Cargando…
Performance Evaluation of the MatMaCorp COVID-19 2SF Assay for the Detection of SARS-CoV-2 from Nasopharyngeal Swabs
The coronavirus disease 2019 (COVID-19) pandemic has taken an unprecedented toll on clinical diagnostic testing, and the need for PCR-based testing remains to be met. Nucleic acid amplification testing (NAAT) is the recommended method for the diagnosis of severe acute respiratory syndrome coronaviru...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Society for Microbiology
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8552687/ https://www.ncbi.nlm.nih.gov/pubmed/34378961 http://dx.doi.org/10.1128/spectrum.00083-21 |
Sumario: | The coronavirus disease 2019 (COVID-19) pandemic has taken an unprecedented toll on clinical diagnostic testing, and the need for PCR-based testing remains to be met. Nucleic acid amplification testing (NAAT) is the recommended method for the diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) due to the inherent advantages in sensitivity and specificity. In this study, we evaluated the performance of the MatMaCorp COVID-19 2SF test, a reverse transcription-PCR (RT-PCR) assay for the qualitative detection of SARS-CoV-2 from nasopharyngeal (NP) swabs, run on the Solas 8 instrument (MatMaCorp, Lincoln, NE). The Solas 8 device is portable, and the kit is a lab-in-a-box design which provides reagents in a shelf-stable lyophilized powder format. A total of 78 remnant clinical specimens were used to evaluate the COVID-19 2SF test. Sixty-two clinical specimens originally tested by the Xpert Xpress SARS-CoV-2 assay (Cepheid, Inc., Sunnyvale, CA) were used to evaluate the clinical accuracy of the COVID-19 2SF test. The negative percent agreement (NPA) was 100% (95% confidence interval [CI], 83.9% to 100%), and the positive percent agreement (PPA) was 85.4% (95% CI, 70.8% to 94.4%). Sixteen remnant specimens positive for other common respiratory pathogens (FilmArray respiratory panel 2.0; BioFire, Salt Lake City, UT) were assayed on the Solas 8 device to evaluate specificity. No cross-reactivity with other respiratory pathogens was identified. The unique lab-in-a-box design and shelf-stable reagents of the MatMaCorp COVID-19 2SF test offer laboratories a rapid option for a diagnostic NAAT for SARS-CoV-2 that can help meet diagnostic needs. IMPORTANCE The demand for molecular testing for COVID-19 remains to be met. This study of the MatMaCorp Solas 8 device and COVID-19 test provides the first evaluation of this platform. |
---|