Cargando…

Pre-Heating Effect on Monomer Elution and Degree of Conversion of Contemporary and Thermoviscous Bulk-Fill Resin-Based Dental Composites

Detection of unreacted monomers from pre-heated resin-based dental composites (RBC) is not a well-investigated topic so far. The objectives were to determine the temperature changes during the application and polymerization, the degree of conversion (DC) and unreacted monomer elution of room tempera...

Descripción completa

Detalles Bibliográficos
Autores principales: Kincses, Dóra, Böddi, Katalin, Őri, Zsuzsanna, Lovász, Bálint Viktor, Jeges, Sára, Szalma, József, Kunsági-Máté, Sándor, Lempel, Edina
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8538921/
https://www.ncbi.nlm.nih.gov/pubmed/34685358
http://dx.doi.org/10.3390/polym13203599
_version_ 1784588621829898240
author Kincses, Dóra
Böddi, Katalin
Őri, Zsuzsanna
Lovász, Bálint Viktor
Jeges, Sára
Szalma, József
Kunsági-Máté, Sándor
Lempel, Edina
author_facet Kincses, Dóra
Böddi, Katalin
Őri, Zsuzsanna
Lovász, Bálint Viktor
Jeges, Sára
Szalma, József
Kunsági-Máté, Sándor
Lempel, Edina
author_sort Kincses, Dóra
collection PubMed
description Detection of unreacted monomers from pre-heated resin-based dental composites (RBC) is not a well-investigated topic so far. The objectives were to determine the temperature changes during the application and polymerization, the degree of conversion (DC) and unreacted monomer elution of room temperature (RT), and pre-heated thermoviscous [VisCalor Bulk(VCB)] and high-viscosity full-body contemporary [Filtek One Bulk(FOB)] bulk-fill RBCs. The RBCs’ temperatures during the sample preparation were recorded with a K-type thermocouple. The DC at the top and bottom was measured with micro-Raman spectroscopy and the amounts of eluted BisGMA, UDMA, DDMA, and TEGDMA were assessed with High-Performance Liquid Chromatography. The temperatures of the pre-heated RBCs decreased rapidly during the manipulation phase. The temperature rise during photopolymerization reflects the bottom DCs. The differences in DC% between the top and the bottom were significant. RT VCB had a lower DC% compared to FOB. Pre-heating did not influence the DC, except on the bottom surface of FOB where a significant decrease was measured. Pre-heating significantly decreased the elution of BisGMA, UDMA, DDMA in the case of FOB, meanwhile, it had no effect on monomer release from VCB, except TEGDMA, which elution was decreased. In comparison, RBC composition had a stronger influence on DC and monomer elution, than pre-cure temperature.
format Online
Article
Text
id pubmed-8538921
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-85389212021-10-24 Pre-Heating Effect on Monomer Elution and Degree of Conversion of Contemporary and Thermoviscous Bulk-Fill Resin-Based Dental Composites Kincses, Dóra Böddi, Katalin Őri, Zsuzsanna Lovász, Bálint Viktor Jeges, Sára Szalma, József Kunsági-Máté, Sándor Lempel, Edina Polymers (Basel) Article Detection of unreacted monomers from pre-heated resin-based dental composites (RBC) is not a well-investigated topic so far. The objectives were to determine the temperature changes during the application and polymerization, the degree of conversion (DC) and unreacted monomer elution of room temperature (RT), and pre-heated thermoviscous [VisCalor Bulk(VCB)] and high-viscosity full-body contemporary [Filtek One Bulk(FOB)] bulk-fill RBCs. The RBCs’ temperatures during the sample preparation were recorded with a K-type thermocouple. The DC at the top and bottom was measured with micro-Raman spectroscopy and the amounts of eluted BisGMA, UDMA, DDMA, and TEGDMA were assessed with High-Performance Liquid Chromatography. The temperatures of the pre-heated RBCs decreased rapidly during the manipulation phase. The temperature rise during photopolymerization reflects the bottom DCs. The differences in DC% between the top and the bottom were significant. RT VCB had a lower DC% compared to FOB. Pre-heating did not influence the DC, except on the bottom surface of FOB where a significant decrease was measured. Pre-heating significantly decreased the elution of BisGMA, UDMA, DDMA in the case of FOB, meanwhile, it had no effect on monomer release from VCB, except TEGDMA, which elution was decreased. In comparison, RBC composition had a stronger influence on DC and monomer elution, than pre-cure temperature. MDPI 2021-10-19 /pmc/articles/PMC8538921/ /pubmed/34685358 http://dx.doi.org/10.3390/polym13203599 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kincses, Dóra
Böddi, Katalin
Őri, Zsuzsanna
Lovász, Bálint Viktor
Jeges, Sára
Szalma, József
Kunsági-Máté, Sándor
Lempel, Edina
Pre-Heating Effect on Monomer Elution and Degree of Conversion of Contemporary and Thermoviscous Bulk-Fill Resin-Based Dental Composites
title Pre-Heating Effect on Monomer Elution and Degree of Conversion of Contemporary and Thermoviscous Bulk-Fill Resin-Based Dental Composites
title_full Pre-Heating Effect on Monomer Elution and Degree of Conversion of Contemporary and Thermoviscous Bulk-Fill Resin-Based Dental Composites
title_fullStr Pre-Heating Effect on Monomer Elution and Degree of Conversion of Contemporary and Thermoviscous Bulk-Fill Resin-Based Dental Composites
title_full_unstemmed Pre-Heating Effect on Monomer Elution and Degree of Conversion of Contemporary and Thermoviscous Bulk-Fill Resin-Based Dental Composites
title_short Pre-Heating Effect on Monomer Elution and Degree of Conversion of Contemporary and Thermoviscous Bulk-Fill Resin-Based Dental Composites
title_sort pre-heating effect on monomer elution and degree of conversion of contemporary and thermoviscous bulk-fill resin-based dental composites
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8538921/
https://www.ncbi.nlm.nih.gov/pubmed/34685358
http://dx.doi.org/10.3390/polym13203599
work_keys_str_mv AT kincsesdora preheatingeffectonmonomerelutionanddegreeofconversionofcontemporaryandthermoviscousbulkfillresinbaseddentalcomposites
AT boddikatalin preheatingeffectonmonomerelutionanddegreeofconversionofcontemporaryandthermoviscousbulkfillresinbaseddentalcomposites
AT orizsuzsanna preheatingeffectonmonomerelutionanddegreeofconversionofcontemporaryandthermoviscousbulkfillresinbaseddentalcomposites
AT lovaszbalintviktor preheatingeffectonmonomerelutionanddegreeofconversionofcontemporaryandthermoviscousbulkfillresinbaseddentalcomposites
AT jegessara preheatingeffectonmonomerelutionanddegreeofconversionofcontemporaryandthermoviscousbulkfillresinbaseddentalcomposites
AT szalmajozsef preheatingeffectonmonomerelutionanddegreeofconversionofcontemporaryandthermoviscousbulkfillresinbaseddentalcomposites
AT kunsagimatesandor preheatingeffectonmonomerelutionanddegreeofconversionofcontemporaryandthermoviscousbulkfillresinbaseddentalcomposites
AT lempeledina preheatingeffectonmonomerelutionanddegreeofconversionofcontemporaryandthermoviscousbulkfillresinbaseddentalcomposites