Cargando…

Hypochlorous Acid-Generating Electrochemical Catheter Prototype for Prevention of Intraluminal Infection

Central line-associated bloodstream infection (CLABSI) contributes to mortality and cost. While aseptic dressings and antibiotic-impregnated catheters prevent some extraluminal infections, intraluminal infections remain a source of CLABSIs. In this proof-of-concept study, an electrochemical intravas...

Descripción completa

Detalles Bibliográficos
Autores principales: Cano, Edison J., Flurin, Laure, Mohamed, Abdelrhman, Greenwood-Quaintance, Kerryl E., Raval, Yash S., Beyenal, Haluk, Patel, Robin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Society for Microbiology 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8549727/
https://www.ncbi.nlm.nih.gov/pubmed/34704827
http://dx.doi.org/10.1128/Spectrum.00557-21
_version_ 1784590826492395520
author Cano, Edison J.
Flurin, Laure
Mohamed, Abdelrhman
Greenwood-Quaintance, Kerryl E.
Raval, Yash S.
Beyenal, Haluk
Patel, Robin
author_facet Cano, Edison J.
Flurin, Laure
Mohamed, Abdelrhman
Greenwood-Quaintance, Kerryl E.
Raval, Yash S.
Beyenal, Haluk
Patel, Robin
author_sort Cano, Edison J.
collection PubMed
description Central line-associated bloodstream infection (CLABSI) contributes to mortality and cost. While aseptic dressings and antibiotic-impregnated catheters prevent some extraluminal infections, intraluminal infections remain a source of CLABSIs. In this proof-of-concept study, an electrochemical intravascular catheter (e-catheter) prototype capable of electrochemically generating hypochlorous acid intraluminally using platinum electrodes polarized at a constant potential of 1.5 electrode potential relative to saturated silver/silver chloride reference electrode measured in volts (V(Ag/AgCl)) was developed. After 24 h of prepolarization at 1.5 V(Ag/AgCl), their activity was tested against clinical isolates of Staphylococcus aureus, Staphylococcus epidermidis, Enterococcus faecium, and Escherichia coli derived from catheter-related infections. e-catheters generated a mean HOCl concentration of 15.86 ± 4.03 μM and had a mean pH of 6.14 ± 0.79. E-catheters prevented infections of all four species, with an average reduction of 8.41 ± 0.61 log(10) CFU/ml at 48 h compared to controls. Polarized e-catheters which generate low amounts of HOCl continuously should be further developed to prevent intraluminal infection. IMPORTANCE Catheter-related infections constitute an economic and mortality burden in health care. Several options are available to reduce the risk of infection, but only a few focus on preventing intraluminal infection, which occurs in long-term catheters, most often used for dialysis, prolonged treatment, or chemotherapy. A prototype of a catheter called an “e-catheter” composed of three electrodes, capable of producing hypochlorous acid (HOCl) electrochemically in its lumen, was developed. When polarized at 1.5 V, chloride ions in the solution are oxidized to continuously produce low amounts of HOCl, which exhibits antibacterial activity in the lumen of the catheter. Here, this prototype was shown to be able to generate HOCl as well as prevent infection in a preliminary in vitro catheter model. This approach is a potential strategy for catheter infection prevention.
format Online
Article
Text
id pubmed-8549727
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher American Society for Microbiology
record_format MEDLINE/PubMed
spelling pubmed-85497272021-11-08 Hypochlorous Acid-Generating Electrochemical Catheter Prototype for Prevention of Intraluminal Infection Cano, Edison J. Flurin, Laure Mohamed, Abdelrhman Greenwood-Quaintance, Kerryl E. Raval, Yash S. Beyenal, Haluk Patel, Robin Microbiol Spectr Research Article Central line-associated bloodstream infection (CLABSI) contributes to mortality and cost. While aseptic dressings and antibiotic-impregnated catheters prevent some extraluminal infections, intraluminal infections remain a source of CLABSIs. In this proof-of-concept study, an electrochemical intravascular catheter (e-catheter) prototype capable of electrochemically generating hypochlorous acid intraluminally using platinum electrodes polarized at a constant potential of 1.5 electrode potential relative to saturated silver/silver chloride reference electrode measured in volts (V(Ag/AgCl)) was developed. After 24 h of prepolarization at 1.5 V(Ag/AgCl), their activity was tested against clinical isolates of Staphylococcus aureus, Staphylococcus epidermidis, Enterococcus faecium, and Escherichia coli derived from catheter-related infections. e-catheters generated a mean HOCl concentration of 15.86 ± 4.03 μM and had a mean pH of 6.14 ± 0.79. E-catheters prevented infections of all four species, with an average reduction of 8.41 ± 0.61 log(10) CFU/ml at 48 h compared to controls. Polarized e-catheters which generate low amounts of HOCl continuously should be further developed to prevent intraluminal infection. IMPORTANCE Catheter-related infections constitute an economic and mortality burden in health care. Several options are available to reduce the risk of infection, but only a few focus on preventing intraluminal infection, which occurs in long-term catheters, most often used for dialysis, prolonged treatment, or chemotherapy. A prototype of a catheter called an “e-catheter” composed of three electrodes, capable of producing hypochlorous acid (HOCl) electrochemically in its lumen, was developed. When polarized at 1.5 V, chloride ions in the solution are oxidized to continuously produce low amounts of HOCl, which exhibits antibacterial activity in the lumen of the catheter. Here, this prototype was shown to be able to generate HOCl as well as prevent infection in a preliminary in vitro catheter model. This approach is a potential strategy for catheter infection prevention. American Society for Microbiology 2021-10-27 /pmc/articles/PMC8549727/ /pubmed/34704827 http://dx.doi.org/10.1128/Spectrum.00557-21 Text en Copyright © 2021 Cano et al. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution 4.0 International license (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Research Article
Cano, Edison J.
Flurin, Laure
Mohamed, Abdelrhman
Greenwood-Quaintance, Kerryl E.
Raval, Yash S.
Beyenal, Haluk
Patel, Robin
Hypochlorous Acid-Generating Electrochemical Catheter Prototype for Prevention of Intraluminal Infection
title Hypochlorous Acid-Generating Electrochemical Catheter Prototype for Prevention of Intraluminal Infection
title_full Hypochlorous Acid-Generating Electrochemical Catheter Prototype for Prevention of Intraluminal Infection
title_fullStr Hypochlorous Acid-Generating Electrochemical Catheter Prototype for Prevention of Intraluminal Infection
title_full_unstemmed Hypochlorous Acid-Generating Electrochemical Catheter Prototype for Prevention of Intraluminal Infection
title_short Hypochlorous Acid-Generating Electrochemical Catheter Prototype for Prevention of Intraluminal Infection
title_sort hypochlorous acid-generating electrochemical catheter prototype for prevention of intraluminal infection
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8549727/
https://www.ncbi.nlm.nih.gov/pubmed/34704827
http://dx.doi.org/10.1128/Spectrum.00557-21
work_keys_str_mv AT canoedisonj hypochlorousacidgeneratingelectrochemicalcatheterprototypeforpreventionofintraluminalinfection
AT flurinlaure hypochlorousacidgeneratingelectrochemicalcatheterprototypeforpreventionofintraluminalinfection
AT mohamedabdelrhman hypochlorousacidgeneratingelectrochemicalcatheterprototypeforpreventionofintraluminalinfection
AT greenwoodquaintancekerryle hypochlorousacidgeneratingelectrochemicalcatheterprototypeforpreventionofintraluminalinfection
AT ravalyashs hypochlorousacidgeneratingelectrochemicalcatheterprototypeforpreventionofintraluminalinfection
AT beyenalhaluk hypochlorousacidgeneratingelectrochemicalcatheterprototypeforpreventionofintraluminalinfection
AT patelrobin hypochlorousacidgeneratingelectrochemicalcatheterprototypeforpreventionofintraluminalinfection