Cargando…

Single-Breath-Hold MRI-SPACE Cholangiopancreatography with Compressed Sensing versus Conventional Respiratory-Triggered MRI-SPACE Cholangiopancreatography at 3Tesla: Comparison of Image Quality and Diagnostic Confidence

To compare two magnetic resonance cholangiopancreatography (MRCP) sequences at 3 Tesla (3T): the conventional 3D Respiratory-Triggered SPACE sequence (RT-MRCP) and a prototype 3D Compressed-Sensing Breath-Hold SPACE sequence (CS-BH-MRCP), in terms of qualitative and quantitative image quality and ra...

Descripción completa

Detalles Bibliográficos
Autores principales: Chevallier, Olivier, Escande, Hélène, Ambarki, Khalid, Weiland, Elisabeth, Kuehn, Bernd, Guillen, Kévin, Manfredi, Sylvain, Gehin, Sophie, Blanc, Julie, Loffroy, Romaric
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8534472/
https://www.ncbi.nlm.nih.gov/pubmed/34679584
http://dx.doi.org/10.3390/diagnostics11101886
_version_ 1784587561274966016
author Chevallier, Olivier
Escande, Hélène
Ambarki, Khalid
Weiland, Elisabeth
Kuehn, Bernd
Guillen, Kévin
Manfredi, Sylvain
Gehin, Sophie
Blanc, Julie
Loffroy, Romaric
author_facet Chevallier, Olivier
Escande, Hélène
Ambarki, Khalid
Weiland, Elisabeth
Kuehn, Bernd
Guillen, Kévin
Manfredi, Sylvain
Gehin, Sophie
Blanc, Julie
Loffroy, Romaric
author_sort Chevallier, Olivier
collection PubMed
description To compare two magnetic resonance cholangiopancreatography (MRCP) sequences at 3 Tesla (3T): the conventional 3D Respiratory-Triggered SPACE sequence (RT-MRCP) and a prototype 3D Compressed-Sensing Breath-Hold SPACE sequence (CS-BH-MRCP), in terms of qualitative and quantitative image quality and radiologist’s diagnostic confidence for detecting common bile duct (CBD) lithiasis, biliary anastomosis stenosis in liver-transplant recipients, and communication of pancreatic cyst with the main pancreatic duct (MPD). Sixty-eight patients with suspicion of choledocholithiasis or biliary anastomosis stenosis after liver transplant, or branch-duct intraductal papillary mucinous neoplasm of the pancreas (BD-IPMN), were included. The relative CBD to peri-biliary tissues (PBT) contrast ratio (CR) was assessed. Overall image quality, presence of artefacts, background noise suppression and the visualization of 12 separated segments of the pancreatic and bile ducts were evaluated by two observers working independently on a five-point scale. Diagnostic confidence was scored on a 1–3 scale. The CS-BH-MRCP presented significantly better CRs (p < 0.0001), image quality (p = 0.004), background noise suppression (p = 0.011), fewer artefacts (p = 0.004) and better visualization of pancreatic and bile ducts segments with the exception of the proximal CBD (p = 0.054), cystic duct confluence (p = 0.459), the four secondary intrahepatic bile ducts, and central part of the MPD (p = 0.885) for which no significant differences were found. Overall, diagnostic confidence was significantly better with the CS-BH-MRCP sequence for both readers (p = 0.038 and p = 0.038, respectively). This study shows that the CS-BH-MRCP sequence presents overall better image quality and bile and pancreatic ducts visualization compared to the conventional RT-MRCP sequence at 3T.
format Online
Article
Text
id pubmed-8534472
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-85344722021-10-23 Single-Breath-Hold MRI-SPACE Cholangiopancreatography with Compressed Sensing versus Conventional Respiratory-Triggered MRI-SPACE Cholangiopancreatography at 3Tesla: Comparison of Image Quality and Diagnostic Confidence Chevallier, Olivier Escande, Hélène Ambarki, Khalid Weiland, Elisabeth Kuehn, Bernd Guillen, Kévin Manfredi, Sylvain Gehin, Sophie Blanc, Julie Loffroy, Romaric Diagnostics (Basel) Article To compare two magnetic resonance cholangiopancreatography (MRCP) sequences at 3 Tesla (3T): the conventional 3D Respiratory-Triggered SPACE sequence (RT-MRCP) and a prototype 3D Compressed-Sensing Breath-Hold SPACE sequence (CS-BH-MRCP), in terms of qualitative and quantitative image quality and radiologist’s diagnostic confidence for detecting common bile duct (CBD) lithiasis, biliary anastomosis stenosis in liver-transplant recipients, and communication of pancreatic cyst with the main pancreatic duct (MPD). Sixty-eight patients with suspicion of choledocholithiasis or biliary anastomosis stenosis after liver transplant, or branch-duct intraductal papillary mucinous neoplasm of the pancreas (BD-IPMN), were included. The relative CBD to peri-biliary tissues (PBT) contrast ratio (CR) was assessed. Overall image quality, presence of artefacts, background noise suppression and the visualization of 12 separated segments of the pancreatic and bile ducts were evaluated by two observers working independently on a five-point scale. Diagnostic confidence was scored on a 1–3 scale. The CS-BH-MRCP presented significantly better CRs (p < 0.0001), image quality (p = 0.004), background noise suppression (p = 0.011), fewer artefacts (p = 0.004) and better visualization of pancreatic and bile ducts segments with the exception of the proximal CBD (p = 0.054), cystic duct confluence (p = 0.459), the four secondary intrahepatic bile ducts, and central part of the MPD (p = 0.885) for which no significant differences were found. Overall, diagnostic confidence was significantly better with the CS-BH-MRCP sequence for both readers (p = 0.038 and p = 0.038, respectively). This study shows that the CS-BH-MRCP sequence presents overall better image quality and bile and pancreatic ducts visualization compared to the conventional RT-MRCP sequence at 3T. MDPI 2021-10-13 /pmc/articles/PMC8534472/ /pubmed/34679584 http://dx.doi.org/10.3390/diagnostics11101886 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Chevallier, Olivier
Escande, Hélène
Ambarki, Khalid
Weiland, Elisabeth
Kuehn, Bernd
Guillen, Kévin
Manfredi, Sylvain
Gehin, Sophie
Blanc, Julie
Loffroy, Romaric
Single-Breath-Hold MRI-SPACE Cholangiopancreatography with Compressed Sensing versus Conventional Respiratory-Triggered MRI-SPACE Cholangiopancreatography at 3Tesla: Comparison of Image Quality and Diagnostic Confidence
title Single-Breath-Hold MRI-SPACE Cholangiopancreatography with Compressed Sensing versus Conventional Respiratory-Triggered MRI-SPACE Cholangiopancreatography at 3Tesla: Comparison of Image Quality and Diagnostic Confidence
title_full Single-Breath-Hold MRI-SPACE Cholangiopancreatography with Compressed Sensing versus Conventional Respiratory-Triggered MRI-SPACE Cholangiopancreatography at 3Tesla: Comparison of Image Quality and Diagnostic Confidence
title_fullStr Single-Breath-Hold MRI-SPACE Cholangiopancreatography with Compressed Sensing versus Conventional Respiratory-Triggered MRI-SPACE Cholangiopancreatography at 3Tesla: Comparison of Image Quality and Diagnostic Confidence
title_full_unstemmed Single-Breath-Hold MRI-SPACE Cholangiopancreatography with Compressed Sensing versus Conventional Respiratory-Triggered MRI-SPACE Cholangiopancreatography at 3Tesla: Comparison of Image Quality and Diagnostic Confidence
title_short Single-Breath-Hold MRI-SPACE Cholangiopancreatography with Compressed Sensing versus Conventional Respiratory-Triggered MRI-SPACE Cholangiopancreatography at 3Tesla: Comparison of Image Quality and Diagnostic Confidence
title_sort single-breath-hold mri-space cholangiopancreatography with compressed sensing versus conventional respiratory-triggered mri-space cholangiopancreatography at 3tesla: comparison of image quality and diagnostic confidence
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8534472/
https://www.ncbi.nlm.nih.gov/pubmed/34679584
http://dx.doi.org/10.3390/diagnostics11101886
work_keys_str_mv AT chevallierolivier singlebreathholdmrispacecholangiopancreatographywithcompressedsensingversusconventionalrespiratorytriggeredmrispacecholangiopancreatographyat3teslacomparisonofimagequalityanddiagnosticconfidence
AT escandehelene singlebreathholdmrispacecholangiopancreatographywithcompressedsensingversusconventionalrespiratorytriggeredmrispacecholangiopancreatographyat3teslacomparisonofimagequalityanddiagnosticconfidence
AT ambarkikhalid singlebreathholdmrispacecholangiopancreatographywithcompressedsensingversusconventionalrespiratorytriggeredmrispacecholangiopancreatographyat3teslacomparisonofimagequalityanddiagnosticconfidence
AT weilandelisabeth singlebreathholdmrispacecholangiopancreatographywithcompressedsensingversusconventionalrespiratorytriggeredmrispacecholangiopancreatographyat3teslacomparisonofimagequalityanddiagnosticconfidence
AT kuehnbernd singlebreathholdmrispacecholangiopancreatographywithcompressedsensingversusconventionalrespiratorytriggeredmrispacecholangiopancreatographyat3teslacomparisonofimagequalityanddiagnosticconfidence
AT guillenkevin singlebreathholdmrispacecholangiopancreatographywithcompressedsensingversusconventionalrespiratorytriggeredmrispacecholangiopancreatographyat3teslacomparisonofimagequalityanddiagnosticconfidence
AT manfredisylvain singlebreathholdmrispacecholangiopancreatographywithcompressedsensingversusconventionalrespiratorytriggeredmrispacecholangiopancreatographyat3teslacomparisonofimagequalityanddiagnosticconfidence
AT gehinsophie singlebreathholdmrispacecholangiopancreatographywithcompressedsensingversusconventionalrespiratorytriggeredmrispacecholangiopancreatographyat3teslacomparisonofimagequalityanddiagnosticconfidence
AT blancjulie singlebreathholdmrispacecholangiopancreatographywithcompressedsensingversusconventionalrespiratorytriggeredmrispacecholangiopancreatographyat3teslacomparisonofimagequalityanddiagnosticconfidence
AT loffroyromaric singlebreathholdmrispacecholangiopancreatographywithcompressedsensingversusconventionalrespiratorytriggeredmrispacecholangiopancreatographyat3teslacomparisonofimagequalityanddiagnosticconfidence