Cargando…

Accurate Measurement of Agatston Score Using kVp-Independent Reconstruction Algorithm for Ultra-High-Pitch Sn150 kVp CT

OBJECTIVE: To investigate the accuracy of the Agatston score obtained with the ultra-high-pitch (UHP) acquisition mode using tin-filter spectral shaping (Sn150 kVp) and a kVp-independent reconstruction algorithm to reduce the radiation dose. MATERIALS AND METHODS: This prospective study included 114...

Descripción completa

Detalles Bibliográficos
Autores principales: Hu, Xi, Tao, Xinwei, Zhang, Yueqiao, Niu, Zhongfeng, Zhang, Yong, Allmendinger, Thomas, Kuang, Yu, Chen, Bin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8546135/
https://www.ncbi.nlm.nih.gov/pubmed/34431246
http://dx.doi.org/10.3348/kjr.2021.0050
_version_ 1784590127890169856
author Hu, Xi
Tao, Xinwei
Zhang, Yueqiao
Niu, Zhongfeng
Zhang, Yong
Allmendinger, Thomas
Kuang, Yu
Chen, Bin
author_facet Hu, Xi
Tao, Xinwei
Zhang, Yueqiao
Niu, Zhongfeng
Zhang, Yong
Allmendinger, Thomas
Kuang, Yu
Chen, Bin
author_sort Hu, Xi
collection PubMed
description OBJECTIVE: To investigate the accuracy of the Agatston score obtained with the ultra-high-pitch (UHP) acquisition mode using tin-filter spectral shaping (Sn150 kVp) and a kVp-independent reconstruction algorithm to reduce the radiation dose. MATERIALS AND METHODS: This prospective study included 114 patients (mean ± standard deviation, 60.3 ± 9.8 years; 74 male) who underwent a standard 120 kVp scan and an additional UHP Sn150 kVp scan for coronary artery calcification scoring (CACS). These two datasets were reconstructed using a standard reconstruction algorithm (120 kVp + Qr36d, protocol A; Sn150 kVp + Qr36d, protocol B). In addition, the Sn150 kVp dataset was reconstructed using a kVp-independent reconstruction algorithm (Sn150 kVp + Sa36d, protocol C). The Agatston scores for protocols A and B, as well as protocols A and C, were compared. The agreement between the scores was assessed using the intraclass correlation coefficient (ICC) and the Bland–Altman plot. The radiation doses for the 120 kVp and UHP Sn150 kVp acquisition modes were also compared. RESULTS: No significant difference was observed in the Agatston score for protocols A (median, 63.05; interquartile range [IQR], 0–232.28) and C (median, 60.25; IQR, 0–195.20) (p = 0.060). The mean difference in the Agatston score for protocols A and C was relatively small (−7.82) and with the limits of agreement from −65.20 to 49.56 (ICC = 0.997). The Agatston score for protocol B (median, 34.85; IQR, 0–120.73) was significantly underestimated compared with that for protocol A (p < 0.001). The UHP Sn150 kVp mode facilitated an effective radiation dose reduction by approximately 30% (0.58 vs. 0.82 mSv, p < 0.001) from that associated with the standard 120 kVp mode. CONCLUSION: The Agatston scores for CACS with the UHP Sn150 kVp mode with a kVp-independent reconstruction algorithm and the standard 120 kVp demonstrated excellent agreement with a small mean difference and narrow agreement limits. The UHP Sn150 kVp mode allowed a significant reduction in the radiation dose.
format Online
Article
Text
id pubmed-8546135
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-85461352021-11-06 Accurate Measurement of Agatston Score Using kVp-Independent Reconstruction Algorithm for Ultra-High-Pitch Sn150 kVp CT Hu, Xi Tao, Xinwei Zhang, Yueqiao Niu, Zhongfeng Zhang, Yong Allmendinger, Thomas Kuang, Yu Chen, Bin Korean J Radiol Cardiovascular Imaging OBJECTIVE: To investigate the accuracy of the Agatston score obtained with the ultra-high-pitch (UHP) acquisition mode using tin-filter spectral shaping (Sn150 kVp) and a kVp-independent reconstruction algorithm to reduce the radiation dose. MATERIALS AND METHODS: This prospective study included 114 patients (mean ± standard deviation, 60.3 ± 9.8 years; 74 male) who underwent a standard 120 kVp scan and an additional UHP Sn150 kVp scan for coronary artery calcification scoring (CACS). These two datasets were reconstructed using a standard reconstruction algorithm (120 kVp + Qr36d, protocol A; Sn150 kVp + Qr36d, protocol B). In addition, the Sn150 kVp dataset was reconstructed using a kVp-independent reconstruction algorithm (Sn150 kVp + Sa36d, protocol C). The Agatston scores for protocols A and B, as well as protocols A and C, were compared. The agreement between the scores was assessed using the intraclass correlation coefficient (ICC) and the Bland–Altman plot. The radiation doses for the 120 kVp and UHP Sn150 kVp acquisition modes were also compared. RESULTS: No significant difference was observed in the Agatston score for protocols A (median, 63.05; interquartile range [IQR], 0–232.28) and C (median, 60.25; IQR, 0–195.20) (p = 0.060). The mean difference in the Agatston score for protocols A and C was relatively small (−7.82) and with the limits of agreement from −65.20 to 49.56 (ICC = 0.997). The Agatston score for protocol B (median, 34.85; IQR, 0–120.73) was significantly underestimated compared with that for protocol A (p < 0.001). The UHP Sn150 kVp mode facilitated an effective radiation dose reduction by approximately 30% (0.58 vs. 0.82 mSv, p < 0.001) from that associated with the standard 120 kVp mode. CONCLUSION: The Agatston scores for CACS with the UHP Sn150 kVp mode with a kVp-independent reconstruction algorithm and the standard 120 kVp demonstrated excellent agreement with a small mean difference and narrow agreement limits. The UHP Sn150 kVp mode allowed a significant reduction in the radiation dose. The Korean Society of Radiology 2021-11 2021-08-19 /pmc/articles/PMC8546135/ /pubmed/34431246 http://dx.doi.org/10.3348/kjr.2021.0050 Text en Copyright © 2021 The Korean Society of Radiology https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Cardiovascular Imaging
Hu, Xi
Tao, Xinwei
Zhang, Yueqiao
Niu, Zhongfeng
Zhang, Yong
Allmendinger, Thomas
Kuang, Yu
Chen, Bin
Accurate Measurement of Agatston Score Using kVp-Independent Reconstruction Algorithm for Ultra-High-Pitch Sn150 kVp CT
title Accurate Measurement of Agatston Score Using kVp-Independent Reconstruction Algorithm for Ultra-High-Pitch Sn150 kVp CT
title_full Accurate Measurement of Agatston Score Using kVp-Independent Reconstruction Algorithm for Ultra-High-Pitch Sn150 kVp CT
title_fullStr Accurate Measurement of Agatston Score Using kVp-Independent Reconstruction Algorithm for Ultra-High-Pitch Sn150 kVp CT
title_full_unstemmed Accurate Measurement of Agatston Score Using kVp-Independent Reconstruction Algorithm for Ultra-High-Pitch Sn150 kVp CT
title_short Accurate Measurement of Agatston Score Using kVp-Independent Reconstruction Algorithm for Ultra-High-Pitch Sn150 kVp CT
title_sort accurate measurement of agatston score using kvp-independent reconstruction algorithm for ultra-high-pitch sn150 kvp ct
topic Cardiovascular Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8546135/
https://www.ncbi.nlm.nih.gov/pubmed/34431246
http://dx.doi.org/10.3348/kjr.2021.0050
work_keys_str_mv AT huxi accuratemeasurementofagatstonscoreusingkvpindependentreconstructionalgorithmforultrahighpitchsn150kvpct
AT taoxinwei accuratemeasurementofagatstonscoreusingkvpindependentreconstructionalgorithmforultrahighpitchsn150kvpct
AT zhangyueqiao accuratemeasurementofagatstonscoreusingkvpindependentreconstructionalgorithmforultrahighpitchsn150kvpct
AT niuzhongfeng accuratemeasurementofagatstonscoreusingkvpindependentreconstructionalgorithmforultrahighpitchsn150kvpct
AT zhangyong accuratemeasurementofagatstonscoreusingkvpindependentreconstructionalgorithmforultrahighpitchsn150kvpct
AT allmendingerthomas accuratemeasurementofagatstonscoreusingkvpindependentreconstructionalgorithmforultrahighpitchsn150kvpct
AT kuangyu accuratemeasurementofagatstonscoreusingkvpindependentreconstructionalgorithmforultrahighpitchsn150kvpct
AT chenbin accuratemeasurementofagatstonscoreusingkvpindependentreconstructionalgorithmforultrahighpitchsn150kvpct