Cargando…

Spatial Resolution of Suprachoroidal–Transretinal Stimulation Estimated by Recording Single-Unit Activity From the Cat Lateral Geniculate Nucleus

Retinal prostheses are devices used to restore visual sensation in patients suffering from photoreceptor degeneration, such as retinitis pigmentosa. Suprachoroidal–transretinal stimulation (STS) is a prosthesis with retinal electrodes located in the sclera. STS has the advantage that it is safer tha...

Descripción completa

Detalles Bibliográficos
Autores principales: Miyoshi, Tomomitsu, Morimoto, Takeshi, Sawai, Hajime, Fujikado, Takashi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8549691/
https://www.ncbi.nlm.nih.gov/pubmed/34720855
http://dx.doi.org/10.3389/fnins.2021.717429
_version_ 1784590820366614528
author Miyoshi, Tomomitsu
Morimoto, Takeshi
Sawai, Hajime
Fujikado, Takashi
author_facet Miyoshi, Tomomitsu
Morimoto, Takeshi
Sawai, Hajime
Fujikado, Takashi
author_sort Miyoshi, Tomomitsu
collection PubMed
description Retinal prostheses are devices used to restore visual sensation in patients suffering from photoreceptor degeneration, such as retinitis pigmentosa. Suprachoroidal–transretinal stimulation (STS) is a prosthesis with retinal electrodes located in the sclera. STS has the advantage that it is safer than epiretinal or subretinal prostheses, as the implant is not directly attached to the retinal tissue. We have previously reported feasibility of STS with animal experiments and clinical trials. However, functional evaluation with neurophysiological experiments is still largely missing. To estimate the spatial resolution of STS, single-unit activities in response to STS were recorded from relay cells in the dorsal lateral geniculate nucleus of cats, and the response probability of the units was analyzed in relation to the distance between the stimulus location and the receptive field of each recorded unit. A platinum electrode was attached to the sclera after lamellar resection, and the return electrode was placed in the vitreous. The stimulating current, which ranged from 50 to 500 μA, was applied between these electrodes, and the probability of spike responses occurring just after retinal stimulation was measured. The distance at half-maximum of response was determined from the collected response probabilities as a function of stimulus intensity for all units characterized by their distances from the receptive field center to the stimulation point. As the stimulation became weaker, this distance decreased to 1.8° at 150 and 100 μA. As another estimation, the radius of 25% response probability was 1.4° at 100 μA. The diameter of the stimulated cat retinal area, 3.6° or 2.8°, corresponds to human visual acuity of 0.005 or 0.007, or finger counting. Considering the lower hazard to the retina of STS and its potentially large visual field coverage, STS is an attractive method for retinal prosthetic device development.
format Online
Article
Text
id pubmed-8549691
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-85496912021-10-28 Spatial Resolution of Suprachoroidal–Transretinal Stimulation Estimated by Recording Single-Unit Activity From the Cat Lateral Geniculate Nucleus Miyoshi, Tomomitsu Morimoto, Takeshi Sawai, Hajime Fujikado, Takashi Front Neurosci Neuroscience Retinal prostheses are devices used to restore visual sensation in patients suffering from photoreceptor degeneration, such as retinitis pigmentosa. Suprachoroidal–transretinal stimulation (STS) is a prosthesis with retinal electrodes located in the sclera. STS has the advantage that it is safer than epiretinal or subretinal prostheses, as the implant is not directly attached to the retinal tissue. We have previously reported feasibility of STS with animal experiments and clinical trials. However, functional evaluation with neurophysiological experiments is still largely missing. To estimate the spatial resolution of STS, single-unit activities in response to STS were recorded from relay cells in the dorsal lateral geniculate nucleus of cats, and the response probability of the units was analyzed in relation to the distance between the stimulus location and the receptive field of each recorded unit. A platinum electrode was attached to the sclera after lamellar resection, and the return electrode was placed in the vitreous. The stimulating current, which ranged from 50 to 500 μA, was applied between these electrodes, and the probability of spike responses occurring just after retinal stimulation was measured. The distance at half-maximum of response was determined from the collected response probabilities as a function of stimulus intensity for all units characterized by their distances from the receptive field center to the stimulation point. As the stimulation became weaker, this distance decreased to 1.8° at 150 and 100 μA. As another estimation, the radius of 25% response probability was 1.4° at 100 μA. The diameter of the stimulated cat retinal area, 3.6° or 2.8°, corresponds to human visual acuity of 0.005 or 0.007, or finger counting. Considering the lower hazard to the retina of STS and its potentially large visual field coverage, STS is an attractive method for retinal prosthetic device development. Frontiers Media S.A. 2021-10-13 /pmc/articles/PMC8549691/ /pubmed/34720855 http://dx.doi.org/10.3389/fnins.2021.717429 Text en Copyright © 2021 Miyoshi, Morimoto, Sawai and Fujikado. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neuroscience
Miyoshi, Tomomitsu
Morimoto, Takeshi
Sawai, Hajime
Fujikado, Takashi
Spatial Resolution of Suprachoroidal–Transretinal Stimulation Estimated by Recording Single-Unit Activity From the Cat Lateral Geniculate Nucleus
title Spatial Resolution of Suprachoroidal–Transretinal Stimulation Estimated by Recording Single-Unit Activity From the Cat Lateral Geniculate Nucleus
title_full Spatial Resolution of Suprachoroidal–Transretinal Stimulation Estimated by Recording Single-Unit Activity From the Cat Lateral Geniculate Nucleus
title_fullStr Spatial Resolution of Suprachoroidal–Transretinal Stimulation Estimated by Recording Single-Unit Activity From the Cat Lateral Geniculate Nucleus
title_full_unstemmed Spatial Resolution of Suprachoroidal–Transretinal Stimulation Estimated by Recording Single-Unit Activity From the Cat Lateral Geniculate Nucleus
title_short Spatial Resolution of Suprachoroidal–Transretinal Stimulation Estimated by Recording Single-Unit Activity From the Cat Lateral Geniculate Nucleus
title_sort spatial resolution of suprachoroidal–transretinal stimulation estimated by recording single-unit activity from the cat lateral geniculate nucleus
topic Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8549691/
https://www.ncbi.nlm.nih.gov/pubmed/34720855
http://dx.doi.org/10.3389/fnins.2021.717429
work_keys_str_mv AT miyoshitomomitsu spatialresolutionofsuprachoroidaltransretinalstimulationestimatedbyrecordingsingleunitactivityfromthecatlateralgeniculatenucleus
AT morimototakeshi spatialresolutionofsuprachoroidaltransretinalstimulationestimatedbyrecordingsingleunitactivityfromthecatlateralgeniculatenucleus
AT sawaihajime spatialresolutionofsuprachoroidaltransretinalstimulationestimatedbyrecordingsingleunitactivityfromthecatlateralgeniculatenucleus
AT fujikadotakashi spatialresolutionofsuprachoroidaltransretinalstimulationestimatedbyrecordingsingleunitactivityfromthecatlateralgeniculatenucleus