Evaluation of the New Beckmann Coulter Analyzer DxH 900 Compared to Sysmex XN20: Analytical Performance and Flagging Efficiency

Efficiency and accuracy in automated hematology analyzers are very important for clinical laboratories. The purpose was to evaluate the flags and results reported by the newest Beckman Coulter analyzer DxH 900 compared to the Sysmex XN20 system. Samples were analyzed on the XN20 (Sysmex, Kobe, Japan...

Descripción completa

Detalles Bibliográficos
Autores principales: Serrando Querol, Maite, Nieto-Moragas, Javier, Marull Arnall, Anna, Figueras, Meritxell Deulofeu, Jiménez-Romero, Orlando
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8535162/
https://www.ncbi.nlm.nih.gov/pubmed/34679454
http://dx.doi.org/10.3390/diagnostics11101756
_version_ 1784587712580288512
author Serrando Querol, Maite
Nieto-Moragas, Javier
Marull Arnall, Anna
Figueras, Meritxell Deulofeu
Jiménez-Romero, Orlando
author_facet Serrando Querol, Maite
Nieto-Moragas, Javier
Marull Arnall, Anna
Figueras, Meritxell Deulofeu
Jiménez-Romero, Orlando
author_sort Serrando Querol, Maite
collection PubMed
description Efficiency and accuracy in automated hematology analyzers are very important for clinical laboratories. The purpose was to evaluate the flags and results reported by the newest Beckman Coulter analyzer DxH 900 compared to the Sysmex XN20 system. Samples were analyzed on the XN20 (Sysmex, Kobe, Japan) and on the Beckman Coulter DxH 900 (Beckman Coulter, Miami, Florida, USA). Slide reviews were performed microscopically. Morphologic criteria were used to identify abnormal cells as recommended by International Consensus Group for Hematology (ICSH): blasts, immature granulocytes (IG%), abnormal lymphocytes (ALs) and plasma cells. Results: there was a strong correlation between the analyzers in almost all clinical parameters tested. Both DxH 900 and XN20 showed an excellent degree of association for the leukocyte differential compared to the reference method (manual microscopy). When it comes to IG%, XN20 showed a positive bias for higher results. Related to platelets, there are no differences between the two methods for PLT count. For mean platelet volume (MPV), DxH 900 provided 100% results of the samples analyzed while XN20 while in the XN20 analyzer, 16% of the results were missing. From our results we came to the conclusion that both analyzers, DxH 900 and XN20 were clinically accurate and efficient. Abnormal Lymphocyte detection highlighted the differences between the two technologies as only minimal agreement was obtained. DxH 900 demonstrated higher sensitivity in detecting IG with good correlation with microscopic review. The DxH 900 for platelet clumps identification provides an excellent flag (PLT Clumps) with the highest sensitivity observed in our evaluation.
format Online
Article
Text
id pubmed-8535162
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-85351622021-10-23 Evaluation of the New Beckmann Coulter Analyzer DxH 900 Compared to Sysmex XN20: Analytical Performance and Flagging Efficiency Serrando Querol, Maite Nieto-Moragas, Javier Marull Arnall, Anna Figueras, Meritxell Deulofeu Jiménez-Romero, Orlando Diagnostics (Basel) Article Efficiency and accuracy in automated hematology analyzers are very important for clinical laboratories. The purpose was to evaluate the flags and results reported by the newest Beckman Coulter analyzer DxH 900 compared to the Sysmex XN20 system. Samples were analyzed on the XN20 (Sysmex, Kobe, Japan) and on the Beckman Coulter DxH 900 (Beckman Coulter, Miami, Florida, USA). Slide reviews were performed microscopically. Morphologic criteria were used to identify abnormal cells as recommended by International Consensus Group for Hematology (ICSH): blasts, immature granulocytes (IG%), abnormal lymphocytes (ALs) and plasma cells. Results: there was a strong correlation between the analyzers in almost all clinical parameters tested. Both DxH 900 and XN20 showed an excellent degree of association for the leukocyte differential compared to the reference method (manual microscopy). When it comes to IG%, XN20 showed a positive bias for higher results. Related to platelets, there are no differences between the two methods for PLT count. For mean platelet volume (MPV), DxH 900 provided 100% results of the samples analyzed while XN20 while in the XN20 analyzer, 16% of the results were missing. From our results we came to the conclusion that both analyzers, DxH 900 and XN20 were clinically accurate and efficient. Abnormal Lymphocyte detection highlighted the differences between the two technologies as only minimal agreement was obtained. DxH 900 demonstrated higher sensitivity in detecting IG with good correlation with microscopic review. The DxH 900 for platelet clumps identification provides an excellent flag (PLT Clumps) with the highest sensitivity observed in our evaluation. MDPI 2021-09-24 /pmc/articles/PMC8535162/ /pubmed/34679454 http://dx.doi.org/10.3390/diagnostics11101756 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Serrando Querol, Maite
Nieto-Moragas, Javier
Marull Arnall, Anna
Figueras, Meritxell Deulofeu
Jiménez-Romero, Orlando
Evaluation of the New Beckmann Coulter Analyzer DxH 900 Compared to Sysmex XN20: Analytical Performance and Flagging Efficiency
title Evaluation of the New Beckmann Coulter Analyzer DxH 900 Compared to Sysmex XN20: Analytical Performance and Flagging Efficiency
title_full Evaluation of the New Beckmann Coulter Analyzer DxH 900 Compared to Sysmex XN20: Analytical Performance and Flagging Efficiency
title_fullStr Evaluation of the New Beckmann Coulter Analyzer DxH 900 Compared to Sysmex XN20: Analytical Performance and Flagging Efficiency
title_full_unstemmed Evaluation of the New Beckmann Coulter Analyzer DxH 900 Compared to Sysmex XN20: Analytical Performance and Flagging Efficiency
title_short Evaluation of the New Beckmann Coulter Analyzer DxH 900 Compared to Sysmex XN20: Analytical Performance and Flagging Efficiency
title_sort evaluation of the new beckmann coulter analyzer dxh 900 compared to sysmex xn20: analytical performance and flagging efficiency
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8535162/
https://www.ncbi.nlm.nih.gov/pubmed/34679454
http://dx.doi.org/10.3390/diagnostics11101756
work_keys_str_mv AT serrandoquerolmaite evaluationofthenewbeckmanncoulteranalyzerdxh900comparedtosysmexxn20analyticalperformanceandflaggingefficiency
AT nietomoragasjavier evaluationofthenewbeckmanncoulteranalyzerdxh900comparedtosysmexxn20analyticalperformanceandflaggingefficiency
AT marullarnallanna evaluationofthenewbeckmanncoulteranalyzerdxh900comparedtosysmexxn20analyticalperformanceandflaggingefficiency
AT figuerasmeritxelldeulofeu evaluationofthenewbeckmanncoulteranalyzerdxh900comparedtosysmexxn20analyticalperformanceandflaggingefficiency
AT jimenezromeroorlando evaluationofthenewbeckmanncoulteranalyzerdxh900comparedtosysmexxn20analyticalperformanceandflaggingefficiency