Cargando…

Simultaneous Droplet Generation with In-Series Droplet T-Junctions Induced by Gravity-Induced Flow

Droplet microfluidics offers a wide range of applications, including high-throughput drug screening and single-cell DNA amplification. However, these platforms are often limited to single-input conditions that prevent them from analyzing multiple input parameters (e.g., combined cellular treatments)...

Descripción completa

Detalles Bibliográficos
Autores principales: Bajgiran, Khashayar R., Cordova, Alejandro S., Elkhanoufi, Riad, Dorman, James A., Melvin, Adam T.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8540845/
https://www.ncbi.nlm.nih.gov/pubmed/34683262
http://dx.doi.org/10.3390/mi12101211
_version_ 1784589085142155264
author Bajgiran, Khashayar R.
Cordova, Alejandro S.
Elkhanoufi, Riad
Dorman, James A.
Melvin, Adam T.
author_facet Bajgiran, Khashayar R.
Cordova, Alejandro S.
Elkhanoufi, Riad
Dorman, James A.
Melvin, Adam T.
author_sort Bajgiran, Khashayar R.
collection PubMed
description Droplet microfluidics offers a wide range of applications, including high-throughput drug screening and single-cell DNA amplification. However, these platforms are often limited to single-input conditions that prevent them from analyzing multiple input parameters (e.g., combined cellular treatments) in a single experiment. Droplet multiplexing will result in higher overall throughput, lowering cost of fabrication, and cutting down the hands-on time in number of applications such as single-cell analysis. Additionally, while lab-on-a-chip fabrication costs have decreased in recent years, the syringe pumps required for generating droplets of uniform shape and size remain cost-prohibitive for researchers interested in utilizing droplet microfluidics. This work investigates the potential of simultaneously generating droplets from a series of three in-line T-junctions utilizing gravity-driven flow to produce consistent, well-defined droplets. Implementing reservoirs with equal heights produced inconsistent flow rates that increased as a function of the distance between the aqueous inlets and the oil inlet. Optimizing the three reservoir heights identified that taller reservoirs were needed for aqueous inlets closer to the oil inlet. Studying the relationship between the ratio of oil-to-water flow rates (Φ) found that increasing Φ resulted in smaller droplets and an enhanced droplet generation rate. An ANOVA was performed on droplet diameter to confirm no significant difference in droplet size from the three different aqueous inlets. The work described here offers an alternative approach to multiplexed droplet microfluidic devices allowing for the high-throughput interrogation of three sample conditions in a single device. It also has provided an alternative method to induce droplet formation that does not require multiple syringe pumps.
format Online
Article
Text
id pubmed-8540845
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-85408452021-10-24 Simultaneous Droplet Generation with In-Series Droplet T-Junctions Induced by Gravity-Induced Flow Bajgiran, Khashayar R. Cordova, Alejandro S. Elkhanoufi, Riad Dorman, James A. Melvin, Adam T. Micromachines (Basel) Article Droplet microfluidics offers a wide range of applications, including high-throughput drug screening and single-cell DNA amplification. However, these platforms are often limited to single-input conditions that prevent them from analyzing multiple input parameters (e.g., combined cellular treatments) in a single experiment. Droplet multiplexing will result in higher overall throughput, lowering cost of fabrication, and cutting down the hands-on time in number of applications such as single-cell analysis. Additionally, while lab-on-a-chip fabrication costs have decreased in recent years, the syringe pumps required for generating droplets of uniform shape and size remain cost-prohibitive for researchers interested in utilizing droplet microfluidics. This work investigates the potential of simultaneously generating droplets from a series of three in-line T-junctions utilizing gravity-driven flow to produce consistent, well-defined droplets. Implementing reservoirs with equal heights produced inconsistent flow rates that increased as a function of the distance between the aqueous inlets and the oil inlet. Optimizing the three reservoir heights identified that taller reservoirs were needed for aqueous inlets closer to the oil inlet. Studying the relationship between the ratio of oil-to-water flow rates (Φ) found that increasing Φ resulted in smaller droplets and an enhanced droplet generation rate. An ANOVA was performed on droplet diameter to confirm no significant difference in droplet size from the three different aqueous inlets. The work described here offers an alternative approach to multiplexed droplet microfluidic devices allowing for the high-throughput interrogation of three sample conditions in a single device. It also has provided an alternative method to induce droplet formation that does not require multiple syringe pumps. MDPI 2021-10-04 /pmc/articles/PMC8540845/ /pubmed/34683262 http://dx.doi.org/10.3390/mi12101211 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Bajgiran, Khashayar R.
Cordova, Alejandro S.
Elkhanoufi, Riad
Dorman, James A.
Melvin, Adam T.
Simultaneous Droplet Generation with In-Series Droplet T-Junctions Induced by Gravity-Induced Flow
title Simultaneous Droplet Generation with In-Series Droplet T-Junctions Induced by Gravity-Induced Flow
title_full Simultaneous Droplet Generation with In-Series Droplet T-Junctions Induced by Gravity-Induced Flow
title_fullStr Simultaneous Droplet Generation with In-Series Droplet T-Junctions Induced by Gravity-Induced Flow
title_full_unstemmed Simultaneous Droplet Generation with In-Series Droplet T-Junctions Induced by Gravity-Induced Flow
title_short Simultaneous Droplet Generation with In-Series Droplet T-Junctions Induced by Gravity-Induced Flow
title_sort simultaneous droplet generation with in-series droplet t-junctions induced by gravity-induced flow
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8540845/
https://www.ncbi.nlm.nih.gov/pubmed/34683262
http://dx.doi.org/10.3390/mi12101211
work_keys_str_mv AT bajgirankhashayarr simultaneousdropletgenerationwithinseriesdroplettjunctionsinducedbygravityinducedflow
AT cordovaalejandros simultaneousdropletgenerationwithinseriesdroplettjunctionsinducedbygravityinducedflow
AT elkhanoufiriad simultaneousdropletgenerationwithinseriesdroplettjunctionsinducedbygravityinducedflow
AT dormanjamesa simultaneousdropletgenerationwithinseriesdroplettjunctionsinducedbygravityinducedflow
AT melvinadamt simultaneousdropletgenerationwithinseriesdroplettjunctionsinducedbygravityinducedflow