Cargando…

Clinical Outcomes, Contrast Sensitivity, Reading Performance and Patient Satisfaction Following Bilateral Implantation of AT LARA 829MP EDoF IOLs

PURPOSE: To evaluate the visual outcomes, contrast sensitivity, reading performance and patient satisfaction after bilateral implantation of AT LARA extended depth of focus (EDoF) intraocular lenses (IOLs). METHODS: Patients undergoing phacoemulsification for age-related cataract and satisfying the...

Descripción completa

Detalles Bibliográficos
Autores principales: Ganesh, Sri, Brar, Sheetal, RP, Nikhil, Rathod, Dishitha
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8544275/
https://www.ncbi.nlm.nih.gov/pubmed/34707344
http://dx.doi.org/10.2147/OPTH.S331860
_version_ 1784589781274984448
author Ganesh, Sri
Brar, Sheetal
RP, Nikhil
Rathod, Dishitha
author_facet Ganesh, Sri
Brar, Sheetal
RP, Nikhil
Rathod, Dishitha
author_sort Ganesh, Sri
collection PubMed
description PURPOSE: To evaluate the visual outcomes, contrast sensitivity, reading performance and patient satisfaction after bilateral implantation of AT LARA extended depth of focus (EDoF) intraocular lenses (IOLs). METHODS: Patients undergoing phacoemulsification for age-related cataract and satisfying the eligibility criteria underwent bilateral implantation with AT LARA EDoF IOLs (Carl Zeiss Meditec, Jena, Germany). At follow-up visits of 1, 3, 6 and 12 months, binocular uncorrected and corrected distance, intermediate and near visual acuity, reading performance, defocus curve, contrast sensitivity and patient satisfaction for dysphotopsia and spectacle independence were evaluated. RESULTS: A total of 60 eyes from 30 patients with a mean age of 65.40±7.71 years were included in the study. At 12 months, 83% of patients (n=25) had binocular cumulative uncorrected distance visual acuity (UDVA) of 20/20 or better. Postoperative spherical equivalent refraction accuracy was within ±0.50 D for 95% of eyes (n=57) and refractive cylinder accuracy was within ≤0.50 D in 95% of eyes (n=57). The mean binocular uncorrected near visual acuity (UNVA) was 0.16±0.09 logMAR, and the mean uncorrected intermediate visual acuity (UIVA) at 60 and 80 cm was 0.01±0.09 and 0.03±0.08 logMAR, respectively, at 12 months. Reading speeds at 40, 60 and 80 cm showed improvement over time. No patient had complaints of severe dysphotopsia and none of the patients required glasses for any activity. No eye underwent YAG-laser capsulotomy for significant posterior capsule opacification at the end of mean follow-up. CONCLUSION: In our limited experience of 30 patients at 12 months, AT LARA EDoF IOLs resulted in excellent visual outcomes for uncorrected distance, intermediate and near visual acuity. The incidence of dysphotopsia and spectacle dependence was low, resulting in good patient satisfaction. TRIAL REGISTRY: CTRI/2020/08/027105 (www.ctri.nic.in).
format Online
Article
Text
id pubmed-8544275
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-85442752021-10-26 Clinical Outcomes, Contrast Sensitivity, Reading Performance and Patient Satisfaction Following Bilateral Implantation of AT LARA 829MP EDoF IOLs Ganesh, Sri Brar, Sheetal RP, Nikhil Rathod, Dishitha Clin Ophthalmol Original Research PURPOSE: To evaluate the visual outcomes, contrast sensitivity, reading performance and patient satisfaction after bilateral implantation of AT LARA extended depth of focus (EDoF) intraocular lenses (IOLs). METHODS: Patients undergoing phacoemulsification for age-related cataract and satisfying the eligibility criteria underwent bilateral implantation with AT LARA EDoF IOLs (Carl Zeiss Meditec, Jena, Germany). At follow-up visits of 1, 3, 6 and 12 months, binocular uncorrected and corrected distance, intermediate and near visual acuity, reading performance, defocus curve, contrast sensitivity and patient satisfaction for dysphotopsia and spectacle independence were evaluated. RESULTS: A total of 60 eyes from 30 patients with a mean age of 65.40±7.71 years were included in the study. At 12 months, 83% of patients (n=25) had binocular cumulative uncorrected distance visual acuity (UDVA) of 20/20 or better. Postoperative spherical equivalent refraction accuracy was within ±0.50 D for 95% of eyes (n=57) and refractive cylinder accuracy was within ≤0.50 D in 95% of eyes (n=57). The mean binocular uncorrected near visual acuity (UNVA) was 0.16±0.09 logMAR, and the mean uncorrected intermediate visual acuity (UIVA) at 60 and 80 cm was 0.01±0.09 and 0.03±0.08 logMAR, respectively, at 12 months. Reading speeds at 40, 60 and 80 cm showed improvement over time. No patient had complaints of severe dysphotopsia and none of the patients required glasses for any activity. No eye underwent YAG-laser capsulotomy for significant posterior capsule opacification at the end of mean follow-up. CONCLUSION: In our limited experience of 30 patients at 12 months, AT LARA EDoF IOLs resulted in excellent visual outcomes for uncorrected distance, intermediate and near visual acuity. The incidence of dysphotopsia and spectacle dependence was low, resulting in good patient satisfaction. TRIAL REGISTRY: CTRI/2020/08/027105 (www.ctri.nic.in). Dove 2021-10-21 /pmc/articles/PMC8544275/ /pubmed/34707344 http://dx.doi.org/10.2147/OPTH.S331860 Text en © 2021 Ganesh et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Ganesh, Sri
Brar, Sheetal
RP, Nikhil
Rathod, Dishitha
Clinical Outcomes, Contrast Sensitivity, Reading Performance and Patient Satisfaction Following Bilateral Implantation of AT LARA 829MP EDoF IOLs
title Clinical Outcomes, Contrast Sensitivity, Reading Performance and Patient Satisfaction Following Bilateral Implantation of AT LARA 829MP EDoF IOLs
title_full Clinical Outcomes, Contrast Sensitivity, Reading Performance and Patient Satisfaction Following Bilateral Implantation of AT LARA 829MP EDoF IOLs
title_fullStr Clinical Outcomes, Contrast Sensitivity, Reading Performance and Patient Satisfaction Following Bilateral Implantation of AT LARA 829MP EDoF IOLs
title_full_unstemmed Clinical Outcomes, Contrast Sensitivity, Reading Performance and Patient Satisfaction Following Bilateral Implantation of AT LARA 829MP EDoF IOLs
title_short Clinical Outcomes, Contrast Sensitivity, Reading Performance and Patient Satisfaction Following Bilateral Implantation of AT LARA 829MP EDoF IOLs
title_sort clinical outcomes, contrast sensitivity, reading performance and patient satisfaction following bilateral implantation of at lara 829mp edof iols
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8544275/
https://www.ncbi.nlm.nih.gov/pubmed/34707344
http://dx.doi.org/10.2147/OPTH.S331860
work_keys_str_mv AT ganeshsri clinicaloutcomescontrastsensitivityreadingperformanceandpatientsatisfactionfollowingbilateralimplantationofatlara829mpedofiols
AT brarsheetal clinicaloutcomescontrastsensitivityreadingperformanceandpatientsatisfactionfollowingbilateralimplantationofatlara829mpedofiols
AT rpnikhil clinicaloutcomescontrastsensitivityreadingperformanceandpatientsatisfactionfollowingbilateralimplantationofatlara829mpedofiols
AT rathoddishitha clinicaloutcomescontrastsensitivityreadingperformanceandpatientsatisfactionfollowingbilateralimplantationofatlara829mpedofiols