Cargando…

Atrial High-Rate Event Incidence and Predictors in Patients With Permanent Pacemaker Implantation

Objective: The present study aims to investigate the incidence and predictors of atrial high-rate events (AHREs) in patients with permanent pacemaker implants. Methods: A total of 289 patients who were implanted with a dual-chamber pacemaker due to complete atrioventricular block or symptomatic sick...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Jian Hua, Chen, Guo Yao, Zheng, Hong, Chen, Quan He, Fu, Fa Yuan, Zhang, Fei Long, Chen, Liang Long, Wang, Wei Wei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8542700/
https://www.ncbi.nlm.nih.gov/pubmed/34708084
http://dx.doi.org/10.3389/fcvm.2021.728885
_version_ 1784589475132735488
author Chen, Jian Hua
Chen, Guo Yao
Zheng, Hong
Chen, Quan He
Fu, Fa Yuan
Zhang, Fei Long
Chen, Liang Long
Wang, Wei Wei
author_facet Chen, Jian Hua
Chen, Guo Yao
Zheng, Hong
Chen, Quan He
Fu, Fa Yuan
Zhang, Fei Long
Chen, Liang Long
Wang, Wei Wei
author_sort Chen, Jian Hua
collection PubMed
description Objective: The present study aims to investigate the incidence and predictors of atrial high-rate events (AHREs) in patients with permanent pacemaker implants. Methods: A total of 289 patients who were implanted with a dual-chamber pacemaker due to complete atrioventricular block or symptomatic sick sinus syndrome (SSS) and had no previous history of atrial fibrillation were included in the present study. AHREs are defined as events with an atrial frequency of ≥175 bpm and a duration of ≥5 min. The patients were divided into two groups according to whether or not AHREs were detected during the follow-up: group A (AHRE+, n = 91) and group N (AHRE–, n = 198). Results: During the 12-month follow-up period, AHREs were detected in 91 patients (31.5%). The multivariate Cox regression analysis revealed that patient age [odds ratio [OR] = 1.041; 95% confidence interval [CI], 1.018–1.064; and P < 0.001], pacemaker implantation due to symptomatic SSS (OR = 2.225; 95% CI, 1.227–4.036; and P = 0.008), and the percentage of atrial pacing after pacemaker implantation (OR = 1.010; 95% CI, 1.002–1.017; and P = 0.016) were independent AHRE predictors. Conclusion: The AHRE detection rate in patients with pacemaker implants was 31.5%. Patient age, pacemaker implantation due to symptomatic SSS, and the percentage of atrial pacing after pacemaker implantation were independent AHRE predictors.
format Online
Article
Text
id pubmed-8542700
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-85427002021-10-26 Atrial High-Rate Event Incidence and Predictors in Patients With Permanent Pacemaker Implantation Chen, Jian Hua Chen, Guo Yao Zheng, Hong Chen, Quan He Fu, Fa Yuan Zhang, Fei Long Chen, Liang Long Wang, Wei Wei Front Cardiovasc Med Cardiovascular Medicine Objective: The present study aims to investigate the incidence and predictors of atrial high-rate events (AHREs) in patients with permanent pacemaker implants. Methods: A total of 289 patients who were implanted with a dual-chamber pacemaker due to complete atrioventricular block or symptomatic sick sinus syndrome (SSS) and had no previous history of atrial fibrillation were included in the present study. AHREs are defined as events with an atrial frequency of ≥175 bpm and a duration of ≥5 min. The patients were divided into two groups according to whether or not AHREs were detected during the follow-up: group A (AHRE+, n = 91) and group N (AHRE–, n = 198). Results: During the 12-month follow-up period, AHREs were detected in 91 patients (31.5%). The multivariate Cox regression analysis revealed that patient age [odds ratio [OR] = 1.041; 95% confidence interval [CI], 1.018–1.064; and P < 0.001], pacemaker implantation due to symptomatic SSS (OR = 2.225; 95% CI, 1.227–4.036; and P = 0.008), and the percentage of atrial pacing after pacemaker implantation (OR = 1.010; 95% CI, 1.002–1.017; and P = 0.016) were independent AHRE predictors. Conclusion: The AHRE detection rate in patients with pacemaker implants was 31.5%. Patient age, pacemaker implantation due to symptomatic SSS, and the percentage of atrial pacing after pacemaker implantation were independent AHRE predictors. Frontiers Media S.A. 2021-10-11 /pmc/articles/PMC8542700/ /pubmed/34708084 http://dx.doi.org/10.3389/fcvm.2021.728885 Text en Copyright © 2021 Chen, Chen, Zheng, Chen, Fu, Zhang, Chen and Wang. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Cardiovascular Medicine
Chen, Jian Hua
Chen, Guo Yao
Zheng, Hong
Chen, Quan He
Fu, Fa Yuan
Zhang, Fei Long
Chen, Liang Long
Wang, Wei Wei
Atrial High-Rate Event Incidence and Predictors in Patients With Permanent Pacemaker Implantation
title Atrial High-Rate Event Incidence and Predictors in Patients With Permanent Pacemaker Implantation
title_full Atrial High-Rate Event Incidence and Predictors in Patients With Permanent Pacemaker Implantation
title_fullStr Atrial High-Rate Event Incidence and Predictors in Patients With Permanent Pacemaker Implantation
title_full_unstemmed Atrial High-Rate Event Incidence and Predictors in Patients With Permanent Pacemaker Implantation
title_short Atrial High-Rate Event Incidence and Predictors in Patients With Permanent Pacemaker Implantation
title_sort atrial high-rate event incidence and predictors in patients with permanent pacemaker implantation
topic Cardiovascular Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8542700/
https://www.ncbi.nlm.nih.gov/pubmed/34708084
http://dx.doi.org/10.3389/fcvm.2021.728885
work_keys_str_mv AT chenjianhua atrialhighrateeventincidenceandpredictorsinpatientswithpermanentpacemakerimplantation
AT chenguoyao atrialhighrateeventincidenceandpredictorsinpatientswithpermanentpacemakerimplantation
AT zhenghong atrialhighrateeventincidenceandpredictorsinpatientswithpermanentpacemakerimplantation
AT chenquanhe atrialhighrateeventincidenceandpredictorsinpatientswithpermanentpacemakerimplantation
AT fufayuan atrialhighrateeventincidenceandpredictorsinpatientswithpermanentpacemakerimplantation
AT zhangfeilong atrialhighrateeventincidenceandpredictorsinpatientswithpermanentpacemakerimplantation
AT chenlianglong atrialhighrateeventincidenceandpredictorsinpatientswithpermanentpacemakerimplantation
AT wangweiwei atrialhighrateeventincidenceandpredictorsinpatientswithpermanentpacemakerimplantation