Cargando…

An ultrasensitive molecularly imprinted polymer-based electrochemical sensor for the determination of SARS-CoV-2-RBD by using macroporous gold screen-printed electrode

Herein, a novel molecularly imprinted polymer (MIP) based electrochemical sensor for the determination of the receptor-binding domain of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2-RBD) has been developed. For this purpose, first, a macroporous gold screen-printed electrode (MP-Au-SP...

Descripción completa

Detalles Bibliográficos
Autores principales: Amouzadeh Tabrizi, Mahmoud, Fernández-Blázquez, Juan P., Medina, Dahiana Mojena, Acedo, Pablo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier B.V. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8547854/
https://www.ncbi.nlm.nih.gov/pubmed/34736101
http://dx.doi.org/10.1016/j.bios.2021.113729
_version_ 1784590460755378176
author Amouzadeh Tabrizi, Mahmoud
Fernández-Blázquez, Juan P.
Medina, Dahiana Mojena
Acedo, Pablo
author_facet Amouzadeh Tabrizi, Mahmoud
Fernández-Blázquez, Juan P.
Medina, Dahiana Mojena
Acedo, Pablo
author_sort Amouzadeh Tabrizi, Mahmoud
collection PubMed
description Herein, a novel molecularly imprinted polymer (MIP) based electrochemical sensor for the determination of the receptor-binding domain of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2-RBD) has been developed. For this purpose, first, a macroporous gold screen-printed electrode (MP-Au-SPE) has been fabricated. The MIP was then synthesized on the surface of the MP-Au-SPE through the electro-polymerization of ortho-phenylenediamine in the presence of SARS-CoV-2-RBD molecules as matrix polymer, and template molecules, respectively. During the fabrication process, the SARS-CoV-2-RBD molecules were embedded in the polymer matrix. Subsequently, the template molecules were removed from the electrode by using alkaline ethanol. The template molecules removal was studied using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), scanning electron microscope (SEM), energy-dispersive X-ray spectroscopy (EDX), and attenuated total reflectance spectroscopy (ATR). The fabricated MIP film acted as an artificial recognition element for the measurement of SARS-CoV-2-RBD. The EIS technique was used for the measurement of the SARS-CoV-2-RBD in the saliva solution. The electron transfer resistance (R(et)) of the MIP-based sensor in a ferri/ferrocyanide solution increased as the SARS-CoV-2-RBD concentration increased due to the occupation of the imprinted cavities by the SARS-CoV-2-RBD. The MIP-based sensor exhibited a good response to the SARS-CoV-2-RBD in the concentration range between 2.0 and 40.0 pg mL(-1) with a limit of detection of 0.7 pg mL(-1). The obtained results showed that the fabricated MIP sensor has high selectivity sensitivity, and stability.
format Online
Article
Text
id pubmed-8547854
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier B.V.
record_format MEDLINE/PubMed
spelling pubmed-85478542021-10-27 An ultrasensitive molecularly imprinted polymer-based electrochemical sensor for the determination of SARS-CoV-2-RBD by using macroporous gold screen-printed electrode Amouzadeh Tabrizi, Mahmoud Fernández-Blázquez, Juan P. Medina, Dahiana Mojena Acedo, Pablo Biosens Bioelectron Article Herein, a novel molecularly imprinted polymer (MIP) based electrochemical sensor for the determination of the receptor-binding domain of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2-RBD) has been developed. For this purpose, first, a macroporous gold screen-printed electrode (MP-Au-SPE) has been fabricated. The MIP was then synthesized on the surface of the MP-Au-SPE through the electro-polymerization of ortho-phenylenediamine in the presence of SARS-CoV-2-RBD molecules as matrix polymer, and template molecules, respectively. During the fabrication process, the SARS-CoV-2-RBD molecules were embedded in the polymer matrix. Subsequently, the template molecules were removed from the electrode by using alkaline ethanol. The template molecules removal was studied using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), scanning electron microscope (SEM), energy-dispersive X-ray spectroscopy (EDX), and attenuated total reflectance spectroscopy (ATR). The fabricated MIP film acted as an artificial recognition element for the measurement of SARS-CoV-2-RBD. The EIS technique was used for the measurement of the SARS-CoV-2-RBD in the saliva solution. The electron transfer resistance (R(et)) of the MIP-based sensor in a ferri/ferrocyanide solution increased as the SARS-CoV-2-RBD concentration increased due to the occupation of the imprinted cavities by the SARS-CoV-2-RBD. The MIP-based sensor exhibited a good response to the SARS-CoV-2-RBD in the concentration range between 2.0 and 40.0 pg mL(-1) with a limit of detection of 0.7 pg mL(-1). The obtained results showed that the fabricated MIP sensor has high selectivity sensitivity, and stability. Elsevier B.V. 2022-01-15 2021-10-26 /pmc/articles/PMC8547854/ /pubmed/34736101 http://dx.doi.org/10.1016/j.bios.2021.113729 Text en © 2021 Elsevier B.V. All rights reserved. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active.
spellingShingle Article
Amouzadeh Tabrizi, Mahmoud
Fernández-Blázquez, Juan P.
Medina, Dahiana Mojena
Acedo, Pablo
An ultrasensitive molecularly imprinted polymer-based electrochemical sensor for the determination of SARS-CoV-2-RBD by using macroporous gold screen-printed electrode
title An ultrasensitive molecularly imprinted polymer-based electrochemical sensor for the determination of SARS-CoV-2-RBD by using macroporous gold screen-printed electrode
title_full An ultrasensitive molecularly imprinted polymer-based electrochemical sensor for the determination of SARS-CoV-2-RBD by using macroporous gold screen-printed electrode
title_fullStr An ultrasensitive molecularly imprinted polymer-based electrochemical sensor for the determination of SARS-CoV-2-RBD by using macroporous gold screen-printed electrode
title_full_unstemmed An ultrasensitive molecularly imprinted polymer-based electrochemical sensor for the determination of SARS-CoV-2-RBD by using macroporous gold screen-printed electrode
title_short An ultrasensitive molecularly imprinted polymer-based electrochemical sensor for the determination of SARS-CoV-2-RBD by using macroporous gold screen-printed electrode
title_sort ultrasensitive molecularly imprinted polymer-based electrochemical sensor for the determination of sars-cov-2-rbd by using macroporous gold screen-printed electrode
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8547854/
https://www.ncbi.nlm.nih.gov/pubmed/34736101
http://dx.doi.org/10.1016/j.bios.2021.113729
work_keys_str_mv AT amouzadehtabrizimahmoud anultrasensitivemolecularlyimprintedpolymerbasedelectrochemicalsensorforthedeterminationofsarscov2rbdbyusingmacroporousgoldscreenprintedelectrode
AT fernandezblazquezjuanp anultrasensitivemolecularlyimprintedpolymerbasedelectrochemicalsensorforthedeterminationofsarscov2rbdbyusingmacroporousgoldscreenprintedelectrode
AT medinadahianamojena anultrasensitivemolecularlyimprintedpolymerbasedelectrochemicalsensorforthedeterminationofsarscov2rbdbyusingmacroporousgoldscreenprintedelectrode
AT acedopablo anultrasensitivemolecularlyimprintedpolymerbasedelectrochemicalsensorforthedeterminationofsarscov2rbdbyusingmacroporousgoldscreenprintedelectrode
AT amouzadehtabrizimahmoud ultrasensitivemolecularlyimprintedpolymerbasedelectrochemicalsensorforthedeterminationofsarscov2rbdbyusingmacroporousgoldscreenprintedelectrode
AT fernandezblazquezjuanp ultrasensitivemolecularlyimprintedpolymerbasedelectrochemicalsensorforthedeterminationofsarscov2rbdbyusingmacroporousgoldscreenprintedelectrode
AT medinadahianamojena ultrasensitivemolecularlyimprintedpolymerbasedelectrochemicalsensorforthedeterminationofsarscov2rbdbyusingmacroporousgoldscreenprintedelectrode
AT acedopablo ultrasensitivemolecularlyimprintedpolymerbasedelectrochemicalsensorforthedeterminationofsarscov2rbdbyusingmacroporousgoldscreenprintedelectrode