Cargando…

Optimization of a protocol for contrast-enhanced four-dimensional computed tomography imaging of thoracic tumors using minimal contrast agent

PURPOSE: The accuracy of target delineation for node-positive thoracic tumors is dependent on both four-dimensional computed tomography (4D-CT) and contrast-enhanced three-dimensional (3D)-CT images; these scans enable the motion visualization of tumors and delineate the nodal areas. Combining the t...

Descripción completa

Detalles Bibliográficos
Autores principales: Dai, Hongya, Yang, Dingqiang, Chen, Lu, Zhou, Yibing, Wen, Xiaojing, Sun, Jianguo, Li, Guanghui
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8547213/
https://www.ncbi.nlm.nih.gov/pubmed/34476528
http://dx.doi.org/10.1007/s00066-021-01836-8
_version_ 1784590338127560704
author Dai, Hongya
Yang, Dingqiang
Chen, Lu
Zhou, Yibing
Wen, Xiaojing
Sun, Jianguo
Li, Guanghui
author_facet Dai, Hongya
Yang, Dingqiang
Chen, Lu
Zhou, Yibing
Wen, Xiaojing
Sun, Jianguo
Li, Guanghui
author_sort Dai, Hongya
collection PubMed
description PURPOSE: The accuracy of target delineation for node-positive thoracic tumors is dependent on both four-dimensional computed tomography (4D-CT) and contrast-enhanced three-dimensional (3D)-CT images; these scans enable the motion visualization of tumors and delineate the nodal areas. Combining the two techniques would be more effective; however, currently, there is no standard protocol for the contrast media injection parameters for contrast-enhanced 4D-CT (CE-4D-CT) scans because of its long scan durations and complexity. Thus, we aimed to perform quantitative and qualitative assessments of the image quality of single contrast-enhanced 4D-CT scans to simplify this process and improve the accuracy of target delineation in order to replace the standard clinical modality involved in administering radiotherapy for thoracic tumors. METHODS: Ninety consecutive patients with thoracic tumors were randomly and parallelly assigned to one of nine subgroups subjected to CE-4D-CT scans with the administration of contrast agent volume equal to the patient’s weight but different flow rate and scan delay time (protocol A1: flow rate of 2.0 ml/s, delay time of 15 s; A2: 2.0 ml/s, 20 s; A3: 2.0 ml/s, 25 s; B1: 2.5 ml/s, 15 s; B2: 2.5 ml/s, 20 s; B3: 2.5 ml/s, 25 s; C1: 3.0 ml/s, 15 s; C2: 3.0 ml/s, 20 s; C3: 3.0 ml/s, 25 s). The Hounsfield unit (HU) values of the thoracic aorta, pulmonary artery stem, pulmonary veins, carotid artery, and jugular vein were acquired for each protocol. Both quantitative and qualitative image analysis and delineation acceptability were assessed. RESULTS: The results revealed significant differences among the nine protocols. Enhancement of the vascular structures in mediastinal and perihilar regions was more effective with protocol A1 or A2; however, when interested in the region of superior mediastinum and supraclavicular fossa, protocol C2 or C3 is recommended. CONCLUSION: Qualitatively acceptable enhancement on contrast-enhanced 4D-CT images of thoracic tumors can be obtained by varying the flow rate and delay time when minimal contrast agent is used.
format Online
Article
Text
id pubmed-8547213
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-85472132021-10-29 Optimization of a protocol for contrast-enhanced four-dimensional computed tomography imaging of thoracic tumors using minimal contrast agent Dai, Hongya Yang, Dingqiang Chen, Lu Zhou, Yibing Wen, Xiaojing Sun, Jianguo Li, Guanghui Strahlenther Onkol Original Article PURPOSE: The accuracy of target delineation for node-positive thoracic tumors is dependent on both four-dimensional computed tomography (4D-CT) and contrast-enhanced three-dimensional (3D)-CT images; these scans enable the motion visualization of tumors and delineate the nodal areas. Combining the two techniques would be more effective; however, currently, there is no standard protocol for the contrast media injection parameters for contrast-enhanced 4D-CT (CE-4D-CT) scans because of its long scan durations and complexity. Thus, we aimed to perform quantitative and qualitative assessments of the image quality of single contrast-enhanced 4D-CT scans to simplify this process and improve the accuracy of target delineation in order to replace the standard clinical modality involved in administering radiotherapy for thoracic tumors. METHODS: Ninety consecutive patients with thoracic tumors were randomly and parallelly assigned to one of nine subgroups subjected to CE-4D-CT scans with the administration of contrast agent volume equal to the patient’s weight but different flow rate and scan delay time (protocol A1: flow rate of 2.0 ml/s, delay time of 15 s; A2: 2.0 ml/s, 20 s; A3: 2.0 ml/s, 25 s; B1: 2.5 ml/s, 15 s; B2: 2.5 ml/s, 20 s; B3: 2.5 ml/s, 25 s; C1: 3.0 ml/s, 15 s; C2: 3.0 ml/s, 20 s; C3: 3.0 ml/s, 25 s). The Hounsfield unit (HU) values of the thoracic aorta, pulmonary artery stem, pulmonary veins, carotid artery, and jugular vein were acquired for each protocol. Both quantitative and qualitative image analysis and delineation acceptability were assessed. RESULTS: The results revealed significant differences among the nine protocols. Enhancement of the vascular structures in mediastinal and perihilar regions was more effective with protocol A1 or A2; however, when interested in the region of superior mediastinum and supraclavicular fossa, protocol C2 or C3 is recommended. CONCLUSION: Qualitatively acceptable enhancement on contrast-enhanced 4D-CT images of thoracic tumors can be obtained by varying the flow rate and delay time when minimal contrast agent is used. Springer Berlin Heidelberg 2021-09-02 2021 /pmc/articles/PMC8547213/ /pubmed/34476528 http://dx.doi.org/10.1007/s00066-021-01836-8 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Dai, Hongya
Yang, Dingqiang
Chen, Lu
Zhou, Yibing
Wen, Xiaojing
Sun, Jianguo
Li, Guanghui
Optimization of a protocol for contrast-enhanced four-dimensional computed tomography imaging of thoracic tumors using minimal contrast agent
title Optimization of a protocol for contrast-enhanced four-dimensional computed tomography imaging of thoracic tumors using minimal contrast agent
title_full Optimization of a protocol for contrast-enhanced four-dimensional computed tomography imaging of thoracic tumors using minimal contrast agent
title_fullStr Optimization of a protocol for contrast-enhanced four-dimensional computed tomography imaging of thoracic tumors using minimal contrast agent
title_full_unstemmed Optimization of a protocol for contrast-enhanced four-dimensional computed tomography imaging of thoracic tumors using minimal contrast agent
title_short Optimization of a protocol for contrast-enhanced four-dimensional computed tomography imaging of thoracic tumors using minimal contrast agent
title_sort optimization of a protocol for contrast-enhanced four-dimensional computed tomography imaging of thoracic tumors using minimal contrast agent
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8547213/
https://www.ncbi.nlm.nih.gov/pubmed/34476528
http://dx.doi.org/10.1007/s00066-021-01836-8
work_keys_str_mv AT daihongya optimizationofaprotocolforcontrastenhancedfourdimensionalcomputedtomographyimagingofthoracictumorsusingminimalcontrastagent
AT yangdingqiang optimizationofaprotocolforcontrastenhancedfourdimensionalcomputedtomographyimagingofthoracictumorsusingminimalcontrastagent
AT chenlu optimizationofaprotocolforcontrastenhancedfourdimensionalcomputedtomographyimagingofthoracictumorsusingminimalcontrastagent
AT zhouyibing optimizationofaprotocolforcontrastenhancedfourdimensionalcomputedtomographyimagingofthoracictumorsusingminimalcontrastagent
AT wenxiaojing optimizationofaprotocolforcontrastenhancedfourdimensionalcomputedtomographyimagingofthoracictumorsusingminimalcontrastagent
AT sunjianguo optimizationofaprotocolforcontrastenhancedfourdimensionalcomputedtomographyimagingofthoracictumorsusingminimalcontrastagent
AT liguanghui optimizationofaprotocolforcontrastenhancedfourdimensionalcomputedtomographyimagingofthoracictumorsusingminimalcontrastagent