Cargando…

In-Line Detection with Microfluidic Bulk Acoustic Wave Resonator Gas Sensor for Gas Chromatography

A microfluidic film bulk acoustic wave resonator gas sensor (mFBAR) adapted specifically as an in-line detector in gas chromatography was described. This miniaturized vapor sensor was a non-destructive detector with very low dead volume (0.02 μL). It was prepared by enclosing the resonator in a micr...

Descripción completa

Detalles Bibliográficos
Autores principales: Hu, Jizhou, Qu, Hemi, Pang, Wei, Duan, Xuexin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8540273/
https://www.ncbi.nlm.nih.gov/pubmed/34696013
http://dx.doi.org/10.3390/s21206800
_version_ 1784588946927255552
author Hu, Jizhou
Qu, Hemi
Pang, Wei
Duan, Xuexin
author_facet Hu, Jizhou
Qu, Hemi
Pang, Wei
Duan, Xuexin
author_sort Hu, Jizhou
collection PubMed
description A microfluidic film bulk acoustic wave resonator gas sensor (mFBAR) adapted specifically as an in-line detector in gas chromatography was described. This miniaturized vapor sensor was a non-destructive detector with very low dead volume (0.02 μL). It was prepared by enclosing the resonator in a microfluidic channel on a chip with dimensions of only 15 mm × 15 mm × 1 mm. The device with polymer coating showed satisfactory performance in the detection of organophosphorus compound, demonstrating a very low detection limit (a dozen parts per billion) with relatively short response time (about fifteen seconds) toward the simulant of chemical warfare agent, dimethyl methylphosphonate. The in-line detection of the mFBAR sensor with FID was constructed and employed to directly measure the concentration profile on the solid surface by the mFBAR with the controlled concentration profile in the mobile phase at the same time. The difference of peak-maximum position between mobile phase and solid phase could be a convenient indicator to measure mass transfer rate. With the response of the mFBAR and FID obtained in one injection, an injection mass-independent parameter can be calculated and used to identify the analyte of interest.
format Online
Article
Text
id pubmed-8540273
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-85402732021-10-24 In-Line Detection with Microfluidic Bulk Acoustic Wave Resonator Gas Sensor for Gas Chromatography Hu, Jizhou Qu, Hemi Pang, Wei Duan, Xuexin Sensors (Basel) Article A microfluidic film bulk acoustic wave resonator gas sensor (mFBAR) adapted specifically as an in-line detector in gas chromatography was described. This miniaturized vapor sensor was a non-destructive detector with very low dead volume (0.02 μL). It was prepared by enclosing the resonator in a microfluidic channel on a chip with dimensions of only 15 mm × 15 mm × 1 mm. The device with polymer coating showed satisfactory performance in the detection of organophosphorus compound, demonstrating a very low detection limit (a dozen parts per billion) with relatively short response time (about fifteen seconds) toward the simulant of chemical warfare agent, dimethyl methylphosphonate. The in-line detection of the mFBAR sensor with FID was constructed and employed to directly measure the concentration profile on the solid surface by the mFBAR with the controlled concentration profile in the mobile phase at the same time. The difference of peak-maximum position between mobile phase and solid phase could be a convenient indicator to measure mass transfer rate. With the response of the mFBAR and FID obtained in one injection, an injection mass-independent parameter can be calculated and used to identify the analyte of interest. MDPI 2021-10-13 /pmc/articles/PMC8540273/ /pubmed/34696013 http://dx.doi.org/10.3390/s21206800 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Hu, Jizhou
Qu, Hemi
Pang, Wei
Duan, Xuexin
In-Line Detection with Microfluidic Bulk Acoustic Wave Resonator Gas Sensor for Gas Chromatography
title In-Line Detection with Microfluidic Bulk Acoustic Wave Resonator Gas Sensor for Gas Chromatography
title_full In-Line Detection with Microfluidic Bulk Acoustic Wave Resonator Gas Sensor for Gas Chromatography
title_fullStr In-Line Detection with Microfluidic Bulk Acoustic Wave Resonator Gas Sensor for Gas Chromatography
title_full_unstemmed In-Line Detection with Microfluidic Bulk Acoustic Wave Resonator Gas Sensor for Gas Chromatography
title_short In-Line Detection with Microfluidic Bulk Acoustic Wave Resonator Gas Sensor for Gas Chromatography
title_sort in-line detection with microfluidic bulk acoustic wave resonator gas sensor for gas chromatography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8540273/
https://www.ncbi.nlm.nih.gov/pubmed/34696013
http://dx.doi.org/10.3390/s21206800
work_keys_str_mv AT hujizhou inlinedetectionwithmicrofluidicbulkacousticwaveresonatorgassensorforgaschromatography
AT quhemi inlinedetectionwithmicrofluidicbulkacousticwaveresonatorgassensorforgaschromatography
AT pangwei inlinedetectionwithmicrofluidicbulkacousticwaveresonatorgassensorforgaschromatography
AT duanxuexin inlinedetectionwithmicrofluidicbulkacousticwaveresonatorgassensorforgaschromatography