Dynamic assessment of variations in pupil diameter using swept-source anterior segment optical coherence tomography after phakic collamer lens implantation
PURPOSE: To dynamically assess variations in pupil diameter induced by changes in brightness in myopic eyes implanted with an implantable collamer lens (ICL, STAAR Surgical) with a central port. METHODS: This prospective, observational single-center case series study comprised 65 eyes from 65 consec...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8542318/ https://www.ncbi.nlm.nih.gov/pubmed/34688308 http://dx.doi.org/10.1186/s40662-021-00262-2 |
_version_ | 1784589405742170112 |
---|---|
author | Gonzalez-Lopez, Felix Bouza-Miguens, Carmen Tejerina, Victor Druchkiv, Vasyl Mompean, Blas Ortega-Usobiaga, Julio Bilbao-Calabuig, Rafael |
author_facet | Gonzalez-Lopez, Felix Bouza-Miguens, Carmen Tejerina, Victor Druchkiv, Vasyl Mompean, Blas Ortega-Usobiaga, Julio Bilbao-Calabuig, Rafael |
author_sort | Gonzalez-Lopez, Felix |
collection | PubMed |
description | PURPOSE: To dynamically assess variations in pupil diameter induced by changes in brightness in myopic eyes implanted with an implantable collamer lens (ICL, STAAR Surgical) with a central port. METHODS: This prospective, observational single-center case series study comprised 65 eyes from 65 consecutive patients undergoing ICL implant. A modified commercially available swept-source Fourier-domain anterior segment optical coherence tomography (AS-OCT) device was used for imaging and performing dynamic pupillometry under changing light conditions before and after a mean follow-up interval of four months after surgery. RESULTS: Preoperative mean pupil size under photopic conditions was 3.38 ± 0.64 mm; after surgery, this increased to 3.48 ± 0.61 mm. Mean pupil size under scotopic light conditions was 5.72 ± 0.79 mm before surgery and 5.84 ± 0.77 mm postoperatively. The differences between preoperative and postoperative pupil diameter in miosis and mydriasis were 0.10 ± 0.44 mm (P = 0.078) and 0.12 ± 0.58 mm (P = 0.098), respectively. The scotopic pupil exceeded the optic zone of the implanted lens in 39 eyes (60%). The mean central vault value was 412 ± 177 μm under maximum miosis and 506 ± 190 μm under maximum mydriasis. We found a positive correlation between vault and differences in pupil diameter under all light conditions (P < 0.05). CONCLUSION: Dynamic AS-OCT enables a very precise determination of the pupillary diameter in the iris plane. The changes in the pupil diameter under different light conditions after the implantation of an ICL are related to the postoperative vault. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s40662-021-00262-2. |
format | Online Article Text |
id | pubmed-8542318 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-85423182021-10-25 Dynamic assessment of variations in pupil diameter using swept-source anterior segment optical coherence tomography after phakic collamer lens implantation Gonzalez-Lopez, Felix Bouza-Miguens, Carmen Tejerina, Victor Druchkiv, Vasyl Mompean, Blas Ortega-Usobiaga, Julio Bilbao-Calabuig, Rafael Eye Vis (Lond) Research PURPOSE: To dynamically assess variations in pupil diameter induced by changes in brightness in myopic eyes implanted with an implantable collamer lens (ICL, STAAR Surgical) with a central port. METHODS: This prospective, observational single-center case series study comprised 65 eyes from 65 consecutive patients undergoing ICL implant. A modified commercially available swept-source Fourier-domain anterior segment optical coherence tomography (AS-OCT) device was used for imaging and performing dynamic pupillometry under changing light conditions before and after a mean follow-up interval of four months after surgery. RESULTS: Preoperative mean pupil size under photopic conditions was 3.38 ± 0.64 mm; after surgery, this increased to 3.48 ± 0.61 mm. Mean pupil size under scotopic light conditions was 5.72 ± 0.79 mm before surgery and 5.84 ± 0.77 mm postoperatively. The differences between preoperative and postoperative pupil diameter in miosis and mydriasis were 0.10 ± 0.44 mm (P = 0.078) and 0.12 ± 0.58 mm (P = 0.098), respectively. The scotopic pupil exceeded the optic zone of the implanted lens in 39 eyes (60%). The mean central vault value was 412 ± 177 μm under maximum miosis and 506 ± 190 μm under maximum mydriasis. We found a positive correlation between vault and differences in pupil diameter under all light conditions (P < 0.05). CONCLUSION: Dynamic AS-OCT enables a very precise determination of the pupillary diameter in the iris plane. The changes in the pupil diameter under different light conditions after the implantation of an ICL are related to the postoperative vault. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s40662-021-00262-2. BioMed Central 2021-10-24 /pmc/articles/PMC8542318/ /pubmed/34688308 http://dx.doi.org/10.1186/s40662-021-00262-2 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Gonzalez-Lopez, Felix Bouza-Miguens, Carmen Tejerina, Victor Druchkiv, Vasyl Mompean, Blas Ortega-Usobiaga, Julio Bilbao-Calabuig, Rafael Dynamic assessment of variations in pupil diameter using swept-source anterior segment optical coherence tomography after phakic collamer lens implantation |
title | Dynamic assessment of variations in pupil diameter using swept-source anterior segment optical coherence tomography after phakic collamer lens implantation |
title_full | Dynamic assessment of variations in pupil diameter using swept-source anterior segment optical coherence tomography after phakic collamer lens implantation |
title_fullStr | Dynamic assessment of variations in pupil diameter using swept-source anterior segment optical coherence tomography after phakic collamer lens implantation |
title_full_unstemmed | Dynamic assessment of variations in pupil diameter using swept-source anterior segment optical coherence tomography after phakic collamer lens implantation |
title_short | Dynamic assessment of variations in pupil diameter using swept-source anterior segment optical coherence tomography after phakic collamer lens implantation |
title_sort | dynamic assessment of variations in pupil diameter using swept-source anterior segment optical coherence tomography after phakic collamer lens implantation |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8542318/ https://www.ncbi.nlm.nih.gov/pubmed/34688308 http://dx.doi.org/10.1186/s40662-021-00262-2 |
work_keys_str_mv | AT gonzalezlopezfelix dynamicassessmentofvariationsinpupildiameterusingsweptsourceanteriorsegmentopticalcoherencetomographyafterphakiccollamerlensimplantation AT bouzamiguenscarmen dynamicassessmentofvariationsinpupildiameterusingsweptsourceanteriorsegmentopticalcoherencetomographyafterphakiccollamerlensimplantation AT tejerinavictor dynamicassessmentofvariationsinpupildiameterusingsweptsourceanteriorsegmentopticalcoherencetomographyafterphakiccollamerlensimplantation AT druchkivvasyl dynamicassessmentofvariationsinpupildiameterusingsweptsourceanteriorsegmentopticalcoherencetomographyafterphakiccollamerlensimplantation AT mompeanblas dynamicassessmentofvariationsinpupildiameterusingsweptsourceanteriorsegmentopticalcoherencetomographyafterphakiccollamerlensimplantation AT ortegausobiagajulio dynamicassessmentofvariationsinpupildiameterusingsweptsourceanteriorsegmentopticalcoherencetomographyafterphakiccollamerlensimplantation AT bilbaocalabuigrafael dynamicassessmentofvariationsinpupildiameterusingsweptsourceanteriorsegmentopticalcoherencetomographyafterphakiccollamerlensimplantation |