Cargando…

XEN-augmented Baerveldt Failure: Three Different Revision Approaches for Pediatric Patients

AIM AND OBJECTIVE: Report three different solutions in case of XEN-augmented Baerveldt fails. BACKGROUND: Drainage devices have been used for refractory pediatric glaucoma. To avoid early hypotony and corneal damage, Mermoud et al. introduced the augmentation of a XEN implant with a Baerveldt tube....

Descripción completa

Detalles Bibliográficos
Autores principales: José, Patrícia, Pinto, Luís Abegão, Teixeira, Filipa Jorge
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Jaypee Brothers Medical Publishers 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8543748/
https://www.ncbi.nlm.nih.gov/pubmed/34720500
http://dx.doi.org/10.5005/jp-journals-10078-1307
Descripción
Sumario:AIM AND OBJECTIVE: Report three different solutions in case of XEN-augmented Baerveldt fails. BACKGROUND: Drainage devices have been used for refractory pediatric glaucoma. To avoid early hypotony and corneal damage, Mermoud et al. introduced the augmentation of a XEN implant with a Baerveldt tube. In some cases, this technique fails to lead to a high intraocular pressure (IOP) and surgical revision. CASE DESCRIPTION: Three cases of children with this combined implant needed surgical revision due to high IOP. Three different approaches were performed: XEN replacement in one case, stretching the Baerveldt's tube into the anterior chamber (AC) in the second case, and explant of the device followed by an implant of a new Baerveldt-250 in the same quadrant in the third case. Successful control of IOP (>18 mm Hg) was achieved in all patients under no topical treatment. CONCLUSION: Despite the attractiveness of the XEN-augmented Baerveldt implant in refractory pediatric glaucoma as an alternative to conventional surgery, we have to learn how to deal with failures. Three different approaches are presented with good short-term results. The long-term efficacy is yet to be assessed. CLINICAL SIGNIFICANCE: Describe three possible options when faced with a need for surgical revision in XEN-augmented Baerveldt implant. HOW TO CITE THIS ARTICLE: José P, Abegão Pinto L, Teixeira FJ. XEN-augmented Baerveldt Failure: Three Different Revision Approaches for Pediatric Patients. J Curr Glaucoma Pract 2021;15(2):96–98.