Cargando…
Pre-Heating Effect on Monomer Elution and Degree of Conversion of Contemporary and Thermoviscous Bulk-Fill Resin-Based Dental Composites
Detection of unreacted monomers from pre-heated resin-based dental composites (RBC) is not a well-investigated topic so far. The objectives were to determine the temperature changes during the application and polymerization, the degree of conversion (DC) and unreacted monomer elution of room tempera...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8538921/ https://www.ncbi.nlm.nih.gov/pubmed/34685358 http://dx.doi.org/10.3390/polym13203599 |
_version_ | 1784588621829898240 |
---|---|
author | Kincses, Dóra Böddi, Katalin Őri, Zsuzsanna Lovász, Bálint Viktor Jeges, Sára Szalma, József Kunsági-Máté, Sándor Lempel, Edina |
author_facet | Kincses, Dóra Böddi, Katalin Őri, Zsuzsanna Lovász, Bálint Viktor Jeges, Sára Szalma, József Kunsági-Máté, Sándor Lempel, Edina |
author_sort | Kincses, Dóra |
collection | PubMed |
description | Detection of unreacted monomers from pre-heated resin-based dental composites (RBC) is not a well-investigated topic so far. The objectives were to determine the temperature changes during the application and polymerization, the degree of conversion (DC) and unreacted monomer elution of room temperature (RT), and pre-heated thermoviscous [VisCalor Bulk(VCB)] and high-viscosity full-body contemporary [Filtek One Bulk(FOB)] bulk-fill RBCs. The RBCs’ temperatures during the sample preparation were recorded with a K-type thermocouple. The DC at the top and bottom was measured with micro-Raman spectroscopy and the amounts of eluted BisGMA, UDMA, DDMA, and TEGDMA were assessed with High-Performance Liquid Chromatography. The temperatures of the pre-heated RBCs decreased rapidly during the manipulation phase. The temperature rise during photopolymerization reflects the bottom DCs. The differences in DC% between the top and the bottom were significant. RT VCB had a lower DC% compared to FOB. Pre-heating did not influence the DC, except on the bottom surface of FOB where a significant decrease was measured. Pre-heating significantly decreased the elution of BisGMA, UDMA, DDMA in the case of FOB, meanwhile, it had no effect on monomer release from VCB, except TEGDMA, which elution was decreased. In comparison, RBC composition had a stronger influence on DC and monomer elution, than pre-cure temperature. |
format | Online Article Text |
id | pubmed-8538921 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-85389212021-10-24 Pre-Heating Effect on Monomer Elution and Degree of Conversion of Contemporary and Thermoviscous Bulk-Fill Resin-Based Dental Composites Kincses, Dóra Böddi, Katalin Őri, Zsuzsanna Lovász, Bálint Viktor Jeges, Sára Szalma, József Kunsági-Máté, Sándor Lempel, Edina Polymers (Basel) Article Detection of unreacted monomers from pre-heated resin-based dental composites (RBC) is not a well-investigated topic so far. The objectives were to determine the temperature changes during the application and polymerization, the degree of conversion (DC) and unreacted monomer elution of room temperature (RT), and pre-heated thermoviscous [VisCalor Bulk(VCB)] and high-viscosity full-body contemporary [Filtek One Bulk(FOB)] bulk-fill RBCs. The RBCs’ temperatures during the sample preparation were recorded with a K-type thermocouple. The DC at the top and bottom was measured with micro-Raman spectroscopy and the amounts of eluted BisGMA, UDMA, DDMA, and TEGDMA were assessed with High-Performance Liquid Chromatography. The temperatures of the pre-heated RBCs decreased rapidly during the manipulation phase. The temperature rise during photopolymerization reflects the bottom DCs. The differences in DC% between the top and the bottom were significant. RT VCB had a lower DC% compared to FOB. Pre-heating did not influence the DC, except on the bottom surface of FOB where a significant decrease was measured. Pre-heating significantly decreased the elution of BisGMA, UDMA, DDMA in the case of FOB, meanwhile, it had no effect on monomer release from VCB, except TEGDMA, which elution was decreased. In comparison, RBC composition had a stronger influence on DC and monomer elution, than pre-cure temperature. MDPI 2021-10-19 /pmc/articles/PMC8538921/ /pubmed/34685358 http://dx.doi.org/10.3390/polym13203599 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Kincses, Dóra Böddi, Katalin Őri, Zsuzsanna Lovász, Bálint Viktor Jeges, Sára Szalma, József Kunsági-Máté, Sándor Lempel, Edina Pre-Heating Effect on Monomer Elution and Degree of Conversion of Contemporary and Thermoviscous Bulk-Fill Resin-Based Dental Composites |
title | Pre-Heating Effect on Monomer Elution and Degree of Conversion of Contemporary and Thermoviscous Bulk-Fill Resin-Based Dental Composites |
title_full | Pre-Heating Effect on Monomer Elution and Degree of Conversion of Contemporary and Thermoviscous Bulk-Fill Resin-Based Dental Composites |
title_fullStr | Pre-Heating Effect on Monomer Elution and Degree of Conversion of Contemporary and Thermoviscous Bulk-Fill Resin-Based Dental Composites |
title_full_unstemmed | Pre-Heating Effect on Monomer Elution and Degree of Conversion of Contemporary and Thermoviscous Bulk-Fill Resin-Based Dental Composites |
title_short | Pre-Heating Effect on Monomer Elution and Degree of Conversion of Contemporary and Thermoviscous Bulk-Fill Resin-Based Dental Composites |
title_sort | pre-heating effect on monomer elution and degree of conversion of contemporary and thermoviscous bulk-fill resin-based dental composites |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8538921/ https://www.ncbi.nlm.nih.gov/pubmed/34685358 http://dx.doi.org/10.3390/polym13203599 |
work_keys_str_mv | AT kincsesdora preheatingeffectonmonomerelutionanddegreeofconversionofcontemporaryandthermoviscousbulkfillresinbaseddentalcomposites AT boddikatalin preheatingeffectonmonomerelutionanddegreeofconversionofcontemporaryandthermoviscousbulkfillresinbaseddentalcomposites AT orizsuzsanna preheatingeffectonmonomerelutionanddegreeofconversionofcontemporaryandthermoviscousbulkfillresinbaseddentalcomposites AT lovaszbalintviktor preheatingeffectonmonomerelutionanddegreeofconversionofcontemporaryandthermoviscousbulkfillresinbaseddentalcomposites AT jegessara preheatingeffectonmonomerelutionanddegreeofconversionofcontemporaryandthermoviscousbulkfillresinbaseddentalcomposites AT szalmajozsef preheatingeffectonmonomerelutionanddegreeofconversionofcontemporaryandthermoviscousbulkfillresinbaseddentalcomposites AT kunsagimatesandor preheatingeffectonmonomerelutionanddegreeofconversionofcontemporaryandthermoviscousbulkfillresinbaseddentalcomposites AT lempeledina preheatingeffectonmonomerelutionanddegreeofconversionofcontemporaryandthermoviscousbulkfillresinbaseddentalcomposites |