Cargando…

The Prognostic Impact of Estimated Creatinine Clearance by Bioelectrical Impedance Analysis in Heart Failure: Comparison of Different eGFR Formulas

The estimation of glomerular filtration rate (eGFR) provides prognostic information in patients with heart failure (HF). Bioelectrical impedance analysis may calculate eGFR (Donadio formula). The aim of this study was to evaluate the impact of the Donadio formula in predicting all-cause mortality in...

Descripción completa

Detalles Bibliográficos
Autores principales: Scicchitano, Pietro, Iacoviello, Massimo, Passantino, Andrea, Guida, Piero, De Palo, Micaela, Piscopo, Assunta, Gesualdo, Michele, Caldarola, Pasquale, Massari, Francesco
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8533548/
https://www.ncbi.nlm.nih.gov/pubmed/34680423
http://dx.doi.org/10.3390/biomedicines9101307
_version_ 1784587340293865472
author Scicchitano, Pietro
Iacoviello, Massimo
Passantino, Andrea
Guida, Piero
De Palo, Micaela
Piscopo, Assunta
Gesualdo, Michele
Caldarola, Pasquale
Massari, Francesco
author_facet Scicchitano, Pietro
Iacoviello, Massimo
Passantino, Andrea
Guida, Piero
De Palo, Micaela
Piscopo, Assunta
Gesualdo, Michele
Caldarola, Pasquale
Massari, Francesco
author_sort Scicchitano, Pietro
collection PubMed
description The estimation of glomerular filtration rate (eGFR) provides prognostic information in patients with heart failure (HF). Bioelectrical impedance analysis may calculate eGFR (Donadio formula). The aim of this study was to evaluate the impact of the Donadio formula in predicting all-cause mortality in patients with HF as compared to Cockroft-Gault, MDRD-4 (Modification of Diet in renal Disease Study), and Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) formulas. Four-hundred thirty-six subjects with HF (52% men; mean age 75 ± 11 years; 42% acute HF) were enrolled. Ninety-two patients (21%) died during the follow-up (median 463 days, IQR 287–669). The area under the receiver operator characteristic curve for eGFR, as estimated by Cockroft-Gault formula (AUC = 0.75), was significantly higher than those derived from Donadio (AUC = 0.72), MDRD-4 (AUC = 0.68), and CKD-EPI (AUC = 0.71) formulas. At multivariate analysis, all eGFR formulas were independent predictors of death; 1 mL/min/1.73 m(2) increase in eGFR—as measured by Cockroft-Gault, Donadio, MDRD-4, and CKD-EPI formulas—provided a 2.6%, 1.5%, 1.2%, and 1.6% increase, respectively, in mortality rate. Conclusions. eGFR, as calculated with the Donadio formula, was an independent predictor of mortality in patients with HF as well as the measurements derived from MDRD4 and CKD-EPI formulas, but less accurate than Cockroft-Gault.
format Online
Article
Text
id pubmed-8533548
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-85335482021-10-23 The Prognostic Impact of Estimated Creatinine Clearance by Bioelectrical Impedance Analysis in Heart Failure: Comparison of Different eGFR Formulas Scicchitano, Pietro Iacoviello, Massimo Passantino, Andrea Guida, Piero De Palo, Micaela Piscopo, Assunta Gesualdo, Michele Caldarola, Pasquale Massari, Francesco Biomedicines Article The estimation of glomerular filtration rate (eGFR) provides prognostic information in patients with heart failure (HF). Bioelectrical impedance analysis may calculate eGFR (Donadio formula). The aim of this study was to evaluate the impact of the Donadio formula in predicting all-cause mortality in patients with HF as compared to Cockroft-Gault, MDRD-4 (Modification of Diet in renal Disease Study), and Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) formulas. Four-hundred thirty-six subjects with HF (52% men; mean age 75 ± 11 years; 42% acute HF) were enrolled. Ninety-two patients (21%) died during the follow-up (median 463 days, IQR 287–669). The area under the receiver operator characteristic curve for eGFR, as estimated by Cockroft-Gault formula (AUC = 0.75), was significantly higher than those derived from Donadio (AUC = 0.72), MDRD-4 (AUC = 0.68), and CKD-EPI (AUC = 0.71) formulas. At multivariate analysis, all eGFR formulas were independent predictors of death; 1 mL/min/1.73 m(2) increase in eGFR—as measured by Cockroft-Gault, Donadio, MDRD-4, and CKD-EPI formulas—provided a 2.6%, 1.5%, 1.2%, and 1.6% increase, respectively, in mortality rate. Conclusions. eGFR, as calculated with the Donadio formula, was an independent predictor of mortality in patients with HF as well as the measurements derived from MDRD4 and CKD-EPI formulas, but less accurate than Cockroft-Gault. MDPI 2021-09-24 /pmc/articles/PMC8533548/ /pubmed/34680423 http://dx.doi.org/10.3390/biomedicines9101307 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Scicchitano, Pietro
Iacoviello, Massimo
Passantino, Andrea
Guida, Piero
De Palo, Micaela
Piscopo, Assunta
Gesualdo, Michele
Caldarola, Pasquale
Massari, Francesco
The Prognostic Impact of Estimated Creatinine Clearance by Bioelectrical Impedance Analysis in Heart Failure: Comparison of Different eGFR Formulas
title The Prognostic Impact of Estimated Creatinine Clearance by Bioelectrical Impedance Analysis in Heart Failure: Comparison of Different eGFR Formulas
title_full The Prognostic Impact of Estimated Creatinine Clearance by Bioelectrical Impedance Analysis in Heart Failure: Comparison of Different eGFR Formulas
title_fullStr The Prognostic Impact of Estimated Creatinine Clearance by Bioelectrical Impedance Analysis in Heart Failure: Comparison of Different eGFR Formulas
title_full_unstemmed The Prognostic Impact of Estimated Creatinine Clearance by Bioelectrical Impedance Analysis in Heart Failure: Comparison of Different eGFR Formulas
title_short The Prognostic Impact of Estimated Creatinine Clearance by Bioelectrical Impedance Analysis in Heart Failure: Comparison of Different eGFR Formulas
title_sort prognostic impact of estimated creatinine clearance by bioelectrical impedance analysis in heart failure: comparison of different egfr formulas
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8533548/
https://www.ncbi.nlm.nih.gov/pubmed/34680423
http://dx.doi.org/10.3390/biomedicines9101307
work_keys_str_mv AT scicchitanopietro theprognosticimpactofestimatedcreatinineclearancebybioelectricalimpedanceanalysisinheartfailurecomparisonofdifferentegfrformulas
AT iacoviellomassimo theprognosticimpactofestimatedcreatinineclearancebybioelectricalimpedanceanalysisinheartfailurecomparisonofdifferentegfrformulas
AT passantinoandrea theprognosticimpactofestimatedcreatinineclearancebybioelectricalimpedanceanalysisinheartfailurecomparisonofdifferentegfrformulas
AT guidapiero theprognosticimpactofestimatedcreatinineclearancebybioelectricalimpedanceanalysisinheartfailurecomparisonofdifferentegfrformulas
AT depalomicaela theprognosticimpactofestimatedcreatinineclearancebybioelectricalimpedanceanalysisinheartfailurecomparisonofdifferentegfrformulas
AT piscopoassunta theprognosticimpactofestimatedcreatinineclearancebybioelectricalimpedanceanalysisinheartfailurecomparisonofdifferentegfrformulas
AT gesualdomichele theprognosticimpactofestimatedcreatinineclearancebybioelectricalimpedanceanalysisinheartfailurecomparisonofdifferentegfrformulas
AT caldarolapasquale theprognosticimpactofestimatedcreatinineclearancebybioelectricalimpedanceanalysisinheartfailurecomparisonofdifferentegfrformulas
AT massarifrancesco theprognosticimpactofestimatedcreatinineclearancebybioelectricalimpedanceanalysisinheartfailurecomparisonofdifferentegfrformulas
AT scicchitanopietro prognosticimpactofestimatedcreatinineclearancebybioelectricalimpedanceanalysisinheartfailurecomparisonofdifferentegfrformulas
AT iacoviellomassimo prognosticimpactofestimatedcreatinineclearancebybioelectricalimpedanceanalysisinheartfailurecomparisonofdifferentegfrformulas
AT passantinoandrea prognosticimpactofestimatedcreatinineclearancebybioelectricalimpedanceanalysisinheartfailurecomparisonofdifferentegfrformulas
AT guidapiero prognosticimpactofestimatedcreatinineclearancebybioelectricalimpedanceanalysisinheartfailurecomparisonofdifferentegfrformulas
AT depalomicaela prognosticimpactofestimatedcreatinineclearancebybioelectricalimpedanceanalysisinheartfailurecomparisonofdifferentegfrformulas
AT piscopoassunta prognosticimpactofestimatedcreatinineclearancebybioelectricalimpedanceanalysisinheartfailurecomparisonofdifferentegfrformulas
AT gesualdomichele prognosticimpactofestimatedcreatinineclearancebybioelectricalimpedanceanalysisinheartfailurecomparisonofdifferentegfrformulas
AT caldarolapasquale prognosticimpactofestimatedcreatinineclearancebybioelectricalimpedanceanalysisinheartfailurecomparisonofdifferentegfrformulas
AT massarifrancesco prognosticimpactofestimatedcreatinineclearancebybioelectricalimpedanceanalysisinheartfailurecomparisonofdifferentegfrformulas