Cargando…

Comparison of EI-GC-MS/MS, APCI-LC-MS/MS, and ESI-LC-MS/MS for the Simultaneous Analysis of Nine Nitrosamines Eluted from Synthetic Resins into Artificial Saliva and Health Risk Assessment

Nitrosamines can be produced during the manufacture of rubber-type products such as pacifiers or the nipples of baby bottles. Humans can be exposed to the nitrosamines in these products when they are eluted into saliva. In this study, we compared the efficiency of electron impact ionization (EI), at...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Hyungsoo, Sung, Daekwan, Yu, Honghyeon, Jang, Daeyong, Koo, Yeji, Lee, Seungha, Lim, Kyungmin, Choi, Dalwoong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8540041/
https://www.ncbi.nlm.nih.gov/pubmed/34678926
http://dx.doi.org/10.3390/toxics9100230
_version_ 1784588891746992128
author Kim, Hyungsoo
Sung, Daekwan
Yu, Honghyeon
Jang, Daeyong
Koo, Yeji
Lee, Seungha
Lim, Kyungmin
Choi, Dalwoong
author_facet Kim, Hyungsoo
Sung, Daekwan
Yu, Honghyeon
Jang, Daeyong
Koo, Yeji
Lee, Seungha
Lim, Kyungmin
Choi, Dalwoong
author_sort Kim, Hyungsoo
collection PubMed
description Nitrosamines can be produced during the manufacture of rubber-type products such as pacifiers or the nipples of baby bottles. Humans can be exposed to the nitrosamines in these products when they are eluted into saliva. In this study, we compared the efficiency of electron impact ionization (EI), atmospheric pressure chemical ionization (APCI), and electrospray ionization (ESI) methods for the analysis of nine nitrosamines eluted into artificial saliva. In addition, nine nitrosamines eluted from 54 rubber-type products (rubber, thermoplastic elastomer, thermoplastic polyurethane, and polyurethane) marketed in Korea were monitored. Finally, non-carcinogenic and carcinogenic risk assessments of oral exposure to nine nitrosamines were performed based on the monitoring results. EI-GC-MS/MS performed the best for the simultaneous analysis of these nine nitrosamines with respect to overall linearity, trace analysis limit of detection (less than 1 μg), recovery (average 108.66 ± 9.32%), and precision (less than 6%), compared with liquid chromatography-tandem mass spectrometry (LC-MS/MS) (APCI and ESI) methods. Using the EI-GC-MS/MS method, these nine nitrosamines eluted into artificial saliva from 54 rubber-type products were monitored. Based on the monitoring data, risk assessment was performed by calculating the margin of exposure (MOE) for the respective nitrosamines detected. As a result, these nitrosamines were confirmed to be safe with regard to both non-carcinogenic and carcinogenic risks.
format Online
Article
Text
id pubmed-8540041
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-85400412021-10-24 Comparison of EI-GC-MS/MS, APCI-LC-MS/MS, and ESI-LC-MS/MS for the Simultaneous Analysis of Nine Nitrosamines Eluted from Synthetic Resins into Artificial Saliva and Health Risk Assessment Kim, Hyungsoo Sung, Daekwan Yu, Honghyeon Jang, Daeyong Koo, Yeji Lee, Seungha Lim, Kyungmin Choi, Dalwoong Toxics Article Nitrosamines can be produced during the manufacture of rubber-type products such as pacifiers or the nipples of baby bottles. Humans can be exposed to the nitrosamines in these products when they are eluted into saliva. In this study, we compared the efficiency of electron impact ionization (EI), atmospheric pressure chemical ionization (APCI), and electrospray ionization (ESI) methods for the analysis of nine nitrosamines eluted into artificial saliva. In addition, nine nitrosamines eluted from 54 rubber-type products (rubber, thermoplastic elastomer, thermoplastic polyurethane, and polyurethane) marketed in Korea were monitored. Finally, non-carcinogenic and carcinogenic risk assessments of oral exposure to nine nitrosamines were performed based on the monitoring results. EI-GC-MS/MS performed the best for the simultaneous analysis of these nine nitrosamines with respect to overall linearity, trace analysis limit of detection (less than 1 μg), recovery (average 108.66 ± 9.32%), and precision (less than 6%), compared with liquid chromatography-tandem mass spectrometry (LC-MS/MS) (APCI and ESI) methods. Using the EI-GC-MS/MS method, these nine nitrosamines eluted into artificial saliva from 54 rubber-type products were monitored. Based on the monitoring data, risk assessment was performed by calculating the margin of exposure (MOE) for the respective nitrosamines detected. As a result, these nitrosamines were confirmed to be safe with regard to both non-carcinogenic and carcinogenic risks. MDPI 2021-09-23 /pmc/articles/PMC8540041/ /pubmed/34678926 http://dx.doi.org/10.3390/toxics9100230 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kim, Hyungsoo
Sung, Daekwan
Yu, Honghyeon
Jang, Daeyong
Koo, Yeji
Lee, Seungha
Lim, Kyungmin
Choi, Dalwoong
Comparison of EI-GC-MS/MS, APCI-LC-MS/MS, and ESI-LC-MS/MS for the Simultaneous Analysis of Nine Nitrosamines Eluted from Synthetic Resins into Artificial Saliva and Health Risk Assessment
title Comparison of EI-GC-MS/MS, APCI-LC-MS/MS, and ESI-LC-MS/MS for the Simultaneous Analysis of Nine Nitrosamines Eluted from Synthetic Resins into Artificial Saliva and Health Risk Assessment
title_full Comparison of EI-GC-MS/MS, APCI-LC-MS/MS, and ESI-LC-MS/MS for the Simultaneous Analysis of Nine Nitrosamines Eluted from Synthetic Resins into Artificial Saliva and Health Risk Assessment
title_fullStr Comparison of EI-GC-MS/MS, APCI-LC-MS/MS, and ESI-LC-MS/MS for the Simultaneous Analysis of Nine Nitrosamines Eluted from Synthetic Resins into Artificial Saliva and Health Risk Assessment
title_full_unstemmed Comparison of EI-GC-MS/MS, APCI-LC-MS/MS, and ESI-LC-MS/MS for the Simultaneous Analysis of Nine Nitrosamines Eluted from Synthetic Resins into Artificial Saliva and Health Risk Assessment
title_short Comparison of EI-GC-MS/MS, APCI-LC-MS/MS, and ESI-LC-MS/MS for the Simultaneous Analysis of Nine Nitrosamines Eluted from Synthetic Resins into Artificial Saliva and Health Risk Assessment
title_sort comparison of ei-gc-ms/ms, apci-lc-ms/ms, and esi-lc-ms/ms for the simultaneous analysis of nine nitrosamines eluted from synthetic resins into artificial saliva and health risk assessment
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8540041/
https://www.ncbi.nlm.nih.gov/pubmed/34678926
http://dx.doi.org/10.3390/toxics9100230
work_keys_str_mv AT kimhyungsoo comparisonofeigcmsmsapcilcmsmsandesilcmsmsforthesimultaneousanalysisofninenitrosamineselutedfromsyntheticresinsintoartificialsalivaandhealthriskassessment
AT sungdaekwan comparisonofeigcmsmsapcilcmsmsandesilcmsmsforthesimultaneousanalysisofninenitrosamineselutedfromsyntheticresinsintoartificialsalivaandhealthriskassessment
AT yuhonghyeon comparisonofeigcmsmsapcilcmsmsandesilcmsmsforthesimultaneousanalysisofninenitrosamineselutedfromsyntheticresinsintoartificialsalivaandhealthriskassessment
AT jangdaeyong comparisonofeigcmsmsapcilcmsmsandesilcmsmsforthesimultaneousanalysisofninenitrosamineselutedfromsyntheticresinsintoartificialsalivaandhealthriskassessment
AT kooyeji comparisonofeigcmsmsapcilcmsmsandesilcmsmsforthesimultaneousanalysisofninenitrosamineselutedfromsyntheticresinsintoartificialsalivaandhealthriskassessment
AT leeseungha comparisonofeigcmsmsapcilcmsmsandesilcmsmsforthesimultaneousanalysisofninenitrosamineselutedfromsyntheticresinsintoartificialsalivaandhealthriskassessment
AT limkyungmin comparisonofeigcmsmsapcilcmsmsandesilcmsmsforthesimultaneousanalysisofninenitrosamineselutedfromsyntheticresinsintoartificialsalivaandhealthriskassessment
AT choidalwoong comparisonofeigcmsmsapcilcmsmsandesilcmsmsforthesimultaneousanalysisofninenitrosamineselutedfromsyntheticresinsintoartificialsalivaandhealthriskassessment