Cargando…
Benefit of Stimulus Size V Perimetry for Patients With a Dense Central Scotoma From Leber's Hereditary Optic Neuropathy
PURPOSE: Leber's hereditary optic neuropathy (LHON) is the most common mtDNA optic neuropathy. It most frequently causes dense bilateral central scotomas that are often characterized in clinical studies by Humphrey visual field testing (HVF) using a stimulus size III. This provides numerical qu...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Association for Research in Vision and Ophthalmology
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8543387/ https://www.ncbi.nlm.nih.gov/pubmed/34673906 http://dx.doi.org/10.1167/tvst.10.12.31 |
_version_ | 1784589624455200768 |
---|---|
author | Mejia-Vergara, Alvaro J. Sadun, Alfredo A. Chen, Alexander F. Smith, Michael F. Wall, Michael Karanjia, Rustum |
author_facet | Mejia-Vergara, Alvaro J. Sadun, Alfredo A. Chen, Alexander F. Smith, Michael F. Wall, Michael Karanjia, Rustum |
author_sort | Mejia-Vergara, Alvaro J. |
collection | PubMed |
description | PURPOSE: Leber's hereditary optic neuropathy (LHON) is the most common mtDNA optic neuropathy. It most frequently causes dense bilateral central scotomas that are often characterized in clinical studies by Humphrey visual field testing (HVF) using a stimulus size III. This provides numerical quantification of the visual field defect using the mean deviation. However, this size III testing strategy has limitations. We used stimulus size V to monitor these patients and evaluated intertest variability and dynamic range to determine the testing reliability and reproducibility. METHODS: This was a longitudinal retrospective cohort study comparing Stimulus III and Stimulus V HVF of 62 LHON patients who had reached the plateau stage of the disease. The intertest variability and mean defect were calculated for both stimulus sizes for 38 patients. The mean defect for stimulus size V was calculated using an algorithm developed by the University of Iowa Visual Field Reading Center. RESULTS: Stimulus size V HVFs had lower inter-test variability as measured by mean defect standard deviation (Z = 169, P < 0.01). The floor effect seen with Stimulus III HVF in LHON, was less pronounced with Stimulus V HVF. The correlation of stimulus size III and V mean defect was strong (r = 0.90, P < 0.01), and a mathematical model was constructed to calculate the Stimulus size V mean defect from the Stimulus size III results (MD(stimV) = 0.988 x MD(StimIII) + 1.35, R(2) = 0.82 P < 0.01). CONCLUSIONS: Stimulus size V HVF had lower intertest variability and a better dynamic range than Stimulus size III HVF in LHON patients. This makes the stimulus V HVF a more reliable metric to follow LHON patients especially in clinical trials. The mathematical model presented can be used to generate a Stimulus V equivalent mean defect from Stimulus III HVFs. TRANSLATIONAL RELEVANCE: Using Stimulus V HVF in LHON patients increases its ability to detect and quantify a response to treatment, making it a useful metric for future LHON clinical trials and the clinical setting. |
format | Online Article Text |
id | pubmed-8543387 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | The Association for Research in Vision and Ophthalmology |
record_format | MEDLINE/PubMed |
spelling | pubmed-85433872021-10-29 Benefit of Stimulus Size V Perimetry for Patients With a Dense Central Scotoma From Leber's Hereditary Optic Neuropathy Mejia-Vergara, Alvaro J. Sadun, Alfredo A. Chen, Alexander F. Smith, Michael F. Wall, Michael Karanjia, Rustum Transl Vis Sci Technol Article PURPOSE: Leber's hereditary optic neuropathy (LHON) is the most common mtDNA optic neuropathy. It most frequently causes dense bilateral central scotomas that are often characterized in clinical studies by Humphrey visual field testing (HVF) using a stimulus size III. This provides numerical quantification of the visual field defect using the mean deviation. However, this size III testing strategy has limitations. We used stimulus size V to monitor these patients and evaluated intertest variability and dynamic range to determine the testing reliability and reproducibility. METHODS: This was a longitudinal retrospective cohort study comparing Stimulus III and Stimulus V HVF of 62 LHON patients who had reached the plateau stage of the disease. The intertest variability and mean defect were calculated for both stimulus sizes for 38 patients. The mean defect for stimulus size V was calculated using an algorithm developed by the University of Iowa Visual Field Reading Center. RESULTS: Stimulus size V HVFs had lower inter-test variability as measured by mean defect standard deviation (Z = 169, P < 0.01). The floor effect seen with Stimulus III HVF in LHON, was less pronounced with Stimulus V HVF. The correlation of stimulus size III and V mean defect was strong (r = 0.90, P < 0.01), and a mathematical model was constructed to calculate the Stimulus size V mean defect from the Stimulus size III results (MD(stimV) = 0.988 x MD(StimIII) + 1.35, R(2) = 0.82 P < 0.01). CONCLUSIONS: Stimulus size V HVF had lower intertest variability and a better dynamic range than Stimulus size III HVF in LHON patients. This makes the stimulus V HVF a more reliable metric to follow LHON patients especially in clinical trials. The mathematical model presented can be used to generate a Stimulus V equivalent mean defect from Stimulus III HVFs. TRANSLATIONAL RELEVANCE: Using Stimulus V HVF in LHON patients increases its ability to detect and quantify a response to treatment, making it a useful metric for future LHON clinical trials and the clinical setting. The Association for Research in Vision and Ophthalmology 2021-10-21 /pmc/articles/PMC8543387/ /pubmed/34673906 http://dx.doi.org/10.1167/tvst.10.12.31 Text en Copyright 2021 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. |
spellingShingle | Article Mejia-Vergara, Alvaro J. Sadun, Alfredo A. Chen, Alexander F. Smith, Michael F. Wall, Michael Karanjia, Rustum Benefit of Stimulus Size V Perimetry for Patients With a Dense Central Scotoma From Leber's Hereditary Optic Neuropathy |
title | Benefit of Stimulus Size V Perimetry for Patients With a Dense Central Scotoma From Leber's Hereditary Optic Neuropathy |
title_full | Benefit of Stimulus Size V Perimetry for Patients With a Dense Central Scotoma From Leber's Hereditary Optic Neuropathy |
title_fullStr | Benefit of Stimulus Size V Perimetry for Patients With a Dense Central Scotoma From Leber's Hereditary Optic Neuropathy |
title_full_unstemmed | Benefit of Stimulus Size V Perimetry for Patients With a Dense Central Scotoma From Leber's Hereditary Optic Neuropathy |
title_short | Benefit of Stimulus Size V Perimetry for Patients With a Dense Central Scotoma From Leber's Hereditary Optic Neuropathy |
title_sort | benefit of stimulus size v perimetry for patients with a dense central scotoma from leber's hereditary optic neuropathy |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8543387/ https://www.ncbi.nlm.nih.gov/pubmed/34673906 http://dx.doi.org/10.1167/tvst.10.12.31 |
work_keys_str_mv | AT mejiavergaraalvaroj benefitofstimulussizevperimetryforpatientswithadensecentralscotomafromlebershereditaryopticneuropathy AT sadunalfredoa benefitofstimulussizevperimetryforpatientswithadensecentralscotomafromlebershereditaryopticneuropathy AT chenalexanderf benefitofstimulussizevperimetryforpatientswithadensecentralscotomafromlebershereditaryopticneuropathy AT smithmichaelf benefitofstimulussizevperimetryforpatientswithadensecentralscotomafromlebershereditaryopticneuropathy AT wallmichael benefitofstimulussizevperimetryforpatientswithadensecentralscotomafromlebershereditaryopticneuropathy AT karanjiarustum benefitofstimulussizevperimetryforpatientswithadensecentralscotomafromlebershereditaryopticneuropathy |