Cargando…
Apoptosis Quantification in Tissue: Development of a Semi-Automatic Protocol and Assessment of Critical Steps of Image Processing
Apoptosis is associated with numerous phenotypical characteristics, and is thus studied with many tools. In this study, we compared two broadly used apoptotic assays: TUNEL and staining with an antibody targeting the activated form of an effector caspase. To compare them, we developed a protocol bas...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8533694/ https://www.ncbi.nlm.nih.gov/pubmed/34680157 http://dx.doi.org/10.3390/biom11101523 |
_version_ | 1784587375102394368 |
---|---|
author | de Noiron, Juliette Hoareau, Marion Colin, Jessie Guénal, Isabelle |
author_facet | de Noiron, Juliette Hoareau, Marion Colin, Jessie Guénal, Isabelle |
author_sort | de Noiron, Juliette |
collection | PubMed |
description | Apoptosis is associated with numerous phenotypical characteristics, and is thus studied with many tools. In this study, we compared two broadly used apoptotic assays: TUNEL and staining with an antibody targeting the activated form of an effector caspase. To compare them, we developed a protocol based on commonly used tools such as image filtering, z-projection, and thresholding. Even though it is commonly used in image-processing protocols, thresholding remains a recurring problem. Here, we analyzed the impact of processing parameters and readout choice on the accuracy of apoptotic signal quantification. Our results show that TUNEL is quite robust, even if image processing parameters may not always allow to detect subtle differences of the apoptotic rate. On the contrary, images from anti-cleaved caspase staining are more sensitive to handle and necessitate being processed more carefully. We then developed an open-source Fiji macro automatizing most steps of the image processing and quantification protocol. It is noteworthy that the field of application of this macro is wider than apoptosis and it can be used to treat and quantify other kind of images. |
format | Online Article Text |
id | pubmed-8533694 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-85336942021-10-23 Apoptosis Quantification in Tissue: Development of a Semi-Automatic Protocol and Assessment of Critical Steps of Image Processing de Noiron, Juliette Hoareau, Marion Colin, Jessie Guénal, Isabelle Biomolecules Article Apoptosis is associated with numerous phenotypical characteristics, and is thus studied with many tools. In this study, we compared two broadly used apoptotic assays: TUNEL and staining with an antibody targeting the activated form of an effector caspase. To compare them, we developed a protocol based on commonly used tools such as image filtering, z-projection, and thresholding. Even though it is commonly used in image-processing protocols, thresholding remains a recurring problem. Here, we analyzed the impact of processing parameters and readout choice on the accuracy of apoptotic signal quantification. Our results show that TUNEL is quite robust, even if image processing parameters may not always allow to detect subtle differences of the apoptotic rate. On the contrary, images from anti-cleaved caspase staining are more sensitive to handle and necessitate being processed more carefully. We then developed an open-source Fiji macro automatizing most steps of the image processing and quantification protocol. It is noteworthy that the field of application of this macro is wider than apoptosis and it can be used to treat and quantify other kind of images. MDPI 2021-10-15 /pmc/articles/PMC8533694/ /pubmed/34680157 http://dx.doi.org/10.3390/biom11101523 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article de Noiron, Juliette Hoareau, Marion Colin, Jessie Guénal, Isabelle Apoptosis Quantification in Tissue: Development of a Semi-Automatic Protocol and Assessment of Critical Steps of Image Processing |
title | Apoptosis Quantification in Tissue: Development of a Semi-Automatic Protocol and Assessment of Critical Steps of Image Processing |
title_full | Apoptosis Quantification in Tissue: Development of a Semi-Automatic Protocol and Assessment of Critical Steps of Image Processing |
title_fullStr | Apoptosis Quantification in Tissue: Development of a Semi-Automatic Protocol and Assessment of Critical Steps of Image Processing |
title_full_unstemmed | Apoptosis Quantification in Tissue: Development of a Semi-Automatic Protocol and Assessment of Critical Steps of Image Processing |
title_short | Apoptosis Quantification in Tissue: Development of a Semi-Automatic Protocol and Assessment of Critical Steps of Image Processing |
title_sort | apoptosis quantification in tissue: development of a semi-automatic protocol and assessment of critical steps of image processing |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8533694/ https://www.ncbi.nlm.nih.gov/pubmed/34680157 http://dx.doi.org/10.3390/biom11101523 |
work_keys_str_mv | AT denoironjuliette apoptosisquantificationintissuedevelopmentofasemiautomaticprotocolandassessmentofcriticalstepsofimageprocessing AT hoareaumarion apoptosisquantificationintissuedevelopmentofasemiautomaticprotocolandassessmentofcriticalstepsofimageprocessing AT colinjessie apoptosisquantificationintissuedevelopmentofasemiautomaticprotocolandassessmentofcriticalstepsofimageprocessing AT guenalisabelle apoptosisquantificationintissuedevelopmentofasemiautomaticprotocolandassessmentofcriticalstepsofimageprocessing |