Cargando…

Total Fat Gravimetric Method Workflow in Portuguese Olives Using Closed-Vessel Microwave-Assisted Extraction (MAE)

A simple and rapid method for the quantitation of total fat in olive samples is designed, evaluated, and presented. This method is based on an innovative closed-vessel microwave-assisted extraction (MAE) technique. A method was designed for olives, and some figures of merits were evaluated: limit of...

Descripción completa

Detalles Bibliográficos
Autores principales: Lourenço, João Gonçalo, Ettlin, Daniel, Cardoso, Inês Carrero, Rodilla, Jesus M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8535687/
https://www.ncbi.nlm.nih.gov/pubmed/34681413
http://dx.doi.org/10.3390/foods10102364
_version_ 1784587844892753920
author Lourenço, João Gonçalo
Ettlin, Daniel
Cardoso, Inês Carrero
Rodilla, Jesus M.
author_facet Lourenço, João Gonçalo
Ettlin, Daniel
Cardoso, Inês Carrero
Rodilla, Jesus M.
author_sort Lourenço, João Gonçalo
collection PubMed
description A simple and rapid method for the quantitation of total fat in olive samples is designed, evaluated, and presented. This method is based on an innovative closed-vessel microwave-assisted extraction (MAE) technique. A method was designed for olives, and some figures of merits were evaluated: limit of detection (LOD), limit of quantification (LOQ) and expanded uncertainty (U). The data obtained in these experiences show that the workflow of the MAE method in a closed container is statistically equivalent to the other two methods, showing in this case better performance indicators (LOD = 0.02%, LOQ = 0.06%, and U = 15%). In addition, it is also demonstrated that the complete MAE method workflow allows the determination of total fat in a maximum of 12 analyses simultaneously for about 100 min in each run, which is the capacity of the rotor. This is a much better productivity when compared to the traditional Soxhlet-based method. Considering the sample workflow, the closed-vessel MAE method greatly simplifies sample handling, therefore minimizing sample loss during sample preparation and reducing analysis time. When MAE is compared to NIR-based methods, the advantage comes from there being no need for any type of calibration in the sample matrix. The MAE method itself can be used to determine the reference value for NIR calibration purposes. The results obtained for CRM using MAE were equivalent to the ones shown on the certificate.
format Online
Article
Text
id pubmed-8535687
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-85356872021-10-23 Total Fat Gravimetric Method Workflow in Portuguese Olives Using Closed-Vessel Microwave-Assisted Extraction (MAE) Lourenço, João Gonçalo Ettlin, Daniel Cardoso, Inês Carrero Rodilla, Jesus M. Foods Article A simple and rapid method for the quantitation of total fat in olive samples is designed, evaluated, and presented. This method is based on an innovative closed-vessel microwave-assisted extraction (MAE) technique. A method was designed for olives, and some figures of merits were evaluated: limit of detection (LOD), limit of quantification (LOQ) and expanded uncertainty (U). The data obtained in these experiences show that the workflow of the MAE method in a closed container is statistically equivalent to the other two methods, showing in this case better performance indicators (LOD = 0.02%, LOQ = 0.06%, and U = 15%). In addition, it is also demonstrated that the complete MAE method workflow allows the determination of total fat in a maximum of 12 analyses simultaneously for about 100 min in each run, which is the capacity of the rotor. This is a much better productivity when compared to the traditional Soxhlet-based method. Considering the sample workflow, the closed-vessel MAE method greatly simplifies sample handling, therefore minimizing sample loss during sample preparation and reducing analysis time. When MAE is compared to NIR-based methods, the advantage comes from there being no need for any type of calibration in the sample matrix. The MAE method itself can be used to determine the reference value for NIR calibration purposes. The results obtained for CRM using MAE were equivalent to the ones shown on the certificate. MDPI 2021-10-04 /pmc/articles/PMC8535687/ /pubmed/34681413 http://dx.doi.org/10.3390/foods10102364 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lourenço, João Gonçalo
Ettlin, Daniel
Cardoso, Inês Carrero
Rodilla, Jesus M.
Total Fat Gravimetric Method Workflow in Portuguese Olives Using Closed-Vessel Microwave-Assisted Extraction (MAE)
title Total Fat Gravimetric Method Workflow in Portuguese Olives Using Closed-Vessel Microwave-Assisted Extraction (MAE)
title_full Total Fat Gravimetric Method Workflow in Portuguese Olives Using Closed-Vessel Microwave-Assisted Extraction (MAE)
title_fullStr Total Fat Gravimetric Method Workflow in Portuguese Olives Using Closed-Vessel Microwave-Assisted Extraction (MAE)
title_full_unstemmed Total Fat Gravimetric Method Workflow in Portuguese Olives Using Closed-Vessel Microwave-Assisted Extraction (MAE)
title_short Total Fat Gravimetric Method Workflow in Portuguese Olives Using Closed-Vessel Microwave-Assisted Extraction (MAE)
title_sort total fat gravimetric method workflow in portuguese olives using closed-vessel microwave-assisted extraction (mae)
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8535687/
https://www.ncbi.nlm.nih.gov/pubmed/34681413
http://dx.doi.org/10.3390/foods10102364
work_keys_str_mv AT lourencojoaogoncalo totalfatgravimetricmethodworkflowinportugueseolivesusingclosedvesselmicrowaveassistedextractionmae
AT ettlindaniel totalfatgravimetricmethodworkflowinportugueseolivesusingclosedvesselmicrowaveassistedextractionmae
AT cardosoinescarrero totalfatgravimetricmethodworkflowinportugueseolivesusingclosedvesselmicrowaveassistedextractionmae
AT rodillajesusm totalfatgravimetricmethodworkflowinportugueseolivesusingclosedvesselmicrowaveassistedextractionmae