Cargando…
A Preliminary Study on the Feasibility of the Quantitative Parameters of Dual-Energy Computed Tomography Enterography in the Assessment of the Activity of Intestinal Crohn’s Disease
OBJECTIVE: To investigate the value of dual energy CT enterography (DECTE) in evaluating the activity of Crohn’s disease (CD). METHODS: The endoscopy and imaging data of 29 patients with CD confirmed by clinic and pathology were analyzed retrospectively. The clinical CD activity index (CDAI) was use...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8544122/ https://www.ncbi.nlm.nih.gov/pubmed/34707396 http://dx.doi.org/10.2147/IJGM.S331763 |
_version_ | 1784589754936852480 |
---|---|
author | Xiao, Wei-xiong Zhu, Yu-ting Zhang, Zhi-chao Luo, Min Ma, Ming-ping |
author_facet | Xiao, Wei-xiong Zhu, Yu-ting Zhang, Zhi-chao Luo, Min Ma, Ming-ping |
author_sort | Xiao, Wei-xiong |
collection | PubMed |
description | OBJECTIVE: To investigate the value of dual energy CT enterography (DECTE) in evaluating the activity of Crohn’s disease (CD). METHODS: The endoscopy and imaging data of 29 patients with CD confirmed by clinic and pathology were analyzed retrospectively. The clinical CD activity index (CDAI) was used as the disease activity grouping standard, 29 patients with CD were grouped into activity groups, 18 patients in the active group (CDAI ≥ 150) with 36 intestinal segments, and 11 patients in the remission group (CDAI < 150) with 20 intestinal segments.The virtual single energy CT value, slope of energy spectrum curve and iodine content were analyzed to evaluate the evaluation of intestinal CD activity by DECTE. RESULTS: There were statistically significant differences in virtual single energy CT value (except 90 keV and 100 keV virtual single energy CT value), curve slope and iodine content between remission group and active group (P < 0.05), and has more diagnostic value for active phase (AUC > 0.5). ① Virtual single energy CT value: the AUC of 60 keV in arterial phase was the highest (0.924). The specificity of diagnosing CD in active stage was high (95%). ② Curve slope: the AUC of portal vein phase was the largest (0.731). The specificity of diagnosing CD in active stage was higher (85%). ③ Iodine content: the AUC of arterial phase was the highest (0.885). The specificity of diagnosing CD lesions in the active stage was 100%. CONCLUSION: The virtual single energy CT value, energy spectrum curve slope and iodine content can provide reference for clinical accurate diagnosis of CD activity. |
format | Online Article Text |
id | pubmed-8544122 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Dove |
record_format | MEDLINE/PubMed |
spelling | pubmed-85441222021-10-26 A Preliminary Study on the Feasibility of the Quantitative Parameters of Dual-Energy Computed Tomography Enterography in the Assessment of the Activity of Intestinal Crohn’s Disease Xiao, Wei-xiong Zhu, Yu-ting Zhang, Zhi-chao Luo, Min Ma, Ming-ping Int J Gen Med Original Research OBJECTIVE: To investigate the value of dual energy CT enterography (DECTE) in evaluating the activity of Crohn’s disease (CD). METHODS: The endoscopy and imaging data of 29 patients with CD confirmed by clinic and pathology were analyzed retrospectively. The clinical CD activity index (CDAI) was used as the disease activity grouping standard, 29 patients with CD were grouped into activity groups, 18 patients in the active group (CDAI ≥ 150) with 36 intestinal segments, and 11 patients in the remission group (CDAI < 150) with 20 intestinal segments.The virtual single energy CT value, slope of energy spectrum curve and iodine content were analyzed to evaluate the evaluation of intestinal CD activity by DECTE. RESULTS: There were statistically significant differences in virtual single energy CT value (except 90 keV and 100 keV virtual single energy CT value), curve slope and iodine content between remission group and active group (P < 0.05), and has more diagnostic value for active phase (AUC > 0.5). ① Virtual single energy CT value: the AUC of 60 keV in arterial phase was the highest (0.924). The specificity of diagnosing CD in active stage was high (95%). ② Curve slope: the AUC of portal vein phase was the largest (0.731). The specificity of diagnosing CD in active stage was higher (85%). ③ Iodine content: the AUC of arterial phase was the highest (0.885). The specificity of diagnosing CD lesions in the active stage was 100%. CONCLUSION: The virtual single energy CT value, energy spectrum curve slope and iodine content can provide reference for clinical accurate diagnosis of CD activity. Dove 2021-10-21 /pmc/articles/PMC8544122/ /pubmed/34707396 http://dx.doi.org/10.2147/IJGM.S331763 Text en © 2021 Xiao et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
spellingShingle | Original Research Xiao, Wei-xiong Zhu, Yu-ting Zhang, Zhi-chao Luo, Min Ma, Ming-ping A Preliminary Study on the Feasibility of the Quantitative Parameters of Dual-Energy Computed Tomography Enterography in the Assessment of the Activity of Intestinal Crohn’s Disease |
title | A Preliminary Study on the Feasibility of the Quantitative Parameters of Dual-Energy Computed Tomography Enterography in the Assessment of the Activity of Intestinal Crohn’s Disease |
title_full | A Preliminary Study on the Feasibility of the Quantitative Parameters of Dual-Energy Computed Tomography Enterography in the Assessment of the Activity of Intestinal Crohn’s Disease |
title_fullStr | A Preliminary Study on the Feasibility of the Quantitative Parameters of Dual-Energy Computed Tomography Enterography in the Assessment of the Activity of Intestinal Crohn’s Disease |
title_full_unstemmed | A Preliminary Study on the Feasibility of the Quantitative Parameters of Dual-Energy Computed Tomography Enterography in the Assessment of the Activity of Intestinal Crohn’s Disease |
title_short | A Preliminary Study on the Feasibility of the Quantitative Parameters of Dual-Energy Computed Tomography Enterography in the Assessment of the Activity of Intestinal Crohn’s Disease |
title_sort | preliminary study on the feasibility of the quantitative parameters of dual-energy computed tomography enterography in the assessment of the activity of intestinal crohn’s disease |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8544122/ https://www.ncbi.nlm.nih.gov/pubmed/34707396 http://dx.doi.org/10.2147/IJGM.S331763 |
work_keys_str_mv | AT xiaoweixiong apreliminarystudyonthefeasibilityofthequantitativeparametersofdualenergycomputedtomographyenterographyintheassessmentoftheactivityofintestinalcrohnsdisease AT zhuyuting apreliminarystudyonthefeasibilityofthequantitativeparametersofdualenergycomputedtomographyenterographyintheassessmentoftheactivityofintestinalcrohnsdisease AT zhangzhichao apreliminarystudyonthefeasibilityofthequantitativeparametersofdualenergycomputedtomographyenterographyintheassessmentoftheactivityofintestinalcrohnsdisease AT luomin apreliminarystudyonthefeasibilityofthequantitativeparametersofdualenergycomputedtomographyenterographyintheassessmentoftheactivityofintestinalcrohnsdisease AT mamingping apreliminarystudyonthefeasibilityofthequantitativeparametersofdualenergycomputedtomographyenterographyintheassessmentoftheactivityofintestinalcrohnsdisease AT xiaoweixiong preliminarystudyonthefeasibilityofthequantitativeparametersofdualenergycomputedtomographyenterographyintheassessmentoftheactivityofintestinalcrohnsdisease AT zhuyuting preliminarystudyonthefeasibilityofthequantitativeparametersofdualenergycomputedtomographyenterographyintheassessmentoftheactivityofintestinalcrohnsdisease AT zhangzhichao preliminarystudyonthefeasibilityofthequantitativeparametersofdualenergycomputedtomographyenterographyintheassessmentoftheactivityofintestinalcrohnsdisease AT luomin preliminarystudyonthefeasibilityofthequantitativeparametersofdualenergycomputedtomographyenterographyintheassessmentoftheactivityofintestinalcrohnsdisease AT mamingping preliminarystudyonthefeasibilityofthequantitativeparametersofdualenergycomputedtomographyenterographyintheassessmentoftheactivityofintestinalcrohnsdisease |