Cargando…

On-Site Calibration Method for Line-Structured Light Sensor-Based Railway Wheel Size Measurement System

Line-structured light has been widely used in the field of railway measurement, owing to its high capability of anti-interference, fast scanning speed and high accuracy. Traditional calibration methods of line-structured light sensors have the disadvantages of long calibration time and complicated c...

Descripción completa

Detalles Bibliográficos
Autores principales: Ran, Yunfeng, He, Qixin, Feng, Qibo, Cui, Jianying
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8538857/
https://www.ncbi.nlm.nih.gov/pubmed/34695929
http://dx.doi.org/10.3390/s21206717
_version_ 1784588607204360192
author Ran, Yunfeng
He, Qixin
Feng, Qibo
Cui, Jianying
author_facet Ran, Yunfeng
He, Qixin
Feng, Qibo
Cui, Jianying
author_sort Ran, Yunfeng
collection PubMed
description Line-structured light has been widely used in the field of railway measurement, owing to its high capability of anti-interference, fast scanning speed and high accuracy. Traditional calibration methods of line-structured light sensors have the disadvantages of long calibration time and complicated calibration process, which is not suitable for railway field application. In this paper, a fast calibration method based on a self-developed calibration device was proposed. Compared with traditional methods, the calibration process is simplified and the calibration time is greatly shortened. This method does not need to extract light strips; thus, the influence of ambient light on the measurement is reduced. In addition, the calibration error resulting from the misalignment was corrected by epipolar constraint, and the calibration accuracy was improved. Calibration experiments in laboratory and field tests were conducted to verify the effectiveness of this method, and the results showed that the proposed method can achieve a better calibration accuracy compared to a traditional calibration method based on Zhang’s method.
format Online
Article
Text
id pubmed-8538857
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-85388572021-10-24 On-Site Calibration Method for Line-Structured Light Sensor-Based Railway Wheel Size Measurement System Ran, Yunfeng He, Qixin Feng, Qibo Cui, Jianying Sensors (Basel) Article Line-structured light has been widely used in the field of railway measurement, owing to its high capability of anti-interference, fast scanning speed and high accuracy. Traditional calibration methods of line-structured light sensors have the disadvantages of long calibration time and complicated calibration process, which is not suitable for railway field application. In this paper, a fast calibration method based on a self-developed calibration device was proposed. Compared with traditional methods, the calibration process is simplified and the calibration time is greatly shortened. This method does not need to extract light strips; thus, the influence of ambient light on the measurement is reduced. In addition, the calibration error resulting from the misalignment was corrected by epipolar constraint, and the calibration accuracy was improved. Calibration experiments in laboratory and field tests were conducted to verify the effectiveness of this method, and the results showed that the proposed method can achieve a better calibration accuracy compared to a traditional calibration method based on Zhang’s method. MDPI 2021-10-09 /pmc/articles/PMC8538857/ /pubmed/34695929 http://dx.doi.org/10.3390/s21206717 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ran, Yunfeng
He, Qixin
Feng, Qibo
Cui, Jianying
On-Site Calibration Method for Line-Structured Light Sensor-Based Railway Wheel Size Measurement System
title On-Site Calibration Method for Line-Structured Light Sensor-Based Railway Wheel Size Measurement System
title_full On-Site Calibration Method for Line-Structured Light Sensor-Based Railway Wheel Size Measurement System
title_fullStr On-Site Calibration Method for Line-Structured Light Sensor-Based Railway Wheel Size Measurement System
title_full_unstemmed On-Site Calibration Method for Line-Structured Light Sensor-Based Railway Wheel Size Measurement System
title_short On-Site Calibration Method for Line-Structured Light Sensor-Based Railway Wheel Size Measurement System
title_sort on-site calibration method for line-structured light sensor-based railway wheel size measurement system
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8538857/
https://www.ncbi.nlm.nih.gov/pubmed/34695929
http://dx.doi.org/10.3390/s21206717
work_keys_str_mv AT ranyunfeng onsitecalibrationmethodforlinestructuredlightsensorbasedrailwaywheelsizemeasurementsystem
AT heqixin onsitecalibrationmethodforlinestructuredlightsensorbasedrailwaywheelsizemeasurementsystem
AT fengqibo onsitecalibrationmethodforlinestructuredlightsensorbasedrailwaywheelsizemeasurementsystem
AT cuijianying onsitecalibrationmethodforlinestructuredlightsensorbasedrailwaywheelsizemeasurementsystem