Cargando…

Optical coherence tomography monitoring and diagnosing retinal changes in multiple sclerosis

This study explores the use of optical coherence tomography (OCT) to monitor and diagnose multiple sclerosis (MS). The analysis of reduced total macular volume and peripapillary retinal nerve fiber layer thinning are shown. The severity of these defects increases as MS progresses, reflecting the pro...

Descripción completa

Detalles Bibliográficos
Autores principales: Mehmood, Arshad, Ali, Wajid, Song, Shuang, Din, Zaheer Ud, Guo, Ruo‐Yi, Shah, Wahid, Ilahi, Ikram, Yin, Bowen, Yan, Hongjing, Zhang, Lu, Khan, Murad, Zeb, Liaqat, Safari, Hamidreza, Li, Bin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8553325/
https://www.ncbi.nlm.nih.gov/pubmed/34520634
http://dx.doi.org/10.1002/brb3.2302
_version_ 1784591556167073792
author Mehmood, Arshad
Ali, Wajid
Song, Shuang
Din, Zaheer Ud
Guo, Ruo‐Yi
Shah, Wahid
Ilahi, Ikram
Yin, Bowen
Yan, Hongjing
Zhang, Lu
Khan, Murad
Ali, Wajid
Zeb, Liaqat
Safari, Hamidreza
Li, Bin
author_facet Mehmood, Arshad
Ali, Wajid
Song, Shuang
Din, Zaheer Ud
Guo, Ruo‐Yi
Shah, Wahid
Ilahi, Ikram
Yin, Bowen
Yan, Hongjing
Zhang, Lu
Khan, Murad
Ali, Wajid
Zeb, Liaqat
Safari, Hamidreza
Li, Bin
author_sort Mehmood, Arshad
collection PubMed
description This study explores the use of optical coherence tomography (OCT) to monitor and diagnose multiple sclerosis (MS). The analysis of reduced total macular volume and peripapillary retinal nerve fiber layer thinning are shown. The severity of these defects increases as MS progresses, reflecting the progressive degeneration of nerve fibers and retinal ganglion cells. The OCT parameters are noninvasive, sensitive indicators that can be used to assess the progression of neurodegeneration and inflammation in MS.
format Online
Article
Text
id pubmed-8553325
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-85533252021-11-04 Optical coherence tomography monitoring and diagnosing retinal changes in multiple sclerosis Mehmood, Arshad Ali, Wajid Song, Shuang Din, Zaheer Ud Guo, Ruo‐Yi Shah, Wahid Ilahi, Ikram Yin, Bowen Yan, Hongjing Zhang, Lu Khan, Murad Ali, Wajid Zeb, Liaqat Safari, Hamidreza Li, Bin Brain Behav Review This study explores the use of optical coherence tomography (OCT) to monitor and diagnose multiple sclerosis (MS). The analysis of reduced total macular volume and peripapillary retinal nerve fiber layer thinning are shown. The severity of these defects increases as MS progresses, reflecting the progressive degeneration of nerve fibers and retinal ganglion cells. The OCT parameters are noninvasive, sensitive indicators that can be used to assess the progression of neurodegeneration and inflammation in MS. John Wiley and Sons Inc. 2021-09-14 /pmc/articles/PMC8553325/ /pubmed/34520634 http://dx.doi.org/10.1002/brb3.2302 Text en © 2021 The Authors. Brain and Behavior published by Wiley Periodicals LLC https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Review
Mehmood, Arshad
Ali, Wajid
Song, Shuang
Din, Zaheer Ud
Guo, Ruo‐Yi
Shah, Wahid
Ilahi, Ikram
Yin, Bowen
Yan, Hongjing
Zhang, Lu
Khan, Murad
Ali, Wajid
Zeb, Liaqat
Safari, Hamidreza
Li, Bin
Optical coherence tomography monitoring and diagnosing retinal changes in multiple sclerosis
title Optical coherence tomography monitoring and diagnosing retinal changes in multiple sclerosis
title_full Optical coherence tomography monitoring and diagnosing retinal changes in multiple sclerosis
title_fullStr Optical coherence tomography monitoring and diagnosing retinal changes in multiple sclerosis
title_full_unstemmed Optical coherence tomography monitoring and diagnosing retinal changes in multiple sclerosis
title_short Optical coherence tomography monitoring and diagnosing retinal changes in multiple sclerosis
title_sort optical coherence tomography monitoring and diagnosing retinal changes in multiple sclerosis
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8553325/
https://www.ncbi.nlm.nih.gov/pubmed/34520634
http://dx.doi.org/10.1002/brb3.2302
work_keys_str_mv AT mehmoodarshad opticalcoherencetomographymonitoringanddiagnosingretinalchangesinmultiplesclerosis
AT aliwajid opticalcoherencetomographymonitoringanddiagnosingretinalchangesinmultiplesclerosis
AT songshuang opticalcoherencetomographymonitoringanddiagnosingretinalchangesinmultiplesclerosis
AT dinzaheerud opticalcoherencetomographymonitoringanddiagnosingretinalchangesinmultiplesclerosis
AT guoruoyi opticalcoherencetomographymonitoringanddiagnosingretinalchangesinmultiplesclerosis
AT shahwahid opticalcoherencetomographymonitoringanddiagnosingretinalchangesinmultiplesclerosis
AT ilahiikram opticalcoherencetomographymonitoringanddiagnosingretinalchangesinmultiplesclerosis
AT yinbowen opticalcoherencetomographymonitoringanddiagnosingretinalchangesinmultiplesclerosis
AT yanhongjing opticalcoherencetomographymonitoringanddiagnosingretinalchangesinmultiplesclerosis
AT zhanglu opticalcoherencetomographymonitoringanddiagnosingretinalchangesinmultiplesclerosis
AT khanmurad opticalcoherencetomographymonitoringanddiagnosingretinalchangesinmultiplesclerosis
AT aliwajid opticalcoherencetomographymonitoringanddiagnosingretinalchangesinmultiplesclerosis
AT zebliaqat opticalcoherencetomographymonitoringanddiagnosingretinalchangesinmultiplesclerosis
AT safarihamidreza opticalcoherencetomographymonitoringanddiagnosingretinalchangesinmultiplesclerosis
AT libin opticalcoherencetomographymonitoringanddiagnosingretinalchangesinmultiplesclerosis