Cargando…

A Deep Learning Model with High Standalone Performance for Diagnosis of Unruptured Intracranial Aneurysm

PURPOSE: This study aimed to investigate whether a deep learning model for automated detection of unruptured intracranial aneurysms on time-of-flight (TOF) magnetic resonance angiography (MRA) can achieve a target diagnostic performance comparable to that of human radiologists for approval from the...

Descripción completa

Detalles Bibliográficos
Autores principales: Joo, Bio, Choi, Hyun Seok, Ahn, Sung Soo, Cha, Jihoon, Won, So Yeon, Sohn, Beomseok, Kim, Hwiyoung, Han, Kyunghwa, Kim, Hwa Pyung, Choi, Jong Mun, Lee, Sang Min, Kim, Tae Gyu, Lee, Seung-Koo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Yonsei University College of Medicine 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8542476/
https://www.ncbi.nlm.nih.gov/pubmed/34672139
http://dx.doi.org/10.3349/ymj.2021.62.11.1052
Descripción
Sumario:PURPOSE: This study aimed to investigate whether a deep learning model for automated detection of unruptured intracranial aneurysms on time-of-flight (TOF) magnetic resonance angiography (MRA) can achieve a target diagnostic performance comparable to that of human radiologists for approval from the Korean Ministry of Food and Drug Safety as an artificial intelligence-applied software. MATERIALS AND METHODS: In this single-center, retrospective, confirmatory clinical trial, the diagnostic performance of the model was evaluated in a predetermined test set. After sample size estimation, the test set consisted of 135 aneurysm-containing examinations with 168 intracranial aneurysms and 197 aneurysm-free examinations. The target sensitivity and specificity were set as 87% and 92%, respectively. The patient-wise sensitivity and specificity of the model were analyzed. Moreover, the lesion-wise sensitivity and false-positive detection rate per case were also investigated. RESULTS: The sensitivity and specificity of the model were 91.11% [95% confidence interval (CI): 84.99, 95.32] and 93.91% (95% CI: 89.60, 96.81), respectively, which met the target performance values. The lesion-wise sensitivity was 92.26%. The overall false-positive detection rate per case was 0.123. Of the 168 aneurysms, 13 aneurysms from 12 examinations were missed by the model. CONCLUSION: The present deep learning model for automated detection of unruptured intracranial aneurysms on TOF MRA achieved the target diagnostic performance comparable to that of human radiologists. With high standalone performance, this model may be useful for accurate and efficient diagnosis of intracranial aneurysm.