Cargando…
Dynamic Electrocardiogram under P Wave Detection Algorithm Combined with Low-Dose Betaloc in Diagnosis and Treatment of Patients with Arrhythmia after Hepatocarcinoma Resection
This work aimed to study the diagnostic value of dynamic electrocardiogram (ECG) based on P wave detection algorithm for arrhythmia after hepatectomy in patients with primary liver cancer, and to compare the therapeutic effect of different doses of Betaloc. P wave detection algorithm was introduced...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8541856/ https://www.ncbi.nlm.nih.gov/pubmed/34697566 http://dx.doi.org/10.1155/2021/6034180 |
_version_ | 1784589331129696256 |
---|---|
author | Jiang, Fenfen Xu, Haokai Shi, Xiaowen Han, Bingjiang Chu, Zhenliang Xu, Bin Liu, Xiaorong |
author_facet | Jiang, Fenfen Xu, Haokai Shi, Xiaowen Han, Bingjiang Chu, Zhenliang Xu, Bin Liu, Xiaorong |
author_sort | Jiang, Fenfen |
collection | PubMed |
description | This work aimed to study the diagnostic value of dynamic electrocardiogram (ECG) based on P wave detection algorithm for arrhythmia after hepatectomy in patients with primary liver cancer, and to compare the therapeutic effect of different doses of Betaloc. P wave detection algorithm was introduced for ECG automatic detection and analysis, which can be used for early diagnosis of arrhythmia. Sixty patients with arrhythmia after hepatectomy for primary liver cancer were selected as the research objects. They were randomly divided into control group, SD group, MD group, and HD group, with 15 cases in each group. No Betaloc, low-dose (≤47.5 mg), medium-dose (47.5–95 mg), and high-dose (142.5–190 mg) Betaloc were used for treatment. As a result, P wave detection algorithms can mark P waves that may be submerged in strong interference. P waves from arrhythmia database were used to verify the performance of the proposed algorithm. The prediction precision (Pp) of ventricular arrhythmia and atrial arrhythmia was 98.53% and 98.76%, respectively. Systolic blood pressure (117.35 ± 7.33, 126.44 ± 9.38, and 116.02 ± 8.2) mmHg in SD group, MD group, and HD group was significantly lower than that in control group (140.3 ± 7.21) mmHg after two weeks of treatment. Moreover, those of SD group and HD group were significantly lower than MD group (P < 0.05). The effective rate of cardiac function improvement in SD group (72.35 ± 1.21%) was significantly higher than that in control group, MD group, and HD group (38.2 ± 0.98%, 65.12 ± 1.33%, and 60.43 ± 1.25%; P < 0.05). In short, dynamic ECG based on P wave detection algorithm had high diagnostic value for arrhythmia after hepatectomy in patients with primary liver cancer. It was safe and effective for patients to choose small dose of Betaloc. |
format | Online Article Text |
id | pubmed-8541856 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-85418562021-10-24 Dynamic Electrocardiogram under P Wave Detection Algorithm Combined with Low-Dose Betaloc in Diagnosis and Treatment of Patients with Arrhythmia after Hepatocarcinoma Resection Jiang, Fenfen Xu, Haokai Shi, Xiaowen Han, Bingjiang Chu, Zhenliang Xu, Bin Liu, Xiaorong J Healthc Eng Research Article This work aimed to study the diagnostic value of dynamic electrocardiogram (ECG) based on P wave detection algorithm for arrhythmia after hepatectomy in patients with primary liver cancer, and to compare the therapeutic effect of different doses of Betaloc. P wave detection algorithm was introduced for ECG automatic detection and analysis, which can be used for early diagnosis of arrhythmia. Sixty patients with arrhythmia after hepatectomy for primary liver cancer were selected as the research objects. They were randomly divided into control group, SD group, MD group, and HD group, with 15 cases in each group. No Betaloc, low-dose (≤47.5 mg), medium-dose (47.5–95 mg), and high-dose (142.5–190 mg) Betaloc were used for treatment. As a result, P wave detection algorithms can mark P waves that may be submerged in strong interference. P waves from arrhythmia database were used to verify the performance of the proposed algorithm. The prediction precision (Pp) of ventricular arrhythmia and atrial arrhythmia was 98.53% and 98.76%, respectively. Systolic blood pressure (117.35 ± 7.33, 126.44 ± 9.38, and 116.02 ± 8.2) mmHg in SD group, MD group, and HD group was significantly lower than that in control group (140.3 ± 7.21) mmHg after two weeks of treatment. Moreover, those of SD group and HD group were significantly lower than MD group (P < 0.05). The effective rate of cardiac function improvement in SD group (72.35 ± 1.21%) was significantly higher than that in control group, MD group, and HD group (38.2 ± 0.98%, 65.12 ± 1.33%, and 60.43 ± 1.25%; P < 0.05). In short, dynamic ECG based on P wave detection algorithm had high diagnostic value for arrhythmia after hepatectomy in patients with primary liver cancer. It was safe and effective for patients to choose small dose of Betaloc. Hindawi 2021-10-16 /pmc/articles/PMC8541856/ /pubmed/34697566 http://dx.doi.org/10.1155/2021/6034180 Text en Copyright © 2021 Fenfen Jiang et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Jiang, Fenfen Xu, Haokai Shi, Xiaowen Han, Bingjiang Chu, Zhenliang Xu, Bin Liu, Xiaorong Dynamic Electrocardiogram under P Wave Detection Algorithm Combined with Low-Dose Betaloc in Diagnosis and Treatment of Patients with Arrhythmia after Hepatocarcinoma Resection |
title | Dynamic Electrocardiogram under P Wave Detection Algorithm Combined with Low-Dose Betaloc in Diagnosis and Treatment of Patients with Arrhythmia after Hepatocarcinoma Resection |
title_full | Dynamic Electrocardiogram under P Wave Detection Algorithm Combined with Low-Dose Betaloc in Diagnosis and Treatment of Patients with Arrhythmia after Hepatocarcinoma Resection |
title_fullStr | Dynamic Electrocardiogram under P Wave Detection Algorithm Combined with Low-Dose Betaloc in Diagnosis and Treatment of Patients with Arrhythmia after Hepatocarcinoma Resection |
title_full_unstemmed | Dynamic Electrocardiogram under P Wave Detection Algorithm Combined with Low-Dose Betaloc in Diagnosis and Treatment of Patients with Arrhythmia after Hepatocarcinoma Resection |
title_short | Dynamic Electrocardiogram under P Wave Detection Algorithm Combined with Low-Dose Betaloc in Diagnosis and Treatment of Patients with Arrhythmia after Hepatocarcinoma Resection |
title_sort | dynamic electrocardiogram under p wave detection algorithm combined with low-dose betaloc in diagnosis and treatment of patients with arrhythmia after hepatocarcinoma resection |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8541856/ https://www.ncbi.nlm.nih.gov/pubmed/34697566 http://dx.doi.org/10.1155/2021/6034180 |
work_keys_str_mv | AT jiangfenfen dynamicelectrocardiogramunderpwavedetectionalgorithmcombinedwithlowdosebetalocindiagnosisandtreatmentofpatientswitharrhythmiaafterhepatocarcinomaresection AT xuhaokai dynamicelectrocardiogramunderpwavedetectionalgorithmcombinedwithlowdosebetalocindiagnosisandtreatmentofpatientswitharrhythmiaafterhepatocarcinomaresection AT shixiaowen dynamicelectrocardiogramunderpwavedetectionalgorithmcombinedwithlowdosebetalocindiagnosisandtreatmentofpatientswitharrhythmiaafterhepatocarcinomaresection AT hanbingjiang dynamicelectrocardiogramunderpwavedetectionalgorithmcombinedwithlowdosebetalocindiagnosisandtreatmentofpatientswitharrhythmiaafterhepatocarcinomaresection AT chuzhenliang dynamicelectrocardiogramunderpwavedetectionalgorithmcombinedwithlowdosebetalocindiagnosisandtreatmentofpatientswitharrhythmiaafterhepatocarcinomaresection AT xubin dynamicelectrocardiogramunderpwavedetectionalgorithmcombinedwithlowdosebetalocindiagnosisandtreatmentofpatientswitharrhythmiaafterhepatocarcinomaresection AT liuxiaorong dynamicelectrocardiogramunderpwavedetectionalgorithmcombinedwithlowdosebetalocindiagnosisandtreatmentofpatientswitharrhythmiaafterhepatocarcinomaresection |