Cargando…
Effect of pupil size on posterior chamber phakic intraocular lens vault measurements
PURPOSE: The aim of this study was to measure the implantable collamer lens (ICL) vault changes with anterior segment optical coherence tomography (AS-OCT) after the implantation of the Visian posterior chamber phakic ICL with a central hole (V4c) in relation to the pupil size. METHODS: This retrosp...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8544034/ https://www.ncbi.nlm.nih.gov/pubmed/34427202 http://dx.doi.org/10.4103/ijo.IJO_3429_20 |
_version_ | 1784589733541707776 |
---|---|
author | Srirampur, Arjun Pesala, Veerendranath Mansoori, Tarannum Gadde, Aruna Kumari Kola, Pravalika |
author_facet | Srirampur, Arjun Pesala, Veerendranath Mansoori, Tarannum Gadde, Aruna Kumari Kola, Pravalika |
author_sort | Srirampur, Arjun |
collection | PubMed |
description | PURPOSE: The aim of this study was to measure the implantable collamer lens (ICL) vault changes with anterior segment optical coherence tomography (AS-OCT) after the implantation of the Visian posterior chamber phakic ICL with a central hole (V4c) in relation to the pupil size. METHODS: This retrospective observational pilot study included 32 eyes of 16 patients, who underwent V4c ICL implantation. ICL vault was measured with AS-OCT in undilated and fully dilate state of the pupil. Primary outcome measure was the change in the vault of V4c ICL at the maximum and minimum pupil size. RESULTS: Median (IQR) undilated and post-dilated vault measurement was 393.00 (335.50–493.50) microns and 421.00 (338.50–503.75) microns, respectively, which was not statistically significant (P = 0.44). CONCLUSION: No statistically significant difference was observed between the undilated and post-dilated ICL vault measurements. Hence, the postoperative vault can be measured either in resting, undilated state or fully dilated state of the pupil and would be similar irrespective of the pupil size. |
format | Online Article Text |
id | pubmed-8544034 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-85440342021-10-29 Effect of pupil size on posterior chamber phakic intraocular lens vault measurements Srirampur, Arjun Pesala, Veerendranath Mansoori, Tarannum Gadde, Aruna Kumari Kola, Pravalika Indian J Ophthalmol Original Article PURPOSE: The aim of this study was to measure the implantable collamer lens (ICL) vault changes with anterior segment optical coherence tomography (AS-OCT) after the implantation of the Visian posterior chamber phakic ICL with a central hole (V4c) in relation to the pupil size. METHODS: This retrospective observational pilot study included 32 eyes of 16 patients, who underwent V4c ICL implantation. ICL vault was measured with AS-OCT in undilated and fully dilate state of the pupil. Primary outcome measure was the change in the vault of V4c ICL at the maximum and minimum pupil size. RESULTS: Median (IQR) undilated and post-dilated vault measurement was 393.00 (335.50–493.50) microns and 421.00 (338.50–503.75) microns, respectively, which was not statistically significant (P = 0.44). CONCLUSION: No statistically significant difference was observed between the undilated and post-dilated ICL vault measurements. Hence, the postoperative vault can be measured either in resting, undilated state or fully dilated state of the pupil and would be similar irrespective of the pupil size. Wolters Kluwer - Medknow 2021-09 2021-08-25 /pmc/articles/PMC8544034/ /pubmed/34427202 http://dx.doi.org/10.4103/ijo.IJO_3429_20 Text en Copyright: © 2021 Indian Journal of Ophthalmology https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 4.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Srirampur, Arjun Pesala, Veerendranath Mansoori, Tarannum Gadde, Aruna Kumari Kola, Pravalika Effect of pupil size on posterior chamber phakic intraocular lens vault measurements |
title | Effect of pupil size on posterior chamber phakic intraocular lens vault measurements |
title_full | Effect of pupil size on posterior chamber phakic intraocular lens vault measurements |
title_fullStr | Effect of pupil size on posterior chamber phakic intraocular lens vault measurements |
title_full_unstemmed | Effect of pupil size on posterior chamber phakic intraocular lens vault measurements |
title_short | Effect of pupil size on posterior chamber phakic intraocular lens vault measurements |
title_sort | effect of pupil size on posterior chamber phakic intraocular lens vault measurements |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8544034/ https://www.ncbi.nlm.nih.gov/pubmed/34427202 http://dx.doi.org/10.4103/ijo.IJO_3429_20 |
work_keys_str_mv | AT srirampurarjun effectofpupilsizeonposteriorchamberphakicintraocularlensvaultmeasurements AT pesalaveerendranath effectofpupilsizeonposteriorchamberphakicintraocularlensvaultmeasurements AT mansooritarannum effectofpupilsizeonposteriorchamberphakicintraocularlensvaultmeasurements AT gaddearunakumari effectofpupilsizeonposteriorchamberphakicintraocularlensvaultmeasurements AT kolapravalika effectofpupilsizeonposteriorchamberphakicintraocularlensvaultmeasurements |