Cargando…

Benefit of Stimulus Size V Perimetry for Patients With a Dense Central Scotoma From Leber's Hereditary Optic Neuropathy

PURPOSE: Leber's hereditary optic neuropathy (LHON) is the most common mtDNA optic neuropathy. It most frequently causes dense bilateral central scotomas that are often characterized in clinical studies by Humphrey visual field testing (HVF) using a stimulus size III. This provides numerical qu...

Descripción completa

Detalles Bibliográficos
Autores principales: Mejia-Vergara, Alvaro J., Sadun, Alfredo A., Chen, Alexander F., Smith, Michael F., Wall, Michael, Karanjia, Rustum
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8543387/
https://www.ncbi.nlm.nih.gov/pubmed/34673906
http://dx.doi.org/10.1167/tvst.10.12.31
_version_ 1784589624455200768
author Mejia-Vergara, Alvaro J.
Sadun, Alfredo A.
Chen, Alexander F.
Smith, Michael F.
Wall, Michael
Karanjia, Rustum
author_facet Mejia-Vergara, Alvaro J.
Sadun, Alfredo A.
Chen, Alexander F.
Smith, Michael F.
Wall, Michael
Karanjia, Rustum
author_sort Mejia-Vergara, Alvaro J.
collection PubMed
description PURPOSE: Leber's hereditary optic neuropathy (LHON) is the most common mtDNA optic neuropathy. It most frequently causes dense bilateral central scotomas that are often characterized in clinical studies by Humphrey visual field testing (HVF) using a stimulus size III. This provides numerical quantification of the visual field defect using the mean deviation. However, this size III testing strategy has limitations. We used stimulus size V to monitor these patients and evaluated intertest variability and dynamic range to determine the testing reliability and reproducibility. METHODS: This was a longitudinal retrospective cohort study comparing Stimulus III and Stimulus V HVF of 62 LHON patients who had reached the plateau stage of the disease. The intertest variability and mean defect were calculated for both stimulus sizes for 38 patients. The mean defect for stimulus size V was calculated using an algorithm developed by the University of Iowa Visual Field Reading Center. RESULTS: Stimulus size V HVFs had lower inter-test variability as measured by mean defect standard deviation (Z = 169, P < 0.01). The floor effect seen with Stimulus III HVF in LHON, was less pronounced with Stimulus V HVF. The correlation of stimulus size III and V mean defect was strong (r = 0.90, P < 0.01), and a mathematical model was constructed to calculate the Stimulus size V mean defect from the Stimulus size III results (MD(stimV) = 0.988 x MD(StimIII) + 1.35, R(2) = 0.82 P < 0.01). CONCLUSIONS: Stimulus size V HVF had lower intertest variability and a better dynamic range than Stimulus size III HVF in LHON patients. This makes the stimulus V HVF a more reliable metric to follow LHON patients especially in clinical trials. The mathematical model presented can be used to generate a Stimulus V equivalent mean defect from Stimulus III HVFs. TRANSLATIONAL RELEVANCE: Using Stimulus V HVF in LHON patients increases its ability to detect and quantify a response to treatment, making it a useful metric for future LHON clinical trials and the clinical setting.
format Online
Article
Text
id pubmed-8543387
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-85433872021-10-29 Benefit of Stimulus Size V Perimetry for Patients With a Dense Central Scotoma From Leber's Hereditary Optic Neuropathy Mejia-Vergara, Alvaro J. Sadun, Alfredo A. Chen, Alexander F. Smith, Michael F. Wall, Michael Karanjia, Rustum Transl Vis Sci Technol Article PURPOSE: Leber's hereditary optic neuropathy (LHON) is the most common mtDNA optic neuropathy. It most frequently causes dense bilateral central scotomas that are often characterized in clinical studies by Humphrey visual field testing (HVF) using a stimulus size III. This provides numerical quantification of the visual field defect using the mean deviation. However, this size III testing strategy has limitations. We used stimulus size V to monitor these patients and evaluated intertest variability and dynamic range to determine the testing reliability and reproducibility. METHODS: This was a longitudinal retrospective cohort study comparing Stimulus III and Stimulus V HVF of 62 LHON patients who had reached the plateau stage of the disease. The intertest variability and mean defect were calculated for both stimulus sizes for 38 patients. The mean defect for stimulus size V was calculated using an algorithm developed by the University of Iowa Visual Field Reading Center. RESULTS: Stimulus size V HVFs had lower inter-test variability as measured by mean defect standard deviation (Z = 169, P < 0.01). The floor effect seen with Stimulus III HVF in LHON, was less pronounced with Stimulus V HVF. The correlation of stimulus size III and V mean defect was strong (r = 0.90, P < 0.01), and a mathematical model was constructed to calculate the Stimulus size V mean defect from the Stimulus size III results (MD(stimV) = 0.988 x MD(StimIII) + 1.35, R(2) = 0.82 P < 0.01). CONCLUSIONS: Stimulus size V HVF had lower intertest variability and a better dynamic range than Stimulus size III HVF in LHON patients. This makes the stimulus V HVF a more reliable metric to follow LHON patients especially in clinical trials. The mathematical model presented can be used to generate a Stimulus V equivalent mean defect from Stimulus III HVFs. TRANSLATIONAL RELEVANCE: Using Stimulus V HVF in LHON patients increases its ability to detect and quantify a response to treatment, making it a useful metric for future LHON clinical trials and the clinical setting. The Association for Research in Vision and Ophthalmology 2021-10-21 /pmc/articles/PMC8543387/ /pubmed/34673906 http://dx.doi.org/10.1167/tvst.10.12.31 Text en Copyright 2021 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Article
Mejia-Vergara, Alvaro J.
Sadun, Alfredo A.
Chen, Alexander F.
Smith, Michael F.
Wall, Michael
Karanjia, Rustum
Benefit of Stimulus Size V Perimetry for Patients With a Dense Central Scotoma From Leber's Hereditary Optic Neuropathy
title Benefit of Stimulus Size V Perimetry for Patients With a Dense Central Scotoma From Leber's Hereditary Optic Neuropathy
title_full Benefit of Stimulus Size V Perimetry for Patients With a Dense Central Scotoma From Leber's Hereditary Optic Neuropathy
title_fullStr Benefit of Stimulus Size V Perimetry for Patients With a Dense Central Scotoma From Leber's Hereditary Optic Neuropathy
title_full_unstemmed Benefit of Stimulus Size V Perimetry for Patients With a Dense Central Scotoma From Leber's Hereditary Optic Neuropathy
title_short Benefit of Stimulus Size V Perimetry for Patients With a Dense Central Scotoma From Leber's Hereditary Optic Neuropathy
title_sort benefit of stimulus size v perimetry for patients with a dense central scotoma from leber's hereditary optic neuropathy
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8543387/
https://www.ncbi.nlm.nih.gov/pubmed/34673906
http://dx.doi.org/10.1167/tvst.10.12.31
work_keys_str_mv AT mejiavergaraalvaroj benefitofstimulussizevperimetryforpatientswithadensecentralscotomafromlebershereditaryopticneuropathy
AT sadunalfredoa benefitofstimulussizevperimetryforpatientswithadensecentralscotomafromlebershereditaryopticneuropathy
AT chenalexanderf benefitofstimulussizevperimetryforpatientswithadensecentralscotomafromlebershereditaryopticneuropathy
AT smithmichaelf benefitofstimulussizevperimetryforpatientswithadensecentralscotomafromlebershereditaryopticneuropathy
AT wallmichael benefitofstimulussizevperimetryforpatientswithadensecentralscotomafromlebershereditaryopticneuropathy
AT karanjiarustum benefitofstimulussizevperimetryforpatientswithadensecentralscotomafromlebershereditaryopticneuropathy