Cargando…

Single- and Dual-Source CT Myelography: Comparison of Radiation Exposure and Establishment of Diagnostic Reference Levels

CT myelography (CTM) is a diagnostic technique for the evaluation of various spinal pathologies, and plays an important role in diagnosis of different diseases such as spontaneous intracranial hypotension and postoperative cerebrospinal fluid leaks. The aims of this study were to examine radiation e...

Descripción completa

Detalles Bibliográficos
Autores principales: Zensen, Sebastian, Bos, Denise, Opitz, Marcel, Forsting, Michael, Guberina, Nika, Deuschl, Cornelius, Wetter, Axel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8534585/
https://www.ncbi.nlm.nih.gov/pubmed/34679507
http://dx.doi.org/10.3390/diagnostics11101809
_version_ 1784587588260069376
author Zensen, Sebastian
Bos, Denise
Opitz, Marcel
Forsting, Michael
Guberina, Nika
Deuschl, Cornelius
Wetter, Axel
author_facet Zensen, Sebastian
Bos, Denise
Opitz, Marcel
Forsting, Michael
Guberina, Nika
Deuschl, Cornelius
Wetter, Axel
author_sort Zensen, Sebastian
collection PubMed
description CT myelography (CTM) is a diagnostic technique for the evaluation of various spinal pathologies, and plays an important role in diagnosis of different diseases such as spontaneous intracranial hypotension and postoperative cerebrospinal fluid leaks. The aims of this study were to examine radiation exposure, establish diagnostic reference levels (DRLs) and compare radiation doses of single- and dual-source examinations and different CTM protocols. In this retrospective study, 183 CTMs comprising 155 single-source and 28 dual-source examinations, performed between May 2015 and December 2020, were analyzed. Dose data included 31 whole spine (A), 23 cervical (B), 10 thoracic (C), and 119 lumbar (D) CTMs. Radiation exposure was reported for volume-weighted CT dose index (CTDI(vol)) and dose-length product (DLP). Radiation doses for CTDI(vol) and DLP were distributed as follows (median, IQR): A: 7.44 mGy (6.01–11.17 mGy)/509.7 mGy·cm (382.4–682.9 mGy·cm), B: 9.31 mGy (7.20–14.64 mGy)/214.5 mGy·cm (153.7–308.2 mGy·cm), C: 6.80 mGy (6.14–8.26 mGy)/365.4 mGy·cm (222.8–432.4 mGy·cm), D: 11.02 mGy (7.97–14.89 mGy)/308.0 mGy·cm (224.7–413.7 mGy·cm). Local DRLs could be depicted as follows (CTDI(vol)/DLP): A: 11 mGy/683 mGy·cm, B: 15 mGy/308 mGy·cm, C: 8 mGy/432 mGy·cm, D: 15 mGy/414 mGy·cm. High image quality was achieved for all anatomical regions. Basically, radiation exposure of CTM differs according to anatomical location.
format Online
Article
Text
id pubmed-8534585
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-85345852021-10-23 Single- and Dual-Source CT Myelography: Comparison of Radiation Exposure and Establishment of Diagnostic Reference Levels Zensen, Sebastian Bos, Denise Opitz, Marcel Forsting, Michael Guberina, Nika Deuschl, Cornelius Wetter, Axel Diagnostics (Basel) Article CT myelography (CTM) is a diagnostic technique for the evaluation of various spinal pathologies, and plays an important role in diagnosis of different diseases such as spontaneous intracranial hypotension and postoperative cerebrospinal fluid leaks. The aims of this study were to examine radiation exposure, establish diagnostic reference levels (DRLs) and compare radiation doses of single- and dual-source examinations and different CTM protocols. In this retrospective study, 183 CTMs comprising 155 single-source and 28 dual-source examinations, performed between May 2015 and December 2020, were analyzed. Dose data included 31 whole spine (A), 23 cervical (B), 10 thoracic (C), and 119 lumbar (D) CTMs. Radiation exposure was reported for volume-weighted CT dose index (CTDI(vol)) and dose-length product (DLP). Radiation doses for CTDI(vol) and DLP were distributed as follows (median, IQR): A: 7.44 mGy (6.01–11.17 mGy)/509.7 mGy·cm (382.4–682.9 mGy·cm), B: 9.31 mGy (7.20–14.64 mGy)/214.5 mGy·cm (153.7–308.2 mGy·cm), C: 6.80 mGy (6.14–8.26 mGy)/365.4 mGy·cm (222.8–432.4 mGy·cm), D: 11.02 mGy (7.97–14.89 mGy)/308.0 mGy·cm (224.7–413.7 mGy·cm). Local DRLs could be depicted as follows (CTDI(vol)/DLP): A: 11 mGy/683 mGy·cm, B: 15 mGy/308 mGy·cm, C: 8 mGy/432 mGy·cm, D: 15 mGy/414 mGy·cm. High image quality was achieved for all anatomical regions. Basically, radiation exposure of CTM differs according to anatomical location. MDPI 2021-09-30 /pmc/articles/PMC8534585/ /pubmed/34679507 http://dx.doi.org/10.3390/diagnostics11101809 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zensen, Sebastian
Bos, Denise
Opitz, Marcel
Forsting, Michael
Guberina, Nika
Deuschl, Cornelius
Wetter, Axel
Single- and Dual-Source CT Myelography: Comparison of Radiation Exposure and Establishment of Diagnostic Reference Levels
title Single- and Dual-Source CT Myelography: Comparison of Radiation Exposure and Establishment of Diagnostic Reference Levels
title_full Single- and Dual-Source CT Myelography: Comparison of Radiation Exposure and Establishment of Diagnostic Reference Levels
title_fullStr Single- and Dual-Source CT Myelography: Comparison of Radiation Exposure and Establishment of Diagnostic Reference Levels
title_full_unstemmed Single- and Dual-Source CT Myelography: Comparison of Radiation Exposure and Establishment of Diagnostic Reference Levels
title_short Single- and Dual-Source CT Myelography: Comparison of Radiation Exposure and Establishment of Diagnostic Reference Levels
title_sort single- and dual-source ct myelography: comparison of radiation exposure and establishment of diagnostic reference levels
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8534585/
https://www.ncbi.nlm.nih.gov/pubmed/34679507
http://dx.doi.org/10.3390/diagnostics11101809
work_keys_str_mv AT zensensebastian singleanddualsourcectmyelographycomparisonofradiationexposureandestablishmentofdiagnosticreferencelevels
AT bosdenise singleanddualsourcectmyelographycomparisonofradiationexposureandestablishmentofdiagnosticreferencelevels
AT opitzmarcel singleanddualsourcectmyelographycomparisonofradiationexposureandestablishmentofdiagnosticreferencelevels
AT forstingmichael singleanddualsourcectmyelographycomparisonofradiationexposureandestablishmentofdiagnosticreferencelevels
AT guberinanika singleanddualsourcectmyelographycomparisonofradiationexposureandestablishmentofdiagnosticreferencelevels
AT deuschlcornelius singleanddualsourcectmyelographycomparisonofradiationexposureandestablishmentofdiagnosticreferencelevels
AT wetteraxel singleanddualsourcectmyelographycomparisonofradiationexposureandestablishmentofdiagnosticreferencelevels