Cargando…
An Automated Hydrodynamically Mediated Technique for Preparation of Calibration Solutions via Capillary Electrophoresis System as a Promising Alternative to Manual Pipetting
In this paper, a novel procedure for preparing calibration solutions for capillary electrophoresis (CE)-based quantitative analysis is proposed. Our approach, named the automated hydrodynamically mediated technique (AHMT), uses a capillary and a pressure system to deliver the expected amount of work...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8540481/ https://www.ncbi.nlm.nih.gov/pubmed/34684849 http://dx.doi.org/10.3390/molecules26206268 |
_version_ | 1784588997345935360 |
---|---|
author | Gołąb, Małgorzata Woźniakiewicz, Michał Nowak, Paweł M. Kościelniak, Paweł |
author_facet | Gołąb, Małgorzata Woźniakiewicz, Michał Nowak, Paweł M. Kościelniak, Paweł |
author_sort | Gołąb, Małgorzata |
collection | PubMed |
description | In this paper, a novel procedure for preparing calibration solutions for capillary electrophoresis (CE)-based quantitative analysis is proposed. Our approach, named the automated hydrodynamically mediated technique (AHMT), uses a capillary and a pressure system to deliver the expected amount of working solution and diluent directly to a sample vial. As a result, calibration solutions are prepared automatically inside the CE instrument, without any or with minimal manual operation. Two different modes were tested: forward and reverse, differing in the direction of hydrodynamic flow. The calibration curves obtained for a model mixture of analytes using AHMT were thorough compared to the standard procedure based on manual pipetting. The results were consistent, though the volume of obtained calibration solutions and the potential risk of random errors were significantly minimized by AHMT. Its effectiveness was further enhanced by the application of SCIEX(®) nanoVials, reducing the actual volume of calibration solutions down to 10 μL. |
format | Online Article Text |
id | pubmed-8540481 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-85404812021-10-24 An Automated Hydrodynamically Mediated Technique for Preparation of Calibration Solutions via Capillary Electrophoresis System as a Promising Alternative to Manual Pipetting Gołąb, Małgorzata Woźniakiewicz, Michał Nowak, Paweł M. Kościelniak, Paweł Molecules Article In this paper, a novel procedure for preparing calibration solutions for capillary electrophoresis (CE)-based quantitative analysis is proposed. Our approach, named the automated hydrodynamically mediated technique (AHMT), uses a capillary and a pressure system to deliver the expected amount of working solution and diluent directly to a sample vial. As a result, calibration solutions are prepared automatically inside the CE instrument, without any or with minimal manual operation. Two different modes were tested: forward and reverse, differing in the direction of hydrodynamic flow. The calibration curves obtained for a model mixture of analytes using AHMT were thorough compared to the standard procedure based on manual pipetting. The results were consistent, though the volume of obtained calibration solutions and the potential risk of random errors were significantly minimized by AHMT. Its effectiveness was further enhanced by the application of SCIEX(®) nanoVials, reducing the actual volume of calibration solutions down to 10 μL. MDPI 2021-10-16 /pmc/articles/PMC8540481/ /pubmed/34684849 http://dx.doi.org/10.3390/molecules26206268 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Gołąb, Małgorzata Woźniakiewicz, Michał Nowak, Paweł M. Kościelniak, Paweł An Automated Hydrodynamically Mediated Technique for Preparation of Calibration Solutions via Capillary Electrophoresis System as a Promising Alternative to Manual Pipetting |
title | An Automated Hydrodynamically Mediated Technique for Preparation of Calibration Solutions via Capillary Electrophoresis System as a Promising Alternative to Manual Pipetting |
title_full | An Automated Hydrodynamically Mediated Technique for Preparation of Calibration Solutions via Capillary Electrophoresis System as a Promising Alternative to Manual Pipetting |
title_fullStr | An Automated Hydrodynamically Mediated Technique for Preparation of Calibration Solutions via Capillary Electrophoresis System as a Promising Alternative to Manual Pipetting |
title_full_unstemmed | An Automated Hydrodynamically Mediated Technique for Preparation of Calibration Solutions via Capillary Electrophoresis System as a Promising Alternative to Manual Pipetting |
title_short | An Automated Hydrodynamically Mediated Technique for Preparation of Calibration Solutions via Capillary Electrophoresis System as a Promising Alternative to Manual Pipetting |
title_sort | automated hydrodynamically mediated technique for preparation of calibration solutions via capillary electrophoresis system as a promising alternative to manual pipetting |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8540481/ https://www.ncbi.nlm.nih.gov/pubmed/34684849 http://dx.doi.org/10.3390/molecules26206268 |
work_keys_str_mv | AT gołabmałgorzata anautomatedhydrodynamicallymediatedtechniqueforpreparationofcalibrationsolutionsviacapillaryelectrophoresissystemasapromisingalternativetomanualpipetting AT wozniakiewiczmichał anautomatedhydrodynamicallymediatedtechniqueforpreparationofcalibrationsolutionsviacapillaryelectrophoresissystemasapromisingalternativetomanualpipetting AT nowakpawełm anautomatedhydrodynamicallymediatedtechniqueforpreparationofcalibrationsolutionsviacapillaryelectrophoresissystemasapromisingalternativetomanualpipetting AT koscielniakpaweł anautomatedhydrodynamicallymediatedtechniqueforpreparationofcalibrationsolutionsviacapillaryelectrophoresissystemasapromisingalternativetomanualpipetting AT gołabmałgorzata automatedhydrodynamicallymediatedtechniqueforpreparationofcalibrationsolutionsviacapillaryelectrophoresissystemasapromisingalternativetomanualpipetting AT wozniakiewiczmichał automatedhydrodynamicallymediatedtechniqueforpreparationofcalibrationsolutionsviacapillaryelectrophoresissystemasapromisingalternativetomanualpipetting AT nowakpawełm automatedhydrodynamicallymediatedtechniqueforpreparationofcalibrationsolutionsviacapillaryelectrophoresissystemasapromisingalternativetomanualpipetting AT koscielniakpaweł automatedhydrodynamicallymediatedtechniqueforpreparationofcalibrationsolutionsviacapillaryelectrophoresissystemasapromisingalternativetomanualpipetting |