Cargando…

Computer-assisted preoperative planning of reduction of and osteosynthesis of scapular fracture: A case report

INTRODUCTION: Reports on the use of computer-assisted trauma surgery of comminuted scapula fracture are still quite rare. In this article, we present a case of comminuted scapula fracture, the surgical reconstruction of which was pre-operatively planned using a complex software solution. MATERIALS A...

Descripción completa

Detalles Bibliográficos
Autores principales: Madeja, Roman, Bajor, Grzegorz, Klima, Ondrej, Bialy, Lubor, Pometlova, Jana
Formato: Online Artículo Texto
Lenguaje:English
Publicado: De Gruyter 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8546289/
https://www.ncbi.nlm.nih.gov/pubmed/34722895
http://dx.doi.org/10.1515/med-2021-0338
_version_ 1784590162792022016
author Madeja, Roman
Bajor, Grzegorz
Klima, Ondrej
Bialy, Lubor
Pometlova, Jana
author_facet Madeja, Roman
Bajor, Grzegorz
Klima, Ondrej
Bialy, Lubor
Pometlova, Jana
author_sort Madeja, Roman
collection PubMed
description INTRODUCTION: Reports on the use of computer-assisted trauma surgery of comminuted scapula fracture are still quite rare. In this article, we present a case of comminuted scapula fracture, the surgical reconstruction of which was pre-operatively planned using a complex software solution. MATERIALS AND METHODS: For surgical planning of the fracture, we used the TraumaTech software facilitating virtual reconstruction (both manual and automatic), surgery planning, design of the implant, planning of screw placement and lengths, and production of a 3D print model of the fracture and the implant. The software also supported ordering such custom-made plate from a plate producer who was capable of fast and precise production of the plate. RESULTS: The surgery using the custom-ordered plate was successful. The actual used screw lengths did not differ from the planned ones by more than 2 mm. One year after the surgery, the patient was capable of more demanding activities and doing sports activities. CONCLUSION: This approach provides a great way to prevent complications of the surgery and to shorten its duration. To the best of our knowledge, this is the first description of the treatment of a scapula comminuted fracture utilizing computer-assisted preoperative planning.
format Online
Article
Text
id pubmed-8546289
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher De Gruyter
record_format MEDLINE/PubMed
spelling pubmed-85462892021-10-29 Computer-assisted preoperative planning of reduction of and osteosynthesis of scapular fracture: A case report Madeja, Roman Bajor, Grzegorz Klima, Ondrej Bialy, Lubor Pometlova, Jana Open Med (Wars) Case Report INTRODUCTION: Reports on the use of computer-assisted trauma surgery of comminuted scapula fracture are still quite rare. In this article, we present a case of comminuted scapula fracture, the surgical reconstruction of which was pre-operatively planned using a complex software solution. MATERIALS AND METHODS: For surgical planning of the fracture, we used the TraumaTech software facilitating virtual reconstruction (both manual and automatic), surgery planning, design of the implant, planning of screw placement and lengths, and production of a 3D print model of the fracture and the implant. The software also supported ordering such custom-made plate from a plate producer who was capable of fast and precise production of the plate. RESULTS: The surgery using the custom-ordered plate was successful. The actual used screw lengths did not differ from the planned ones by more than 2 mm. One year after the surgery, the patient was capable of more demanding activities and doing sports activities. CONCLUSION: This approach provides a great way to prevent complications of the surgery and to shorten its duration. To the best of our knowledge, this is the first description of the treatment of a scapula comminuted fracture utilizing computer-assisted preoperative planning. De Gruyter 2021-10-25 /pmc/articles/PMC8546289/ /pubmed/34722895 http://dx.doi.org/10.1515/med-2021-0338 Text en © 2021 Roman Madeja et al., published by De Gruyter https://creativecommons.org/licenses/by/4.0/This work is licensed under the Creative Commons Attribution 4.0 International License.
spellingShingle Case Report
Madeja, Roman
Bajor, Grzegorz
Klima, Ondrej
Bialy, Lubor
Pometlova, Jana
Computer-assisted preoperative planning of reduction of and osteosynthesis of scapular fracture: A case report
title Computer-assisted preoperative planning of reduction of and osteosynthesis of scapular fracture: A case report
title_full Computer-assisted preoperative planning of reduction of and osteosynthesis of scapular fracture: A case report
title_fullStr Computer-assisted preoperative planning of reduction of and osteosynthesis of scapular fracture: A case report
title_full_unstemmed Computer-assisted preoperative planning of reduction of and osteosynthesis of scapular fracture: A case report
title_short Computer-assisted preoperative planning of reduction of and osteosynthesis of scapular fracture: A case report
title_sort computer-assisted preoperative planning of reduction of and osteosynthesis of scapular fracture: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8546289/
https://www.ncbi.nlm.nih.gov/pubmed/34722895
http://dx.doi.org/10.1515/med-2021-0338
work_keys_str_mv AT madejaroman computerassistedpreoperativeplanningofreductionofandosteosynthesisofscapularfractureacasereport
AT bajorgrzegorz computerassistedpreoperativeplanningofreductionofandosteosynthesisofscapularfractureacasereport
AT klimaondrej computerassistedpreoperativeplanningofreductionofandosteosynthesisofscapularfractureacasereport
AT bialylubor computerassistedpreoperativeplanningofreductionofandosteosynthesisofscapularfractureacasereport
AT pometlovajana computerassistedpreoperativeplanningofreductionofandosteosynthesisofscapularfractureacasereport