Cargando…

Hydroxyapatite Particles from Simulated Body Fluids with Different pH and Their Effects on Mesenchymal Stem Cells

Bone-like hydroxyapatite (HAp) has been prepared by biomimetic synthesis using simulated body fluid (SBF), mimicking inorganic ion concentrations in human plasma, or 1.5SBF that has 1.5-times higher ion concentrations than SBF. In this study, the controllable preparations of HAp particles from 1.5SB...

Descripción completa

Detalles Bibliográficos
Autores principales: Miyajima, Hiroki, Touji, Hiroki, Iijima, Kazutoshi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8538532/
https://www.ncbi.nlm.nih.gov/pubmed/34684958
http://dx.doi.org/10.3390/nano11102517
_version_ 1784588528790798336
author Miyajima, Hiroki
Touji, Hiroki
Iijima, Kazutoshi
author_facet Miyajima, Hiroki
Touji, Hiroki
Iijima, Kazutoshi
author_sort Miyajima, Hiroki
collection PubMed
description Bone-like hydroxyapatite (HAp) has been prepared by biomimetic synthesis using simulated body fluid (SBF), mimicking inorganic ion concentrations in human plasma, or 1.5SBF that has 1.5-times higher ion concentrations than SBF. In this study, the controllable preparations of HAp particles from 1.5SBF with different pH values were examined. The particles obtained as precipitates from 1.5SBF showed different morphologies and crystallinities depending on the pH of 1.5SBF. Micro-sized particles at pH 7.4 of 1.5SBF had a higher Ca/P ratio and crystallinity as compared with nano-sized particles at pH 8.0 and pH 8.4 of 1.5SBF. However, a mixture of micro-sized and nano-sized particles was obtained from pH 7.7 of 1.5SBF. When Ca(2+) concentrations in 1.5SBF during mineralization were monitored, the concentration at pH 7.4 drastically decreased from 12 to 24 h. At higher pH, such as 8.0 and 8.4, the Ca(2+) concentrations decreased during pH adjustment and slightly decreased even after 48 h. In this investigation at pH 7.7, the Ca(2+) concentrations were higher than pH 8.0 and 8.4.Additionally, cytotoxicity of the obtained precipitates to mesenchymal stem cells was lower than that of synthetic HAp. Controllable preparation HAp particles from SBF has potential applications in the construction of building components of cell scaffolds.
format Online
Article
Text
id pubmed-8538532
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-85385322021-10-24 Hydroxyapatite Particles from Simulated Body Fluids with Different pH and Their Effects on Mesenchymal Stem Cells Miyajima, Hiroki Touji, Hiroki Iijima, Kazutoshi Nanomaterials (Basel) Article Bone-like hydroxyapatite (HAp) has been prepared by biomimetic synthesis using simulated body fluid (SBF), mimicking inorganic ion concentrations in human plasma, or 1.5SBF that has 1.5-times higher ion concentrations than SBF. In this study, the controllable preparations of HAp particles from 1.5SBF with different pH values were examined. The particles obtained as precipitates from 1.5SBF showed different morphologies and crystallinities depending on the pH of 1.5SBF. Micro-sized particles at pH 7.4 of 1.5SBF had a higher Ca/P ratio and crystallinity as compared with nano-sized particles at pH 8.0 and pH 8.4 of 1.5SBF. However, a mixture of micro-sized and nano-sized particles was obtained from pH 7.7 of 1.5SBF. When Ca(2+) concentrations in 1.5SBF during mineralization were monitored, the concentration at pH 7.4 drastically decreased from 12 to 24 h. At higher pH, such as 8.0 and 8.4, the Ca(2+) concentrations decreased during pH adjustment and slightly decreased even after 48 h. In this investigation at pH 7.7, the Ca(2+) concentrations were higher than pH 8.0 and 8.4.Additionally, cytotoxicity of the obtained precipitates to mesenchymal stem cells was lower than that of synthetic HAp. Controllable preparation HAp particles from SBF has potential applications in the construction of building components of cell scaffolds. MDPI 2021-09-27 /pmc/articles/PMC8538532/ /pubmed/34684958 http://dx.doi.org/10.3390/nano11102517 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Miyajima, Hiroki
Touji, Hiroki
Iijima, Kazutoshi
Hydroxyapatite Particles from Simulated Body Fluids with Different pH and Their Effects on Mesenchymal Stem Cells
title Hydroxyapatite Particles from Simulated Body Fluids with Different pH and Their Effects on Mesenchymal Stem Cells
title_full Hydroxyapatite Particles from Simulated Body Fluids with Different pH and Their Effects on Mesenchymal Stem Cells
title_fullStr Hydroxyapatite Particles from Simulated Body Fluids with Different pH and Their Effects on Mesenchymal Stem Cells
title_full_unstemmed Hydroxyapatite Particles from Simulated Body Fluids with Different pH and Their Effects on Mesenchymal Stem Cells
title_short Hydroxyapatite Particles from Simulated Body Fluids with Different pH and Their Effects on Mesenchymal Stem Cells
title_sort hydroxyapatite particles from simulated body fluids with different ph and their effects on mesenchymal stem cells
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8538532/
https://www.ncbi.nlm.nih.gov/pubmed/34684958
http://dx.doi.org/10.3390/nano11102517
work_keys_str_mv AT miyajimahiroki hydroxyapatiteparticlesfromsimulatedbodyfluidswithdifferentphandtheireffectsonmesenchymalstemcells
AT toujihiroki hydroxyapatiteparticlesfromsimulatedbodyfluidswithdifferentphandtheireffectsonmesenchymalstemcells
AT iijimakazutoshi hydroxyapatiteparticlesfromsimulatedbodyfluidswithdifferentphandtheireffectsonmesenchymalstemcells