Cargando…

Evaluation of Surface Change and Roughness in Implants Lost Due to Peri-Implantitis Using Erbium Laser and Various Methods: An In Vitro Study

The aim of our study was to obtain similar surface properties and elemental composition to virgin implants after debridement of contaminated titanium implant surfaces covered with debris. Erbium-doped:yttrium, aluminum, and garnet (Er:YAG) laser, erbium, chromium-doped:yttrium, scandium, gallium, an...

Descripción completa

Detalles Bibliográficos
Autores principales: Secgin-Atar, Aslihan, Aykol-Sahin, Gokce, Kocak-Oztug, Necla Asli, Yalcin, Funda, Gokbuget, Aslan, Baser, Ulku
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8540706/
https://www.ncbi.nlm.nih.gov/pubmed/34685043
http://dx.doi.org/10.3390/nano11102602
_version_ 1784589051975696384
author Secgin-Atar, Aslihan
Aykol-Sahin, Gokce
Kocak-Oztug, Necla Asli
Yalcin, Funda
Gokbuget, Aslan
Baser, Ulku
author_facet Secgin-Atar, Aslihan
Aykol-Sahin, Gokce
Kocak-Oztug, Necla Asli
Yalcin, Funda
Gokbuget, Aslan
Baser, Ulku
author_sort Secgin-Atar, Aslihan
collection PubMed
description The aim of our study was to obtain similar surface properties and elemental composition to virgin implants after debridement of contaminated titanium implant surfaces covered with debris. Erbium-doped:yttrium, aluminum, and garnet (Er:YAG) laser, erbium, chromium-doped:yttrium, scandium, gallium, and garnet (Er,Cr:YSGG) laser, curette, and ultrasonic device were applied to contaminated implant surfaces. Scanning electron microscopy (SEM) images were taken, the elemental profile of the surfaces was evaluated with energy dispersive X-ray spectroscopy (EDX), and the surface roughness was analyzed with profilometry. Twenty-eight failed implants and two virgin implants as control were included in the study. The groups were designed accordingly; titanium curette group, ultrasonic scaler with polyetheretherketone (PEEK) tip, Er: YAG very short pulse laser group (100 μs, 120 mJ/pulse 10 Hz), Er: YAG short-pulse laser group (300 μs, 120 mJ/pulse, 10 Hz), Er: YAG long-pulse laser group (600 μs, 120 mJ/pulse, 10 Hz), Er, Cr: YSGG1 laser group (1 W 10 Hz), Er, Cr: YSGG2 laser group (1.5 W, 30 Hz). In each group, four failed implants were debrided for 120 s. When SEM images and EDX findings and profilometry results were evaluated together, Er: YAG long pulse and ultrasonic groups were found to be the most effective for debridement. Furthermore, the two interventions have shown the closest topography of the sandblasted, large grit, acid-etched implant surface (SLA) as seen on virgin implants.
format Online
Article
Text
id pubmed-8540706
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-85407062021-10-24 Evaluation of Surface Change and Roughness in Implants Lost Due to Peri-Implantitis Using Erbium Laser and Various Methods: An In Vitro Study Secgin-Atar, Aslihan Aykol-Sahin, Gokce Kocak-Oztug, Necla Asli Yalcin, Funda Gokbuget, Aslan Baser, Ulku Nanomaterials (Basel) Article The aim of our study was to obtain similar surface properties and elemental composition to virgin implants after debridement of contaminated titanium implant surfaces covered with debris. Erbium-doped:yttrium, aluminum, and garnet (Er:YAG) laser, erbium, chromium-doped:yttrium, scandium, gallium, and garnet (Er,Cr:YSGG) laser, curette, and ultrasonic device were applied to contaminated implant surfaces. Scanning electron microscopy (SEM) images were taken, the elemental profile of the surfaces was evaluated with energy dispersive X-ray spectroscopy (EDX), and the surface roughness was analyzed with profilometry. Twenty-eight failed implants and two virgin implants as control were included in the study. The groups were designed accordingly; titanium curette group, ultrasonic scaler with polyetheretherketone (PEEK) tip, Er: YAG very short pulse laser group (100 μs, 120 mJ/pulse 10 Hz), Er: YAG short-pulse laser group (300 μs, 120 mJ/pulse, 10 Hz), Er: YAG long-pulse laser group (600 μs, 120 mJ/pulse, 10 Hz), Er, Cr: YSGG1 laser group (1 W 10 Hz), Er, Cr: YSGG2 laser group (1.5 W, 30 Hz). In each group, four failed implants were debrided for 120 s. When SEM images and EDX findings and profilometry results were evaluated together, Er: YAG long pulse and ultrasonic groups were found to be the most effective for debridement. Furthermore, the two interventions have shown the closest topography of the sandblasted, large grit, acid-etched implant surface (SLA) as seen on virgin implants. MDPI 2021-10-02 /pmc/articles/PMC8540706/ /pubmed/34685043 http://dx.doi.org/10.3390/nano11102602 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Secgin-Atar, Aslihan
Aykol-Sahin, Gokce
Kocak-Oztug, Necla Asli
Yalcin, Funda
Gokbuget, Aslan
Baser, Ulku
Evaluation of Surface Change and Roughness in Implants Lost Due to Peri-Implantitis Using Erbium Laser and Various Methods: An In Vitro Study
title Evaluation of Surface Change and Roughness in Implants Lost Due to Peri-Implantitis Using Erbium Laser and Various Methods: An In Vitro Study
title_full Evaluation of Surface Change and Roughness in Implants Lost Due to Peri-Implantitis Using Erbium Laser and Various Methods: An In Vitro Study
title_fullStr Evaluation of Surface Change and Roughness in Implants Lost Due to Peri-Implantitis Using Erbium Laser and Various Methods: An In Vitro Study
title_full_unstemmed Evaluation of Surface Change and Roughness in Implants Lost Due to Peri-Implantitis Using Erbium Laser and Various Methods: An In Vitro Study
title_short Evaluation of Surface Change and Roughness in Implants Lost Due to Peri-Implantitis Using Erbium Laser and Various Methods: An In Vitro Study
title_sort evaluation of surface change and roughness in implants lost due to peri-implantitis using erbium laser and various methods: an in vitro study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8540706/
https://www.ncbi.nlm.nih.gov/pubmed/34685043
http://dx.doi.org/10.3390/nano11102602
work_keys_str_mv AT secginataraslihan evaluationofsurfacechangeandroughnessinimplantslostduetoperiimplantitisusingerbiumlaserandvariousmethodsaninvitrostudy
AT aykolsahingokce evaluationofsurfacechangeandroughnessinimplantslostduetoperiimplantitisusingerbiumlaserandvariousmethodsaninvitrostudy
AT kocakoztugneclaasli evaluationofsurfacechangeandroughnessinimplantslostduetoperiimplantitisusingerbiumlaserandvariousmethodsaninvitrostudy
AT yalcinfunda evaluationofsurfacechangeandroughnessinimplantslostduetoperiimplantitisusingerbiumlaserandvariousmethodsaninvitrostudy
AT gokbugetaslan evaluationofsurfacechangeandroughnessinimplantslostduetoperiimplantitisusingerbiumlaserandvariousmethodsaninvitrostudy
AT baserulku evaluationofsurfacechangeandroughnessinimplantslostduetoperiimplantitisusingerbiumlaserandvariousmethodsaninvitrostudy