Cargando…
Development and Testing of an Algorithm to Prevent Medical Device–Related Pressure Injuries
We developed and tested the effectiveness of an algorithm to prevent medical device–related pressure injuries in intensive care unit patients. It was developed in four stages: literature review and analysis of medical records; preliminary algorithm development; validation of the preliminary algorith...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8543706/ https://www.ncbi.nlm.nih.gov/pubmed/34672226 http://dx.doi.org/10.1177/00469580211050219 |
_version_ | 1784589670809600000 |
---|---|
author | Seong, Yeong-Mi Lee, Hyejin Seo, Ji Min |
author_facet | Seong, Yeong-Mi Lee, Hyejin Seo, Ji Min |
author_sort | Seong, Yeong-Mi |
collection | PubMed |
description | We developed and tested the effectiveness of an algorithm to prevent medical device–related pressure injuries in intensive care unit patients. It was developed in four stages: literature review and analysis of medical records; preliminary algorithm development; validation of the preliminary algorithm by experts in two rounds; and practical feasibility verification of the revised algorithm by 109 intensive care unit nurses. To verify the algorithm’s effectiveness, we compared the incidence of medical device–related pressure injuries between 324 patients without algorithm application (control group) and 312 patients with algorithm application (experimental group). The outcomes were skin inspection of the medical device attachment, pressure injury evaluation, and implementation of pressure injury-preventive nursing care, based on the medical device type. The incidence rates were 1.46 per 100 devices (control group) and 1.19 per 100 devices (experimental group). Since there was no homogeneity in the previous score of the Braden scale in the experimental and control groups, the results regarding the incidence of pressure damage after applying the algorithm should be interpreted with care. Applying this algorithm was a safe intervention that helped prevent medical device–related pressure injuries in this population. |
format | Online Article Text |
id | pubmed-8543706 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-85437062021-10-26 Development and Testing of an Algorithm to Prevent Medical Device–Related Pressure Injuries Seong, Yeong-Mi Lee, Hyejin Seo, Ji Min Inquiry Original Research Article We developed and tested the effectiveness of an algorithm to prevent medical device–related pressure injuries in intensive care unit patients. It was developed in four stages: literature review and analysis of medical records; preliminary algorithm development; validation of the preliminary algorithm by experts in two rounds; and practical feasibility verification of the revised algorithm by 109 intensive care unit nurses. To verify the algorithm’s effectiveness, we compared the incidence of medical device–related pressure injuries between 324 patients without algorithm application (control group) and 312 patients with algorithm application (experimental group). The outcomes were skin inspection of the medical device attachment, pressure injury evaluation, and implementation of pressure injury-preventive nursing care, based on the medical device type. The incidence rates were 1.46 per 100 devices (control group) and 1.19 per 100 devices (experimental group). Since there was no homogeneity in the previous score of the Braden scale in the experimental and control groups, the results regarding the incidence of pressure damage after applying the algorithm should be interpreted with care. Applying this algorithm was a safe intervention that helped prevent medical device–related pressure injuries in this population. SAGE Publications 2021-10-21 /pmc/articles/PMC8543706/ /pubmed/34672226 http://dx.doi.org/10.1177/00469580211050219 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Research Article Seong, Yeong-Mi Lee, Hyejin Seo, Ji Min Development and Testing of an Algorithm to Prevent Medical Device–Related Pressure Injuries |
title | Development and Testing of an Algorithm to Prevent Medical Device–Related
Pressure Injuries |
title_full | Development and Testing of an Algorithm to Prevent Medical Device–Related
Pressure Injuries |
title_fullStr | Development and Testing of an Algorithm to Prevent Medical Device–Related
Pressure Injuries |
title_full_unstemmed | Development and Testing of an Algorithm to Prevent Medical Device–Related
Pressure Injuries |
title_short | Development and Testing of an Algorithm to Prevent Medical Device–Related
Pressure Injuries |
title_sort | development and testing of an algorithm to prevent medical device–related
pressure injuries |
topic | Original Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8543706/ https://www.ncbi.nlm.nih.gov/pubmed/34672226 http://dx.doi.org/10.1177/00469580211050219 |
work_keys_str_mv | AT seongyeongmi developmentandtestingofanalgorithmtopreventmedicaldevicerelatedpressureinjuries AT leehyejin developmentandtestingofanalgorithmtopreventmedicaldevicerelatedpressureinjuries AT seojimin developmentandtestingofanalgorithmtopreventmedicaldevicerelatedpressureinjuries |