Exposure to respirable dust among workers fabricating aluminium trihydroxide-containing synthetic countertops

The aim of this study is to characterize personal exposure of workers to respirable particulate matter (PM) generated in cutting and other fabrication activities when fabricating acryl polymer/aluminium trihydroxide synthetic countertops. We collected 29 personal full-day samples of respirable PM fr...

Descripción completa

Detalles Bibliográficos
Autores principales: Vinnikov, Denis, Blanc, Paul D., Raushanova, Aizhan, Beisbekova, Arailym, Abraham, Jerrold L., Zlobina, Yelena
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8551245/
https://www.ncbi.nlm.nih.gov/pubmed/34707188
http://dx.doi.org/10.1038/s41598-021-00814-5
_version_ 1784591114759569408
author Vinnikov, Denis
Blanc, Paul D.
Raushanova, Aizhan
Beisbekova, Arailym
Abraham, Jerrold L.
Zlobina, Yelena
author_facet Vinnikov, Denis
Blanc, Paul D.
Raushanova, Aizhan
Beisbekova, Arailym
Abraham, Jerrold L.
Zlobina, Yelena
author_sort Vinnikov, Denis
collection PubMed
description The aim of this study is to characterize personal exposure of workers to respirable particulate matter (PM) generated in cutting and other fabrication activities when fabricating acryl polymer/aluminium trihydroxide synthetic countertops. We collected 29 personal full-day samples of respirable PM from three workers in a small private workshop. We tested differences between- and within-worker variances of mass concentrations using the Kruskall-Wallis test. We used segmented regression to test the means and medians 15-min interval concentrations changes over time and to identify a breakpoint. Respirable PM concentrations ranged nearly 100-fold, from 0.280 to 25.4 mg/m(3) with a median of 2.0 mg/m(3) (1-min concentrations from 13,920 data points). There were no statistical difference in daily median or geometric mean concentrations among workers, whereas the concentrations were significantly higher on days with three versus two workers present. The 15-min median concentrations (n = 974 measures) increased until 2.35 h (beta 0.177; p < 0.05), representing a 0.70 mg increase in exposure per hour. This was followed by a plateau in concentrations. The high levels of respirable PM we observed among workers fabricating aluminium trihydroxide-containing synthetic countertops highlight an unmet early prevention need.
format Online
Article
Text
id pubmed-8551245
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-85512452021-10-28 Exposure to respirable dust among workers fabricating aluminium trihydroxide-containing synthetic countertops Vinnikov, Denis Blanc, Paul D. Raushanova, Aizhan Beisbekova, Arailym Abraham, Jerrold L. Zlobina, Yelena Sci Rep Article The aim of this study is to characterize personal exposure of workers to respirable particulate matter (PM) generated in cutting and other fabrication activities when fabricating acryl polymer/aluminium trihydroxide synthetic countertops. We collected 29 personal full-day samples of respirable PM from three workers in a small private workshop. We tested differences between- and within-worker variances of mass concentrations using the Kruskall-Wallis test. We used segmented regression to test the means and medians 15-min interval concentrations changes over time and to identify a breakpoint. Respirable PM concentrations ranged nearly 100-fold, from 0.280 to 25.4 mg/m(3) with a median of 2.0 mg/m(3) (1-min concentrations from 13,920 data points). There were no statistical difference in daily median or geometric mean concentrations among workers, whereas the concentrations were significantly higher on days with three versus two workers present. The 15-min median concentrations (n = 974 measures) increased until 2.35 h (beta 0.177; p < 0.05), representing a 0.70 mg increase in exposure per hour. This was followed by a plateau in concentrations. The high levels of respirable PM we observed among workers fabricating aluminium trihydroxide-containing synthetic countertops highlight an unmet early prevention need. Nature Publishing Group UK 2021-10-27 /pmc/articles/PMC8551245/ /pubmed/34707188 http://dx.doi.org/10.1038/s41598-021-00814-5 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Vinnikov, Denis
Blanc, Paul D.
Raushanova, Aizhan
Beisbekova, Arailym
Abraham, Jerrold L.
Zlobina, Yelena
Exposure to respirable dust among workers fabricating aluminium trihydroxide-containing synthetic countertops
title Exposure to respirable dust among workers fabricating aluminium trihydroxide-containing synthetic countertops
title_full Exposure to respirable dust among workers fabricating aluminium trihydroxide-containing synthetic countertops
title_fullStr Exposure to respirable dust among workers fabricating aluminium trihydroxide-containing synthetic countertops
title_full_unstemmed Exposure to respirable dust among workers fabricating aluminium trihydroxide-containing synthetic countertops
title_short Exposure to respirable dust among workers fabricating aluminium trihydroxide-containing synthetic countertops
title_sort exposure to respirable dust among workers fabricating aluminium trihydroxide-containing synthetic countertops
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8551245/
https://www.ncbi.nlm.nih.gov/pubmed/34707188
http://dx.doi.org/10.1038/s41598-021-00814-5
work_keys_str_mv AT vinnikovdenis exposuretorespirabledustamongworkersfabricatingaluminiumtrihydroxidecontainingsyntheticcountertops
AT blancpauld exposuretorespirabledustamongworkersfabricatingaluminiumtrihydroxidecontainingsyntheticcountertops
AT raushanovaaizhan exposuretorespirabledustamongworkersfabricatingaluminiumtrihydroxidecontainingsyntheticcountertops
AT beisbekovaarailym exposuretorespirabledustamongworkersfabricatingaluminiumtrihydroxidecontainingsyntheticcountertops
AT abrahamjerroldl exposuretorespirabledustamongworkersfabricatingaluminiumtrihydroxidecontainingsyntheticcountertops
AT zlobinayelena exposuretorespirabledustamongworkersfabricatingaluminiumtrihydroxidecontainingsyntheticcountertops