Cargando…

Thermogravimetric Experiment of Urea at Constant Temperatures

There are still many unsolved mysteries in the thermal decomposition process of urea. This paper studied the thermal decomposition process of urea at constant temperatures by the thermal gravimetric–mass spectrometry analysis method. The results show that there are three obvious stages of mass loss...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhu, Neng, Qian, Feng, Xu, Xiaowei, Wang, Mingda, Teng, Qi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8539392/
https://www.ncbi.nlm.nih.gov/pubmed/34683779
http://dx.doi.org/10.3390/ma14206190
_version_ 1784588735946424320
author Zhu, Neng
Qian, Feng
Xu, Xiaowei
Wang, Mingda
Teng, Qi
author_facet Zhu, Neng
Qian, Feng
Xu, Xiaowei
Wang, Mingda
Teng, Qi
author_sort Zhu, Neng
collection PubMed
description There are still many unsolved mysteries in the thermal decomposition process of urea. This paper studied the thermal decomposition process of urea at constant temperatures by the thermal gravimetric–mass spectrometry analysis method. The results show that there are three obvious stages of mass loss during the thermal decomposition process of urea, which is closely related to the temperature. When the temperature was below 160 °C, urea decomposition almost did not occur, and molten urea evaporated slowly. When the temperature was between 180 and 200 °C, the content of biuret, one of the by-products in the thermal decomposition of urea, reached a maximum. When the temperature was higher than 200 °C, the first stage of mass loss was completed quickly, and urea and biuret rapidly broke down. When the temperature was about 240 °C, there were rarely urea and biuret in residual substance; however, the content of cyanuric acid was still rising. When the temperature was higher than 280°C, there was a second stage of mass loss. In the second stage of mass loss, when the temperature was higher than 330 °C, mass decreased rapidly, which was mainly due to the decomposition of cyanuric acid. When the temperature was higher than 380 °C, the third stage of mass loss occurred. However, when the temperature was higher than 400 °C, and after continuous heating was applied for a sufficiently long time, the residual mass was reduced to almost zero eventually.
format Online
Article
Text
id pubmed-8539392
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-85393922021-10-24 Thermogravimetric Experiment of Urea at Constant Temperatures Zhu, Neng Qian, Feng Xu, Xiaowei Wang, Mingda Teng, Qi Materials (Basel) Article There are still many unsolved mysteries in the thermal decomposition process of urea. This paper studied the thermal decomposition process of urea at constant temperatures by the thermal gravimetric–mass spectrometry analysis method. The results show that there are three obvious stages of mass loss during the thermal decomposition process of urea, which is closely related to the temperature. When the temperature was below 160 °C, urea decomposition almost did not occur, and molten urea evaporated slowly. When the temperature was between 180 and 200 °C, the content of biuret, one of the by-products in the thermal decomposition of urea, reached a maximum. When the temperature was higher than 200 °C, the first stage of mass loss was completed quickly, and urea and biuret rapidly broke down. When the temperature was about 240 °C, there were rarely urea and biuret in residual substance; however, the content of cyanuric acid was still rising. When the temperature was higher than 280°C, there was a second stage of mass loss. In the second stage of mass loss, when the temperature was higher than 330 °C, mass decreased rapidly, which was mainly due to the decomposition of cyanuric acid. When the temperature was higher than 380 °C, the third stage of mass loss occurred. However, when the temperature was higher than 400 °C, and after continuous heating was applied for a sufficiently long time, the residual mass was reduced to almost zero eventually. MDPI 2021-10-18 /pmc/articles/PMC8539392/ /pubmed/34683779 http://dx.doi.org/10.3390/ma14206190 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zhu, Neng
Qian, Feng
Xu, Xiaowei
Wang, Mingda
Teng, Qi
Thermogravimetric Experiment of Urea at Constant Temperatures
title Thermogravimetric Experiment of Urea at Constant Temperatures
title_full Thermogravimetric Experiment of Urea at Constant Temperatures
title_fullStr Thermogravimetric Experiment of Urea at Constant Temperatures
title_full_unstemmed Thermogravimetric Experiment of Urea at Constant Temperatures
title_short Thermogravimetric Experiment of Urea at Constant Temperatures
title_sort thermogravimetric experiment of urea at constant temperatures
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8539392/
https://www.ncbi.nlm.nih.gov/pubmed/34683779
http://dx.doi.org/10.3390/ma14206190
work_keys_str_mv AT zhuneng thermogravimetricexperimentofureaatconstanttemperatures
AT qianfeng thermogravimetricexperimentofureaatconstanttemperatures
AT xuxiaowei thermogravimetricexperimentofureaatconstanttemperatures
AT wangmingda thermogravimetricexperimentofureaatconstanttemperatures
AT tengqi thermogravimetricexperimentofureaatconstanttemperatures