Cargando…
Determination of oxygen saturation compared to a prescribed target range using continuous pulse oximetry in acutely unwell medical patients
BACKGROUND: Both inadequate and excessive administration of oxygen to acutely unwell patients results in risk of harm. Guidelines recommend titration of oxygen to achieve a target oxygen saturation (SpO(2)) range. Information regarding whether this is being achieved is limited. METHODS: In this two-...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8546386/ https://www.ncbi.nlm.nih.gov/pubmed/34702236 http://dx.doi.org/10.1186/s12890-021-01700-6 |
Sumario: | BACKGROUND: Both inadequate and excessive administration of oxygen to acutely unwell patients results in risk of harm. Guidelines recommend titration of oxygen to achieve a target oxygen saturation (SpO(2)) range. Information regarding whether this is being achieved is limited. METHODS: In this two-centre non-interventional study we used continuous pulse oximetry in acutely unwell medical patients over a 24-h period to determine the proportion of time spent with SpO(2) within the prescribed target range and whether this is influenced by the target range, age, care in a high-dependency area and the number of oxygen adjustments. RESULTS: Eighty participants were included in the analysis. The mean (SD) proportion of time spent in target range was 55.6% (23.6), this was lower in those with a reduced hypercapnic target range (88–92% or below) compared to those with a range of 92–96%; difference − 13.1% (95% CI − 3.0 to − 23.2), P = 0.012. The proportion of time spent above range was 16.2% (22.9); this was higher in those with a reduced hypercapnic range; difference 21.6% (31.4 to 12), P < 0.001. The proportion of time below range was 28.4% (25.2); there was no difference between target ranges. The proportion of time spent in range was higher for those in a high dependency area in the multivariate model; difference 15.5% (95% CI 2.3 to 28.7), P = 0.02. CONCLUSIONS: Medical patients receiving oxygen in a ward setting spend significant periods of time with SpO(2) both above and below the prescribed target range while receiving oxygen therapy. |
---|