 100%, 92.3%, and 95%, respectively, whereas the corresponding values for ESR were 85%, 69.2%, and 62%, respectively. CONCLUSION: Measurement of the serum D-dimer level is not efficient for the diagnosis of orthopedic implant-associated infections due to its low predictive value. Furthermore, there was no significant correlation between the serum D-dimer level and CRP. Wolters Kluwer - Medknow 2021-09-29 /pmc/articles/PMC8531734/ /pubmed/34760810 http://dx.doi.org/10.4103/abr.abr_277_20 Text en Copyright: © 2021 Advanced Biomedical Research https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Ebrahimpour, Adel
Okhovatpour, Mohammad Ali
Tabrizi, Ali
Bakhshmandi, Mahsa
Value of D-Dimer as a Diagnostic Marker of Infection Associated with Orthopedic Implants
title Value of D-Dimer as a Diagnostic Marker of Infection Associated with Orthopedic Implants
title_full Value of D-Dimer as a Diagnostic Marker of Infection Associated with Orthopedic Implants
title_fullStr Value of D-Dimer as a Diagnostic Marker of Infection Associated with Orthopedic Implants
title_full_unstemmed Value of D-Dimer as a Diagnostic Marker of Infection Associated with Orthopedic Implants
title_short Value of D-Dimer as a Diagnostic Marker of Infection Associated with Orthopedic Implants
title_sort value of d-dimer as a diagnostic marker of infection associated with orthopedic implants
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8531734/
https://www.ncbi.nlm.nih.gov/pubmed/34760810
http://dx.doi.org/10.4103/abr.abr_277_20
work_keys_str_mv AT ebrahimpouradel valueofddimerasadiagnosticmarkerofinfectionassociatedwithorthopedicimplants
AT okhovatpourmohammadali valueofddimerasadiagnosticmarkerofinfectionassociatedwithorthopedicimplants
AT tabriziali valueofddimerasadiagnosticmarkerofinfectionassociatedwithorthopedicimplants
AT bakhshmandimahsa valueofddimerasadiagnosticmarkerofinfectionassociatedwithorthopedicimplants