Cargando…

Intraoperative Radiotherapy with Balloon-Based Electronic Brachytherapy System—A Systematic Review and First Bulgarian Experience in Breast Cancer Patients

(1) Background: We aimed to analyze currently available studies with intraoperative radiotherapy (IORT) as a choice of treatment where the Xoft Axxent(®) electronic brachytherapy (eBx) system was used as a single-dose irradiation and an exclusive radiotherapy approach at the time of surgery in patie...

Descripción completa

Detalles Bibliográficos
Autores principales: Kostova-Lefterova, Desislava, Vasileva-Slaveva, Mariela, Maslyankov, Svilen, Konsoulova, Assia, Atanasova, Margarita, Paycheva, Tsvetelina, Vlahova, Alexandrina, Genadieva-Yordanova, Marusya, Prodanova, Ginka, Zahariev, Zahari, Pavlov, Vasil, Todorov, Georgi, Vasilev, Boris, Angelov, Kostadin, Deliyski, Tashko, Petrova, Ivelina, Hitova, Desislava, Petrov, Ivo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8534590/
https://www.ncbi.nlm.nih.gov/pubmed/34677253
http://dx.doi.org/10.3390/curroncol28050335
_version_ 1784587589473271808
author Kostova-Lefterova, Desislava
Vasileva-Slaveva, Mariela
Maslyankov, Svilen
Konsoulova, Assia
Atanasova, Margarita
Paycheva, Tsvetelina
Vlahova, Alexandrina
Genadieva-Yordanova, Marusya
Prodanova, Ginka
Zahariev, Zahari
Pavlov, Vasil
Todorov, Georgi
Vasilev, Boris
Angelov, Kostadin
Deliyski, Tashko
Petrova, Ivelina
Hitova, Desislava
Petrov, Ivo
author_facet Kostova-Lefterova, Desislava
Vasileva-Slaveva, Mariela
Maslyankov, Svilen
Konsoulova, Assia
Atanasova, Margarita
Paycheva, Tsvetelina
Vlahova, Alexandrina
Genadieva-Yordanova, Marusya
Prodanova, Ginka
Zahariev, Zahari
Pavlov, Vasil
Todorov, Georgi
Vasilev, Boris
Angelov, Kostadin
Deliyski, Tashko
Petrova, Ivelina
Hitova, Desislava
Petrov, Ivo
author_sort Kostova-Lefterova, Desislava
collection PubMed
description (1) Background: We aimed to analyze currently available studies with intraoperative radiotherapy (IORT) as a choice of treatment where the Xoft Axxent(®) electronic brachytherapy (eBx) system was used as a single-dose irradiation and an exclusive radiotherapy approach at the time of surgery in patients with early breast cancer (EBC). We also compared the results of the systematic review to the Bulgarian experience. (2) Methods and Materials: We performed a systematic review of the studies published before February 2021, which investigate the application of a single-fraction 20 Gy radiation treatment, delivered at the time of lumpectomy in EBC patients with the Xoft Axxent(®) eBx System. A systematic search in PubMed, Scopus, and ScienceDirect was performed. The results are reported following the PRISMA guidelines. The criteria on patients’ selection for IORT (the additional need for EBRT), cosmetic outcomes, and recurrence rate from the eligible studies are compared to the treatment results in Bulgarian patients. (3) Results: We searched through 1032 results to find 17 eligible studies. There are no published outcomes from randomized trials. When reported, the cosmetic outcomes in most of the studies are defined as excellent. The observed recurrence rate is low (1–5.8%). Still, the number of patients additionally referred to postoperative external breast radiotherapy (EBRT) is up to 31%. Amongst the 20 patients treated in Bulgaria, the cosmetic outcomes are also evaluated as excellent, five of which (25%) are referred for EBRT. Within median follow-up of 39 months, there was one local and one distal recurrence. (4) Conclusions: Current evidence demonstrates the Xoft Axxent(®) eBx system as a safe and feasible technique for IORT delivery in EBC patients. There are no randomized controlled trials conducted at this time point to prove its long-term effectiveness. Better patient selection and a reimbursement strategy have to be proposed to extend the application of this technique in Bulgaria.
format Online
Article
Text
id pubmed-8534590
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-85345902021-10-23 Intraoperative Radiotherapy with Balloon-Based Electronic Brachytherapy System—A Systematic Review and First Bulgarian Experience in Breast Cancer Patients Kostova-Lefterova, Desislava Vasileva-Slaveva, Mariela Maslyankov, Svilen Konsoulova, Assia Atanasova, Margarita Paycheva, Tsvetelina Vlahova, Alexandrina Genadieva-Yordanova, Marusya Prodanova, Ginka Zahariev, Zahari Pavlov, Vasil Todorov, Georgi Vasilev, Boris Angelov, Kostadin Deliyski, Tashko Petrova, Ivelina Hitova, Desislava Petrov, Ivo Curr Oncol Systematic Review (1) Background: We aimed to analyze currently available studies with intraoperative radiotherapy (IORT) as a choice of treatment where the Xoft Axxent(®) electronic brachytherapy (eBx) system was used as a single-dose irradiation and an exclusive radiotherapy approach at the time of surgery in patients with early breast cancer (EBC). We also compared the results of the systematic review to the Bulgarian experience. (2) Methods and Materials: We performed a systematic review of the studies published before February 2021, which investigate the application of a single-fraction 20 Gy radiation treatment, delivered at the time of lumpectomy in EBC patients with the Xoft Axxent(®) eBx System. A systematic search in PubMed, Scopus, and ScienceDirect was performed. The results are reported following the PRISMA guidelines. The criteria on patients’ selection for IORT (the additional need for EBRT), cosmetic outcomes, and recurrence rate from the eligible studies are compared to the treatment results in Bulgarian patients. (3) Results: We searched through 1032 results to find 17 eligible studies. There are no published outcomes from randomized trials. When reported, the cosmetic outcomes in most of the studies are defined as excellent. The observed recurrence rate is low (1–5.8%). Still, the number of patients additionally referred to postoperative external breast radiotherapy (EBRT) is up to 31%. Amongst the 20 patients treated in Bulgaria, the cosmetic outcomes are also evaluated as excellent, five of which (25%) are referred for EBRT. Within median follow-up of 39 months, there was one local and one distal recurrence. (4) Conclusions: Current evidence demonstrates the Xoft Axxent(®) eBx system as a safe and feasible technique for IORT delivery in EBC patients. There are no randomized controlled trials conducted at this time point to prove its long-term effectiveness. Better patient selection and a reimbursement strategy have to be proposed to extend the application of this technique in Bulgaria. MDPI 2021-10-03 /pmc/articles/PMC8534590/ /pubmed/34677253 http://dx.doi.org/10.3390/curroncol28050335 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Systematic Review
Kostova-Lefterova, Desislava
Vasileva-Slaveva, Mariela
Maslyankov, Svilen
Konsoulova, Assia
Atanasova, Margarita
Paycheva, Tsvetelina
Vlahova, Alexandrina
Genadieva-Yordanova, Marusya
Prodanova, Ginka
Zahariev, Zahari
Pavlov, Vasil
Todorov, Georgi
Vasilev, Boris
Angelov, Kostadin
Deliyski, Tashko
Petrova, Ivelina
Hitova, Desislava
Petrov, Ivo
Intraoperative Radiotherapy with Balloon-Based Electronic Brachytherapy System—A Systematic Review and First Bulgarian Experience in Breast Cancer Patients
title Intraoperative Radiotherapy with Balloon-Based Electronic Brachytherapy System—A Systematic Review and First Bulgarian Experience in Breast Cancer Patients
title_full Intraoperative Radiotherapy with Balloon-Based Electronic Brachytherapy System—A Systematic Review and First Bulgarian Experience in Breast Cancer Patients
title_fullStr Intraoperative Radiotherapy with Balloon-Based Electronic Brachytherapy System—A Systematic Review and First Bulgarian Experience in Breast Cancer Patients
title_full_unstemmed Intraoperative Radiotherapy with Balloon-Based Electronic Brachytherapy System—A Systematic Review and First Bulgarian Experience in Breast Cancer Patients
title_short Intraoperative Radiotherapy with Balloon-Based Electronic Brachytherapy System—A Systematic Review and First Bulgarian Experience in Breast Cancer Patients
title_sort intraoperative radiotherapy with balloon-based electronic brachytherapy system—a systematic review and first bulgarian experience in breast cancer patients
topic Systematic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8534590/
https://www.ncbi.nlm.nih.gov/pubmed/34677253
http://dx.doi.org/10.3390/curroncol28050335
work_keys_str_mv AT kostovalefterovadesislava intraoperativeradiotherapywithballoonbasedelectronicbrachytherapysystemasystematicreviewandfirstbulgarianexperienceinbreastcancerpatients
AT vasilevaslavevamariela intraoperativeradiotherapywithballoonbasedelectronicbrachytherapysystemasystematicreviewandfirstbulgarianexperienceinbreastcancerpatients
AT maslyankovsvilen intraoperativeradiotherapywithballoonbasedelectronicbrachytherapysystemasystematicreviewandfirstbulgarianexperienceinbreastcancerpatients
AT konsoulovaassia intraoperativeradiotherapywithballoonbasedelectronicbrachytherapysystemasystematicreviewandfirstbulgarianexperienceinbreastcancerpatients
AT atanasovamargarita intraoperativeradiotherapywithballoonbasedelectronicbrachytherapysystemasystematicreviewandfirstbulgarianexperienceinbreastcancerpatients
AT paychevatsvetelina intraoperativeradiotherapywithballoonbasedelectronicbrachytherapysystemasystematicreviewandfirstbulgarianexperienceinbreastcancerpatients
AT vlahovaalexandrina intraoperativeradiotherapywithballoonbasedelectronicbrachytherapysystemasystematicreviewandfirstbulgarianexperienceinbreastcancerpatients
AT genadievayordanovamarusya intraoperativeradiotherapywithballoonbasedelectronicbrachytherapysystemasystematicreviewandfirstbulgarianexperienceinbreastcancerpatients
AT prodanovaginka intraoperativeradiotherapywithballoonbasedelectronicbrachytherapysystemasystematicreviewandfirstbulgarianexperienceinbreastcancerpatients
AT zaharievzahari intraoperativeradiotherapywithballoonbasedelectronicbrachytherapysystemasystematicreviewandfirstbulgarianexperienceinbreastcancerpatients
AT pavlovvasil intraoperativeradiotherapywithballoonbasedelectronicbrachytherapysystemasystematicreviewandfirstbulgarianexperienceinbreastcancerpatients
AT todorovgeorgi intraoperativeradiotherapywithballoonbasedelectronicbrachytherapysystemasystematicreviewandfirstbulgarianexperienceinbreastcancerpatients
AT vasilevboris intraoperativeradiotherapywithballoonbasedelectronicbrachytherapysystemasystematicreviewandfirstbulgarianexperienceinbreastcancerpatients
AT angelovkostadin intraoperativeradiotherapywithballoonbasedelectronicbrachytherapysystemasystematicreviewandfirstbulgarianexperienceinbreastcancerpatients
AT deliyskitashko intraoperativeradiotherapywithballoonbasedelectronicbrachytherapysystemasystematicreviewandfirstbulgarianexperienceinbreastcancerpatients
AT petrovaivelina intraoperativeradiotherapywithballoonbasedelectronicbrachytherapysystemasystematicreviewandfirstbulgarianexperienceinbreastcancerpatients
AT hitovadesislava intraoperativeradiotherapywithballoonbasedelectronicbrachytherapysystemasystematicreviewandfirstbulgarianexperienceinbreastcancerpatients
AT petrovivo intraoperativeradiotherapywithballoonbasedelectronicbrachytherapysystemasystematicreviewandfirstbulgarianexperienceinbreastcancerpatients