Difficulty removing a leadless pacemaker in a post-transfusion patient

A 99-year-old woman with atrial fibrillation bradycardia and symptomatic long pauses underwent a leadless pacemaker implantation after red blood cell transfusion due to anaemia. The patient’s blood tests after transfusion showed hypercoagulability; haematocrit, haemoglobin and fibrinogen levels were...

Descripción completa

Detalles Bibliográficos
Autores principales: Tajima, Atomu, Mizutani, Yoshiaki, Kanasiro, Masaaki, Amano, Tetsuya
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8552136/
https://www.ncbi.nlm.nih.gov/pubmed/34706922
http://dx.doi.org/10.1136/bcr-2021-246625
_version_ 1784591317522710528
author Tajima, Atomu
Mizutani, Yoshiaki
Kanasiro, Masaaki
Amano, Tetsuya
author_facet Tajima, Atomu
Mizutani, Yoshiaki
Kanasiro, Masaaki
Amano, Tetsuya
author_sort Tajima, Atomu
collection PubMed
description A 99-year-old woman with atrial fibrillation bradycardia and symptomatic long pauses underwent a leadless pacemaker implantation after red blood cell transfusion due to anaemia. The patient’s blood tests after transfusion showed hypercoagulability; haematocrit, haemoglobin and fibrinogen levels were increased from 24.5% to 33.2%, 76 g/L to 111g/L, and 346 mg/dL to 646 mg/dL, respectively. Blood tests showed no hereditary hypercoagulability disorder and she had no history of thrombophilia. A leadless pacemaker was implanted in the correct position in the right ventricle. Heparin was administered after sheath insertion and the leadless pacemaker system was thoroughly flushed with heparinised saline before the tether was cut; however, removing the tether after leadless pacemaker implantation was difficult because clots had formed on the tether.
format Online
Article
Text
id pubmed-8552136
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-85521362021-11-10 Difficulty removing a leadless pacemaker in a post-transfusion patient Tajima, Atomu Mizutani, Yoshiaki Kanasiro, Masaaki Amano, Tetsuya BMJ Case Rep Case Report A 99-year-old woman with atrial fibrillation bradycardia and symptomatic long pauses underwent a leadless pacemaker implantation after red blood cell transfusion due to anaemia. The patient’s blood tests after transfusion showed hypercoagulability; haematocrit, haemoglobin and fibrinogen levels were increased from 24.5% to 33.2%, 76 g/L to 111g/L, and 346 mg/dL to 646 mg/dL, respectively. Blood tests showed no hereditary hypercoagulability disorder and she had no history of thrombophilia. A leadless pacemaker was implanted in the correct position in the right ventricle. Heparin was administered after sheath insertion and the leadless pacemaker system was thoroughly flushed with heparinised saline before the tether was cut; however, removing the tether after leadless pacemaker implantation was difficult because clots had formed on the tether. BMJ Publishing Group 2021-10-27 /pmc/articles/PMC8552136/ /pubmed/34706922 http://dx.doi.org/10.1136/bcr-2021-246625 Text en © BMJ Publishing Group Limited 2021. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) .
spellingShingle Case Report
Tajima, Atomu
Mizutani, Yoshiaki
Kanasiro, Masaaki
Amano, Tetsuya
Difficulty removing a leadless pacemaker in a post-transfusion patient
title Difficulty removing a leadless pacemaker in a post-transfusion patient
title_full Difficulty removing a leadless pacemaker in a post-transfusion patient
title_fullStr Difficulty removing a leadless pacemaker in a post-transfusion patient
title_full_unstemmed Difficulty removing a leadless pacemaker in a post-transfusion patient
title_short Difficulty removing a leadless pacemaker in a post-transfusion patient
title_sort difficulty removing a leadless pacemaker in a post-transfusion patient
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8552136/
https://www.ncbi.nlm.nih.gov/pubmed/34706922
http://dx.doi.org/10.1136/bcr-2021-246625
work_keys_str_mv AT tajimaatomu difficultyremovingaleadlesspacemakerinaposttransfusionpatient
AT mizutaniyoshiaki difficultyremovingaleadlesspacemakerinaposttransfusionpatient
AT kanasiromasaaki difficultyremovingaleadlesspacemakerinaposttransfusionpatient
AT amanotetsuya difficultyremovingaleadlesspacemakerinaposttransfusionpatient